SciELO - Scientific Electronic Library Online

 
vol.26 issue1ORTHODONTIC TREATMENT NEEDS ACCORDING TO THE DENTAL AESTHETIC INDEX IN 12-YEAR-OLD ADOLESCENTS, CHILEIN VITRO EVALUATION OF THE EFFECT OF HYDROFLUORIC ACID ONCENTRATION AND APPLICATION TIME ON ADHESION TO LITHIUM DISILICATE author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Revista Facultad de Odontología Universidad de Antioquia

Print version ISSN 0121-246X

Abstract

MEJIA BRAVO, Richard Milton et al. EX VIVO EVALUATION OF THE RETENTION OF PROCERA® ZIRCONIA-YTTRIA SYSTEMS WITH DIFFERENT CEMENTS. Rev Fac Odontol Univ Antioq [online]. 2014, vol.26, n.1, pp.44-61. ISSN 0121-246X.

INTRODUCTION: since the specialized literature does not report reliable protocols for cementing zirconia-yttria restorations, the purpose of this study was to perform an ex vivo assessment of the retention by frictional strength of Procera® zirconia-yttria systems cemented with four materials: Ketac Cem (3M) ESPE), Multilink Automix (Ivoclar Vivadent), Panavia F 2.0 (Kuraray), and RelyX U100 (3M ESPE) on natural teeth. METHODS: We gathered 40 recently extracted third molars, which were disinfected with 0.5% NaOCl and stored in saline solution, embedded in acrylic resin, and cut at a 10° convergence angle per wall with an axial carving of 1.5 mm in depth and 4 mm in height. Impressions were taken with Aquasil Ultra® Dentsply and cast with type IV plaster, obtaining 40 Procera AllZircon (Nobel Biocare) structures. 10 samples per material were cemented and thermocycled x 5,000 cycles of 15 s. They were then tractioned with a universal testing machine and failure types at the different interfaces were analyzed. One-way multiple-range ANOVA statistical analysis was performed. RESULTS: average retention values in Newtons were 440 N for Ketac Cem, 698 N for Multilink Automix, 686 N for Panavia F 2.0, and 551 N for RelyX U100. Dentin adhesion failure occurred in 53.8% of cases, followed by mixed failure, with 12.82%. CONCLUSIONS: resinous cements with acid phosphate monomers reported higher retention values in comparison with conventional acid-base cements. Adherence to dentin and cement handling can affect the final result.

Keywords : dental porcelain; dental cements; denture retention.

        · abstract in Spanish     · text in English | Spanish     · Spanish ( pdf )