SciELO - Scientific Electronic Library Online

 
vol.32 número2Caracterización fisicoquímica y microbiológica de aguas mieles del beneficio del caféEstudio termoquímico asistido por computadora para la producción de biodiésel índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • No hay articulos similaresSimilares en SciELO
  • En proceso de indezaciónSimilares en Google

Compartir


Revista ION

versión impresa ISSN 0120-100Xversión On-line ISSN 2145-8480

Resumen

GUARIN-GUIO, Paula Andrea; CANO-CALLE, Herminsul de Jesus  y  CASTILLO-LEON, John Jairo. Electrochemical detection of hydrogen peroxide using peroxidase from Guinea grass (Panicum maximum) immobilized on screen-printed quantum dots electrodes. Rev. ion [online]. 2019, vol.32, n.2, pp.67-76.  Epub 22-Dic-2019. ISSN 0120-100X.  https://doi.org/10.18273/revion.v32n2-2019007.

Electrochemical biosensors are analytical tools of fast and reliable response that have acquired interest in the last years due to the possibility of integrating biomolecules and electrodes made of nanometric materials. In this study, an electrochemical biosensor to detect hydrogen peroxide (H2O2) based on Guinea Grass peroxidase (GGP) immobilized on screen-printed quantum dots electrodes (SPQDE) was developed. GGP was partially purified from Guinea grass leaves having a specific activity of 602 U mg-1. Then, GGP was immobilized by physical adsorption on the surface on SPQDE and the electrochemical behavior was carried out through cyclic voltammetry and chronoamperometry techniques. GGP revealed a well-defined pair of redox signals at 17 mV/-141 mV corresponding to the redox process of the heme group (Fe2+/Fe3+) of peroxidases. The bioelectrocatalytic reduction of H2O2 has a redox potential of -645 mV vs Ag. This process was controlled by the diffusion of the species on the electrode surface using a scan rate range of 50-500 mV s. Chronoamperometry studies allow us the construction of calibration curves of reduction current vs H2O2 concentration for the determination of analytical parameters such as sensitivity, linear range and minimum detection level. The development of this amperometric biosensor becomes a preliminary step for the construction of a portable and rapid response device for the analysis of H2O2 in samples of environmental and biomedical interest.

Palabras clave : Biosensor; Peroxidase; Guinea Grass; Hydrogen Peroxide; Quantum Dots..

        · resumen en Español | Portugués     · texto en Español     · Español ( pdf )