SciELO - Scientific Electronic Library Online

 
vol.19 issue2Cardiac resynchronization device implantation via the femoral artery: An alternative to difficult subclavian access author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Revista Colombiana de Cardiología

Print version ISSN 0120-5633

Abstract

BALPARDA, Jon Kepa et al. Non-invasive hemodynamic evaluation with impedance cardiography: applications in heart failure and hypertension. Rev. Colomb. Cardiol. [online]. 2012, vol.19, n.2, pp.82-90. ISSN 0120-5633.

Impedance cardiography (ICG) represents a non-invasive method for hemodynamic assessment in a beat-to-beat basis. Since its introduction more than forty years ago, a renewed interest in the use of this technique during the last decade has been noticed, mainly as a result of a series of clinical studies showing its precision in the estimation of stroke volume either against invasive gold standard (i.e. thermodilution) or against non-invasive reference methods (i.e. echocardiography). On the other hand, ICG has demonstrated to be useful for the management of heart failure patients and for the diagnostic and therapeutic approach to hypertension, which currently constitute two of the major applications of ICG. In heart failure patients, changes in thoracic fluid content and cardiac output tracked by ICG have shown to be predictors of acute decompensation even weeks before respiratory symptoms appear; also allowing identification of a cardiac vs. respiratory origin of dyspnea when physical examination and laboratory tests are not conclusive. In the particular case of patients with uncontrolled or severe hypertension, ICG makes possible a better characterization of hypertensive phenotype leading to a more specific choice of pharmacological agents to treat the primary hemodynamic alteration (i.e elevated peripheral resistance vs. elevated cardiac output). The present review, provides a review of the biophysical principles of ICG and its precision in measuring stroke volume and present a critical assessment of the literature supporting its clinical application in the management of heart failure and arterial hypertension.

Keywords : impedance cardiography; hemodynamics; heart failure; arterial hypertension.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License