SciELO - Scientific Electronic Library Online

 
vol.52 issue3Clinicai characteristics and mortality in mechanically ventilated COVID-19 patients: prospective cohort studyCurrent situation of pediatric anesthesiology training in Colombia author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Colombian Journal of Anestesiology

Print version ISSN 0120-3347On-line version ISSN 2256-2087

Abstract

ESTRADA-OROZCO, Kelly et al. Reduction of catheter-associated bloodstream infections: Effectiveness of the continuous quality improvement method at a university hospital in Colombia. Rev. colomb. anestesiol. [online]. 2024, vol.52, n.3, 4.  Epub May 30, 2024. ISSN 0120-3347.  https://doi.org/10.5554/22562087.e1106.

Introduction:

Central Line-Associated Bloodstream Infections (CLABSI) are preventable and potential fatal events, frequent in critical patient care. By mid-2018 an increase was noted in the incidence rate of CLABSI at a high complexity institution in Colombia, demanding immediate interventions to lower those numbers.

Objective:

To assess the effectiveness of the continuous quality improvement methodology (CQI) to lower the incidence rate of CLABSI at a university hospital in Bogotá, Colombia.

Methods:

Longitudinal, prospective study implementing a multifaceted intervention in accordance with the CQI methodology. The project was developed at a high complexity university hospital in Bogotá, Colombia, between July 2018 and December 2019. A root cause analysis was consecutively conducted prioritizing contributing factors, gathering ideas for improvement, building a strategy and prioritizing the implementation plan.

Results:

The CQI methodology enabled the identification of areas susceptible of catheter insertion and management errors at the institution; additionally, it allowed for the prioritization of the areas requiring intervention through consecutive test cycles for improvement ideas. The reduction and sustainability of insertion-related CLABSI was accomplished three months after the start of the interventions, achieving a zero value. The implementation of improvement ideas aimed at reducing the events associated with catheter maintenance was also able to reduce the incidence to zero, until the end of the period of observation of the study.

Conclusions:

It is feasible to implement CQI in settings similar to the one herein described, in order to efficiently reduce CLABSIs.

Keywords : PDSA; Infection control; Patient safety; Quality improvement; Catheter-related infection.