SciELO - Scientific Electronic Library Online

 
vol.70 issue4Physiological variables of the "metabolic component" of acid-base balance and mortality in intensive care patientsTeaching Health Sciences at the Universidad de Antioquia, Colombia author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Revista de la Facultad de Medicina

Print version ISSN 0120-0011

Abstract

RIASEOS, Lorena Enriquez  and  GARCIA-PERDOMO, Herney Andrés. Risk factors associated with failed weaning from mechanical ventilation in septic patients admitted to an intensive care unit: a case-control study. rev.fac.med. [online]. 2022, vol.70, n.4, e202.  Epub Mar 08, 2023. ISSN 0120-0011.  https://doi.org/10.15446/revfacmed.v70n4.94464.

Introduction:

Several risk factors associated with weaning failure may be observed in septic patients requiring invasive mechanical ventilation.

Objective:

To determine the risk factors associated with weaning failure in septic patients admitted to an intensive care unit (ICU) in Cali, Colombia, between January 2014 and June 2018.

Materials and methods:

Case-control study conducted in 315 patients who required mechanical ventilation for more than 48 hours and were distributed as follows: 105 cases (weaning failure) and 210 controls (successful weaning). Information about sociodemographic and clinical variables was obtained from their medical records. A bivariate analysis was performed to determine the association between each independent variable and weaning failure. A multivariate analysis was also carried out using a logistic regression model in which the variables with a p<0.20 in the bivariate analysis were entered. A significance level of p≤0.05 was considered.

Results:

Requiring mechanical ventilation for more than 7 days (OR: 15.13; 95%CI: 8.25-27.74), having a high APACHE II score (mortality risk >50%) on ICU admission (OR: 3.16; 95%CI: 1.73-5.77), and having diuresis ≤0.5 mL/kg/h (OR: 1.87; 95%CI: 1.0-3.50) were significantly associated with weaning failure.

Conclusions:

Requiring mechanical ventilation for more than 7 days, having diuresis ≤0.5ml/kg/h, as well as a high APACHE ll score on ICU admission were risk factors associated with failed weaning from mechanical ventilation in this study; however, age, blood urea nitrogen, creatinine, and positive fluid balance were not significantly associated with it, despite being described as risk factors in the literature.

Keywords : Sepsis; Respiration, Artificial; Ventilator Weaning (MeSH).