SciELO - Scientific Electronic Library Online

 
vol.51 número2Premedication with midazolam in low-risk surgery in children does not reduce postoperative delirium. Prospective cohort study índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Colombian Journal of Anestesiology

versão impressa ISSN 0120-3347versão On-line ISSN 2256-2087

Resumo

LAVERDE-SABOGAL, Carlos Eduardo et al. Risk factors of self-extubation in intensive care. Retrospective cohort study. Rev. colomb. anestesiol. [online]. 2023, vol.51, n.2, 20.  Epub 24-Maio-2023. ISSN 0120-3347.  https://doi.org/10.5554/22562087.e1050.

Introduction

Acute respiratory failure remains one of the three leading causes of admission to the intensive care unit (ICU). Self-extubation is an adverse outcome requiring reintubation in 50% of cases.

Objective

To assess for determinants (risk factors) of self-extubation and mortality in the ICU by using a generalized estimation equation model (GEE).

Methods

The data was collected from a retrospective cohort study from 2017-2020 including all patients admitted to the ICU with mechanical ventilation. Univariate and bivariate analyses were performed. Then, a GEE model was conducted to predict the risk of self-extubation and mortality.

Results

A total of 857 subjects were included, with a mean age of 60.5 +/- 17 years-old. Most of the subjects were males (55.2%). An 8.99-fold risk (95%CI 3.83-21.1, p<0.0i) of self-extubation was identified in patients with agitation. Exposure to infusion of neuromuscular blockade was also found to increase the risk of self-extubation 3.37 times (95%CI 1.31-8.68, p=0.01). No associations were identified between immobilization and self-extubation (OR 1.38 95%CI 0.76-2.51, p=0.29). Finally, light sedation according to the Richmond Sedation Scale (RASS) between 0 to -2 rather than moderate (RASS-3) reduces the risk of mortality (OR 0.57, 95%CI 0.38-0.83, p<0.01).

Conclusions

The main factors resulting in self-extubation were: agitation, delirium, and infusion of neuromuscular blocking agents. An association was found between light sedation and a lower risk of mortality. No association was found between the use of physical restraint and the desired outcome.

Palavras-chave : Airway extubation; Artificial respiration; Critical care; Self-Extubation; Anesthesiology.

        · resumo em Espanhol     · texto em Inglês | Espanhol     · Inglês ( pdf ) | Espanhol ( pdf )