Services on Demand
Journal
Article
Indicators
- Cited by SciELO
- Access statistics
Related links
- Cited by Google
- Similars in SciELO
- Similars in Google
Share
DYNA
Print version ISSN 0012-7353On-line version ISSN 2346-2183
Abstract
OSORIO SARAZ, JAIRO ALEXANDER et al. MODELING AND EXPERIMENTAL VALIDATION TO ESTIMATE THE ENERGY BALANCE FOR A POULTRY HOUSE WITH MISTING COOLING. Dyna rev.fac.nac.minas [online]. 2011, vol.78, n.170, pp.167-174. ISSN 0012-7353.
The aim of this study was to develop and validate a simplified steady state mathematical model to predict temperature distribution in a commercial poultry house equipped with a negative pressure ventilation system and internal misting. The model was validated with data obtained experimentally during the summer. For external temperature conditions of 26, 27, and 29 °C, the best combinations of energy generated by misting (qmisting), ventilation rate (V), global heat loss coefficient for the roof (Ut), and global heat loss coefficient for the wall (Upar) were encountered to maintain the majority of the installation with temperatures within the optimal thermal comfort range for the birds (24 to 29 °C).
Keywords : evaporative cooling; thermal modeling; tunnel ventilation broiler house.