SciELO - Scientific Electronic Library Online

 
vol.41 número4Anesthetic complications in patients with inborn errors of metabolism undergoing non-cardiac surgeryVariables associated with the risk of suicide in patients with chronic pain seen in a hospital outpatient clinic in Bogotá índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Colombian Journal of Anestesiology

versão impressa ISSN 0120-3347

Resumo

CALVACHE, José Andrés; SANDOVAL, Maria Ximena  e  ANDRES VARGAS, William. Pressure applied by the healthcare staff on a cricoid cartilage simulator during Sellick’s maneuver in rapid sequence intubation. Rev. colomb. anestesiol. [online]. 2013, vol.41, n.4, pp.261-266. ISSN 0120-3347.  https://doi.org/10.1016/j.rca.2013.09.004.

Bacfeground:Sellick's maneuver or cricoid pressure is a strategy used to prevent bronchoas-piration during the rapid intubation sequence. Several studies have described that the forcerequired for an adequate maneuver is of 2.5-3.5 kg. The purpose of this paper was to determine the force applied (in kilograms) on a cricoid cartilage simulator by the health care professionals. Methodology:Observational cross-section trial. The participants were the healthcare professionals at the San José University Hospital in Popayán and participants at the National Congress of Anesthesiology - S.C.A.R.E. 2011, who were conveniently selected. Every participant made three attempts to apply the maneuver on the simulator. Results: Data from 156 participants were collected. The mean global pressures applied in the first, second and third attempts were 2.70, 2.71 and 2.73 kg, respectively. Following a multivariate adjustment, males exhibited a higher force at the first attempt to do the maneuver. No association was found to other variables, such as labor experience or the training level. Conclusions:The pressure applied by the participants in the trial during the first attempt was 2.7 kg. Most of the subjects in the trial did Sellick's maneuver applying an inadequate pressure in their first attempt. Only males exerted an overpressure in their first attempt todo the maneuver.

Palavras-chave : Intubation; Cricoid Cartilage; Simulation; Trachea; Airway Management.

        · resumo em Espanhol     · texto em Espanhol | Inglês     · Inglês ( pdf ) | Espanhol ( pdf )