SciELO - Scientific Electronic Library Online

 
vol.32 issue3Study and comparative analysis of interactions protein between the integrina with fragments fibrillin-1 and mutated fragments of this by using molecular dockingTechnical validation of a polymerase chain reaction for Chlamydia trachomatis detection author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Revista Salud Uninorte

Print version ISSN 0120-5552On-line version ISSN 2011-7531

Abstract

MARIN OYAGA, Víctor; GUTIERREZ VILLAMIL, Claudia; DUENAS CRIADO, Karen  and  AREVALO LEAL, Sinay. Phase analysis to measure left ventricular dyssynchrony by Gated-SPECT myocardial perfusion imaging showed by two different software. Salud, Barranquilla [online]. 2016, vol.32, n.3, pp.384-397. ISSN 0120-5552.

Abstract Introduction and objectives:Phase analysis by Gated-SPECT myocardial perfusion imaging (G-MPI) is a new tool to measure left ventricular dyssynchrony with important clinical applications in near future (heart failure and resynchronization) and can be measured by two software (ECTb o QGS C-S). The aim is to show its feasibility and verify whether there is difference between the programs. Methodology: Analytical observational and retrospective study in patients with normal G-MPI. The parameters were the phase standard deviation (SD) and the histogram bandwidth (HB) in post-stress and rest tests. Assessment of the difference between groups was performed using tests for independent samples after analyze the distribution of data. The significance level (p) was 0,05 and the software used was SPSS IBM V.21® Results: Total:193 patients (104 men).64 years old ± (24-89).61/193 processed with QGS C-S and 132/193 with ECTb. Post-stress tests: mean of the SD was 6º±3.7º,the median was 5º,interquartile range (IR):3.6º.The mean of HB was 22.7º±10º and the median was 18º IR:11.5º. Post-rest tests: mean of the SD was 5.76º±4.82º and median was 4.5º IR: 3.1º.The overall mean of HB was 21.67º±14.06º and median was 18º IR: 12º. Between the data from both software, significant differences were found in SD in post-stress(p=0.001)and post-rest tests(p=0.019)and no significant differences were found in HB in post-stress(p= 0.31)or post-rest tests(p=0.18). Conclusion: Phase analysis by G-MPI is feasible. However SD showed significant differences between the two groups. Although the values showed could be used as normal values, it is recommended that these have to be obtained and used for each software separately.

Keywords : Left ventricular disfunction; myocardial perfusion imaging; radionuclide imaging; phase analysis; cardiac resynchronization therapy.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License