SciELO - Scientific Electronic Library Online

 
vol.71 número3Safety and acceptability of the 52 mg levonorgestrel-releasing intrauterine system in women with abnormal uterine bleeding in an ambulatory care center in Bogotá, Colombia, 2012-2016 índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Revista Colombiana de Obstetricia y Ginecología

versão impressa ISSN 0034-7434versão On-line ISSN 2463-0225

Resumo

RENDON-BECERRA, César Augusto; GOMEZ-BRAVO, Alex; ERAZO-NARVAEZ, Andrés Felipe  e  ORTIZ-MARTINEZ, Roberth Alirio. Diagnostic accuracy of a hysteroscopic score for the detection of endometrial cancer in patients with postmenopausal bleeding and endometrial thickening. Rev Colomb Obstet Ginecol [online]. 2020, vol.71, n.3, pp.237-246.  Epub 30-Set-2020. ISSN 0034-7434.  https://doi.org/10.18597/rcog.3445.

Objective:

To assess the diagnostic accuracy of hysteroscopic scores in endometrial cancer.

Materials and methods:

Diagnostic accuracy study assembled within a cross-sectional study that included patients with postmenopausal bleeding and endometrial thickening greater than 5 mm in whom hysteroscopy was performed and then compared with endometrial biopsy as the diagnostic gold standard, in two high complexity hospitals. Clinical, sociodemographic variables, as well as hysteroscopic scores and the results of endometrial tissue histopathology were measured. Sensitivity and specificity, likelihood ratios and area under the curve with their respective confidence intervals were estimated in the analysis.

Results:

With a 9 % prevalence of endometrial

cancer, the hysteroscopic assessment system was shown to have 75 % sensitivity (95 % CI; 30.1- 95.43), 95,1 % specificity (95 % CI; 83.9-98.7), a positive likelihood ratio of 15.38 (95 %; CI 3.55- 66.56), a negative likelihood ratio of 0.26 and area under the curve of 85 %.

Conclusion:

The standardized hysteroscopic assessment system was found to have an acceptable sensitivity for screening in patients with postmenopausal bleeding and endometrial thickening (≥ 5 mm). Further studies with larger sample sizes are required in order to arrive at a more precise estimation of the operational characteristics of the hysteroscopic assessment system for the detection of endometrial cancer.

Palavras-chave : Uterine hemorrhage; hysteroscopy; endometrial neoplasms; postmenopause..

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )