vol.45 suppl.2Effect of the Extended Inverted Classroom on clinical simulation for the resuscitation of trauma patients: Pilot study of student perceptions of learningPortrayal of the performance of the post-anesthesia care unit, based on the perception of the professional nursing staffs author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Colombian Journal of Anestesiology

Print version ISSN 0120-3347

Abstract

LUNA, Carlos Andrés; TULCAN-TORO, Rubén; ROMERO, Felipe  and  LUNA, Mario Fernando. Measurement of residual volume in spinal needles after spinal anesthesia. Rev. colomb. anestesiol. [online]. 2017, vol.45, suppl.2, pp.12-15. ISSN 0120-3347.

Introduction:

Spinal anesthesia involves the administration of a dose of local anesthesia into the intrathecal space of the lumbar spine, using spinal needles with varying characteristics and design. When completing the administration of spinal anesthesia, you may check the volume of fluid remaining inside the spinal needle.

Objective:

To measure and compare the volume of residual fluid following the administration of spinal anesthesia using three different brands of 27 gauge spinal needles.

Methods:

This is an observational analytical cross-section trial for which tree types of 27 gauge commercial needles were selected: BD Whitacre pencil point, Spinocan Quincke sharp point, and Disposable spinal needle. Following the administration of spinal anesthesia, the same operator, without detaching the syringe from the needle, deposited the residual vol ume into a collection tube so that a second operator quantifies the volume using a precision micropipette.

Results:

The residual volume obtained fromthe27Gspinalneedlesshowed astatistically significant difference in favor of the BD Whitacre needles (P < 0.01), compared against Spinocan Quincke and Disposable spinal needle.

Conclusions:

The BD Whitacre pencil point proved to lodge less residual volume following spinal anesthesia. No clinical implications can be made from this finding and new studies are required to ratify these results.

Keywords : Anesthesia conduction Needles.