SciELO - Scientific Electronic Library Online

 
vol.26 número1Respuesta de la papa criolla (Solanum tuberosum) cultivar Colombia a la fertilización orgánico mineralFertilización foliar con calcio y su efecto sobre calidad y vida útil en frutos de mora (Rubus glaucus Benth.) índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • No hay articulos similaresSimilares en SciELO
  • En proceso de indezaciónSimilares en Google

Compartir


Revista U.D.C.A Actualidad & Divulgación Científica

versión impresa ISSN 0123-4226

Resumen

CAMARGO-HERNANDEZ, Deisy Bibiana et al. Visible and near infrared spectroscopy for the analysis of nutrients in sugarcane plant tissue for panela production. rev.udcaactual.divulg.cient. [online]. 2023, vol.26, n.1, e2062.  Epub 22-Feb-2023. ISSN 0123-4226.  https://doi.org/10.31910/rudca.v26.n1.2023.2062.

Near Infrared Reflectance Spectroscopy (NIRS) is a fast, multiparametric, environmentally friendly, low-cost, and highly accurate technology for the analysis of components in food, soil, and agriculture. The purpose of this study was to generate NIRS calibration models for the prediction of nutrients in plant tissue of sugarcane to panela production cultivated in the Hoya del Río Suárez region. A total of 416 tissue samples were scanned in Vis-NIR spectral segment. Chemometric analysis was performed with the WinISI V4.10 software applying modified partial least squares regression with cross-validation. Four models with different mathematical treatments were evaluated, and the performance of calibrations was made through external validation analyzing the goodness-of-fit measures as prediction determination coefficient, standard error of the bias-adjusted prediction, and residual predictive deviation. The results showed that the calibration model for N had the highest predictive power. For macronutrients, the calibrations with the best predictive power were for P and K, and micronutrients for B, while Cu presented the lowest predictive power. Adequate models were found for the prediction of N, Ca, and P. In the case of the other nutrients, it is recommended to expand the calibration set.

Palabras clave : Foliar analysis; Plant nutrition; Soil properties; Spectral analysis; Saccharum officinarum.

        · resumen en Español     · texto en Español     · Español ( pdf )