SciELO - Scientific Electronic Library Online

 
vol.22 issue2Malocclusion and orthodontic treatment need in adolescents from Pasto, ColombiaShort implant system. 30-implant report: Part I: osseointegration author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Revista Facultad de Odontología Universidad de Antioquia

Print version ISSN 0121-246X

Abstract

CAPARROSO PEREZ, Carlos Bernardo; MARIN MUNOZ, Diana Virginia  and  ECHAVARRIA VELASQUEZ, Alejandro. Marginal adaptation and internal fit of zirconia-ytrya frameworks fabricated with Procera® and Cerec in-Lab® CAD/CAM systems. Rev Fac Odontol Univ Antioq [online]. 2011, vol.22, n.2, pp.186-197. ISSN 0121-246X.

INTRODUCTION: the purpose of this in vitro study was to determine the marginal adaptation and internal fit in zirconia ytrya frameworks fabricated with Procera® and Cerec In-lab® CAD/CAM systems. METHODS: fifteen prefabricated implant abutments were divided in three equally sized groups; noble metal alloy Pd-Au structures were then fabricated (control group), Procera® and Cerec In-lab YZ cubes® (n = 5). The marginal gap was determined by measuring 8 points around the abutment circumference taking the distance between the margin of the structure and the abutment. In order to determine internal fit, 8 measures were taken from the abutment‚s external surface to the internal surface of the restoration. The measures were done with an optical microscope (50X). The data was the statistically analyzed using 1-way ANOVA, Student‚s paired t test and Dunnett‚test. RESULTS: marginal adaptation mean for the control group was 18.24±4.81µm and Procera® 21.62 µm ±12.15 µm, while the average for Cerec In-lab® was 47.34 µm ±17.72 µm. The internal fit for the control group was 34,60 µm ±16.16 µm and Procera® group was of 118.67 µm ±50.84 µm in average and Cerec In-lab® 65.62 µm ±25.80 µm. CONCLUSION: the metal alloy and zirconia ytrya frameworks fabricated with Procera® and Cerec In-lab® CAD/CAM systems showed clinically acceptable marginal gap values. The internal fit values for metal alloy and Cerec® frameworks are within the ranges reported in the literature. While the mean for the Procera® group was 118.67 µm ±50.84, which is close to the internal fit maximum limit reported in the literature, there was no statistically significant difference when compared with the Cerec-In-lab® system.

Keywords : zirconia-ytria Procera; zirconia ytria Cerec in-Lab; CAD/CAM; marginal adaptation; internal adjustment.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License