vol.47 número2Evaluation of a closed-loop intravenous total anesthesia delivery system with BIS monitoring compared to an open-loop target-controlled infusion (TCI) system: randomized controlled clinical trialManagement and perioperative outcomes of traumatic brain injury: retrospective study índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Colombian Journal of Anestesiology

versão impressa ISSN 0120-3347

Resumo

PRADA-MANCILLA, William Andrés et al. Comparison of effectiveness between a conventional catheter and a manual commercial catheter: randomized trial of simulation of intraosseous access in a biological model. Rev. colomb. anestesiol. [online]. 2019, vol.47, n.2, pp.92-99.  Epub 01-Maio-2019. ISSN 0120-3347.  https://doi.org/10.1097/cj9.0000000000000101.

Introduction:

In the emergency services an action of paramount importance in critically ill patients is to obtain an early vascular access. When vascular access is not established, an intraosseous route should be obtained; otherwise, the mortality of these critically ill patients is almost 100%. In Colombia, the intraosseous access is not used because of the high costs of the devices and the lack of training of the healthcare staff to conduct the procedure.

Objective:

To determine the efficacy of a low-cost device to establish intraosseous access.

Materials and methods:

Quantitative approach, experimental design in a simulated environment with chicken tarsus and metatarsus. An analysis was conducted using frequency tables and central tendency measurements. Likewise, further analyses were done using Fisher's exact test, Chi2, and Mann-Whitney test.

Results:

A total of 99% of the procedures were successful with both catheters. The average time for intraosseous access was 6.6 seconds with Insyte 14 catheter and 4.7 seconds with Din 1515x Illinois Desch device (P = 0.001). There were no significant differences in the number of attempts to secure a successful intra-osseous access using any of the 2 devices (P = 0.56).

Conclusion:

There was no significant difference between the Ci 14 and the Si 14 catheter to establish a successful intraosseous access in the chicken tarsus and metatarsus in a simulated environment.

Palavras-chave : Infusions; Intraosseous; Clinical Trials as Topic; Vascular Access Devices; Critical Care; Efficacy.

        · resumo em Espanhol     · texto em Inglês | Espanhol     · Inglês ( pdf ) | Espanhol ( pdf )