SciELO - Scientific Electronic Library Online

 
vol.27 número4Nutritional status of children with malaria in northwest ColombiaClinical profiles of patients with uncomplicated Plasmodum falciparum malaria in northwestern Colombia índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Biomédica

versão impressa ISSN 0120-4157versão On-line ISSN 2590-7379

Resumo

MENDOZA, Nohora Marcela et al. Evaluation of two rapid diagnostic tests, NOW® ICT Malaria Pf/Pv and OptiMAL®, for diagnosis of malaria. Biomédica [online]. 2007, vol.27, n.4, pp.571-580. ISSN 0120-4157.

Introduction. To increase the accessibility of malaria diagnosis, the Instituto Nacional de Salud de Colombia undertook a field trial to evaluate the sensitivity and specificity of two rapid diagnostic tests. Objective. The sensitivity, specificity and concordance was compared for two rapid diagnostic tests for malaria, NOW® ICT Malaria Pf/Pv and OptiMAL®, Materials and methods. A descriptive and concordance study was performed with 214 patients in the southwestern coastal city of Tumaco, Colombia, each of whom presented at least one of the symptoms of the classical malaria triad. Two strategies were applied for patient recruitment-one by passive search and a second through local health brigades. Results. NOW® ICT showed a general sensitivity of 98.4% (95%CI: 90.3-99.9), and a general specificity of 98.0% (95%CI: 93.9-99.5). For Plasmodium falciparum, the sensitivity was 98.2% (95%CI: 89.4-99.9) and the specificity 98.1% (95%CI: 94.1-99.5). The sensitivity was lower (80.0%) when parasitemia ranged from 200 to 4,000 parasites/ µl. The sensitivity and specificity of the NOW® ICT for P. vivax malaria were 100%. The sensitivity for this test was not affected for the established ranges of parasitemia for P. vivax. The overall figures for OptiMAL® were 95.2% (95%CI: 85.8-98.8) sensitivity and 99.3% (95%CI: 95.8-100.0) specificity. For P. falciparum malaria OptiMAL® showed 94.7% (95%CI: 84.5-98.6) sensitivity and 99.4% (95%CI: 96.0-100.0) specificity. The sensitivity was lower (60.0%) when samples with 200-4,000 parasites/µl were tested. For P. vivax, OptiMAL® presented a 66.7% (95%CI: 24.1-94.0) sensitivity, which diminished to 50% with a parasitemia between 300-2.500 parasites/ µL. Conclusions. Good results for sensitivity and specificity were obtained for malaria diagnosis using NOW® ICT and OptiMAL®, with NOW®ICT showing higher sensitivity and specificity values than OptiMAL®.

Palavras-chave : malaria [diagnosis]; sensitivity and specificity; parasitemia; Plasmodium vivax; Plasmodium falciparum; Colombia.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons