SciELO - Scientific Electronic Library Online

 
vol.67 número1Long term beef production in extensive cow-calf systems in the tropical savannas of eastern ColombiaPredicting soil CO2 emissions and sinks due to soil management factors of Brachiaria decumbens pastures using Tier 2 IPCC Methodology índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Revista de la Facultad de Medicina Veterinaria y de Zootecnia

versão impressa ISSN 0120-2952

Resumo

GUEVARA, B.; RIVAS, M. C.  e  SILVA-ACUNA, R.. Hygienic-sanitary quality of two milking systems in bovine farms located in sector Vuelta Larga, Maturín municipal state, Monagas state (Venezuela). Rev. Med. Vet. Zoot. [online]. 2020, vol.67, n.1, pp.60-71. ISSN 0120-2952.  https://doi.org/10.15446/rfmvz.v67n1.87687.

The objective of the present investigation, was to evaluate the 'Hygienic-Sanitary Quality of two Milking Systems in Bovine Farms' in Vuelta Larga Sector, Maturín City, Monagas State (Venezuela). The trial lasted six weeks, in which the Hygienic Efficiency (% EH) of the facilities, the workers, the milking routine, the cleaning and disinfection measures and the storage and transport of both milking systems, were calculated. Furthermore, the population of Mesophilic Aerobic Bacteria (BAM) was determined ; The data were processed following a distribution in random blocks with factorial arrangement (2x2) whose factor A represented the milking system: manual and mechanical, and the factor B was the application and omission of manual drying of teats for each animal prior to milking. The percentage of Hygienic Efficiency (% EH) of the farms evaluated was not satisfactory, corresponding to 66.66% in the farm 2 and 54.84% in the farm 1. The variable was examined by analysis of variance and its mean values compared by Tukey test at 5% of probability. Factor A achieved a highly significant difference (p ≤0.01), with the manual system obtaining the lowest count with 5.24 Log10 CFU / mL. In factor B significant difference was found (p≤0.05), the drying application decreased the BAM population with 5.25 Log10 CFU / mL. The Hygienic and Sanitary measures implemented in the milking routine directly influence the quality of raw milk.

Palavras-chave : raw milk; microbiology; aerobic mesophilic bacteria; drying.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )