SciELO - Scientific Electronic Library Online

 
vol.31 número2Vigilancia de la infección por Rickettsia sp. en capibaras (Hydrochoerus hydrochaeris) un modelo potencial de alerta epidemiológica en zonas endémicasActividad inotrópica inducida por el derivado carbamacepina-alquino en un modelo de corazón aislado y perfundido a flujo constante índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • No hay articulos similaresSimilares en SciELO
  • En proceso de indezaciónSimilares en Google

Compartir


Biomédica

versión impresa ISSN 0120-4157versión On-line ISSN 2590-7379

Resumen

RODINO, Jenniffer et al. Microscopic diagnosis of Pneumocystis jirovecii pneumonia in bronchoalveolar lavage and oropharyngeal wash samples of immunocompromised patients with pneumonia. Biomédica [online]. 2011, vol.31, n.2, pp.222-231. ISSN 0120-4157.

Introduction. The diagnosis of Pneumocystis jirovecii pneumonia is based on observation of the microorganism using several staining techniques in respiratory samples, especially bronchoalveolar lavage and induced sputum. Recently, the fungus also has been detected in oropharyngeal wash samples, but only using molecular tests. Objective. The diagnostic yield of two microscopic stains, toluidine blue O and direct fluorescent antibody, was compared in bronchoalveolar lavage and oropharyngeal wash samples for the detection of P. jirovecii in immunocompromised patients with pneumonia. Materials and methods. Cross-sectional evaluation diagnostic tests were used in 166 immunossupressed patients with suspected P. jirovecii. By protocol, bronchoscopic bronchoalveolar lavage and oropharyngeal wash samples were prepared by cytocentrifugation, and slides were stained with toluidine blue and fluorescent antibody. The proportion of positive results from each stain and concordance between them were determined. Results. Twenty-four cases (14.5%) of P. jirovecii were detected in bronchoalveolar lavage samples. Of them, 21 were positive by both toluidine blue and fluorescent antibody stains, whereas 3 cases were detected by fluorescent antibody alone. None of the 166 oropharyngeal wash samples were positive by either of these techniques. No significant differences were found between proportions from positive results (p=0.63). Concordance (kappa coefficient) between both stains was 0.92 (95% CI: 0.84-1.00). Conclusions. Both techniques were useful to diagnose P. jirovecii in bronchoalveolar lavage samples. However, toluidine blue stain did not detect 12% of fluorescent antibody positive cases. Oropharyngeal wash samples do not provide sufficient material for the microscopic identification of this fungus.

Palabras clave : Pneumonia, Pneumocystis [diagnosis]; fluorescent antibody technique, direct; tolonium chloride; oropharynx; bronchoalveolar lavage; immunocompromised host.

        · resumen en Español     · texto en Español     · Español ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons