SciELO - Scientific Electronic Library Online

 
vol.32 número3Estudio y análisis comparativo de interacciones entre la proteina integrina con fragmentos de la proteína fibrilina-1 y fragmentos mutados de esta utilizando la metodología de docking molecularValidación técnica de una PCR: Reacción en cadena de la polimerasa para la detección de Chlamydia trachomatis índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • No hay articulos similaresSimilares en SciELO
  • En proceso de indezaciónSimilares en Google

Compartir


Revista Salud Uninorte

versión impresa ISSN 0120-5552versión On-line ISSN 2011-7531

Resumen

MARIN OYAGA, Víctor; GUTIERREZ VILLAMIL, Claudia; DUENAS CRIADO, Karen  y  AREVALO LEAL, Sinay. Phase analysis to measure left ventricular dyssynchrony by Gated-SPECT myocardial perfusion imaging showed by two different software. Salud, Barranquilla [online]. 2016, vol.32, n.3, pp.384-397. ISSN 0120-5552.

Abstract Introduction and objectives:Phase analysis by Gated-SPECT myocardial perfusion imaging (G-MPI) is a new tool to measure left ventricular dyssynchrony with important clinical applications in near future (heart failure and resynchronization) and can be measured by two software (ECTb o QGS C-S). The aim is to show its feasibility and verify whether there is difference between the programs. Methodology: Analytical observational and retrospective study in patients with normal G-MPI. The parameters were the phase standard deviation (SD) and the histogram bandwidth (HB) in post-stress and rest tests. Assessment of the difference between groups was performed using tests for independent samples after analyze the distribution of data. The significance level (p) was 0,05 and the software used was SPSS IBM V.21® Results: Total:193 patients (104 men).64 years old ± (24-89).61/193 processed with QGS C-S and 132/193 with ECTb. Post-stress tests: mean of the SD was 6º±3.7º,the median was 5º,interquartile range (IR):3.6º.The mean of HB was 22.7º±10º and the median was 18º IR:11.5º. Post-rest tests: mean of the SD was 5.76º±4.82º and median was 4.5º IR: 3.1º.The overall mean of HB was 21.67º±14.06º and median was 18º IR: 12º. Between the data from both software, significant differences were found in SD in post-stress(p=0.001)and post-rest tests(p=0.019)and no significant differences were found in HB in post-stress(p= 0.31)or post-rest tests(p=0.18). Conclusion: Phase analysis by G-MPI is feasible. However SD showed significant differences between the two groups. Although the values showed could be used as normal values, it is recommended that these have to be obtained and used for each software separately.

Palabras clave : Left ventricular disfunction; myocardial perfusion imaging; radionuclide imaging; phase analysis; cardiac resynchronization therapy.

        · resumen en Español     · texto en Español     · Español ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons