SciELO - Scientific Electronic Library Online

 
vol.22 número2Malocclusion and orthodontic treatment need in adolescents from Pasto, ColombiaShort implant system. 30-implant report: Part I: osseointegration índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Revista Facultad de Odontología Universidad de Antioquia

versão impressa ISSN 0121-246X

Resumo

CAPARROSO PEREZ, Carlos Bernardo; MARIN MUNOZ, Diana Virginia  e  ECHAVARRIA VELASQUEZ, Alejandro. Marginal adaptation and internal fit of zirconia-ytrya frameworks fabricated with Procera® and Cerec in-Lab® CAD/CAM systems. Rev Fac Odontol Univ Antioq [online]. 2011, vol.22, n.2, pp.186-197. ISSN 0121-246X.

INTRODUCTION: the purpose of this in vitro study was to determine the marginal adaptation and internal fit in zirconia ytrya frameworks fabricated with Procera® and Cerec In-lab® CAD/CAM systems. METHODS: fifteen prefabricated implant abutments were divided in three equally sized groups; noble metal alloy Pd-Au structures were then fabricated (control group), Procera® and Cerec In-lab YZ cubes® (n = 5). The marginal gap was determined by measuring 8 points around the abutment circumference taking the distance between the margin of the structure and the abutment. In order to determine internal fit, 8 measures were taken from the abutment‚s external surface to the internal surface of the restoration. The measures were done with an optical microscope (50X). The data was the statistically analyzed using 1-way ANOVA, Student‚s paired t test and Dunnett‚test. RESULTS: marginal adaptation mean for the control group was 18.24±4.81µm and Procera® 21.62 µm ±12.15 µm, while the average for Cerec In-lab® was 47.34 µm ±17.72 µm. The internal fit for the control group was 34,60 µm ±16.16 µm and Procera® group was of 118.67 µm ±50.84 µm in average and Cerec In-lab® 65.62 µm ±25.80 µm. CONCLUSION: the metal alloy and zirconia ytrya frameworks fabricated with Procera® and Cerec In-lab® CAD/CAM systems showed clinically acceptable marginal gap values. The internal fit values for metal alloy and Cerec® frameworks are within the ranges reported in the literature. While the mean for the Procera® group was 118.67 µm ±50.84, which is close to the internal fit maximum limit reported in the literature, there was no statistically significant difference when compared with the Cerec-In-lab® system.

Palavras-chave : zirconia-ytria Procera; zirconia ytria Cerec in-Lab; CAD/CAM; marginal adaptation; internal adjustment.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons