SciELO - Scientific Electronic Library Online

 
vol.19 número2Implante de resincronizador cardiaco por vía femoral: Una alternativa para accesos subclavios difíciles índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • No hay articulos similaresSimilares en SciELO
  • En proceso de indezaciónSimilares en Google

Compartir


Revista Colombiana de Cardiología

versión impresa ISSN 0120-5633

Resumen

BALPARDA, Jon Kepa et al. Non-invasive hemodynamic evaluation with impedance cardiography: applications in heart failure and hypertension. Rev. Colomb. Cardiol. [online]. 2012, vol.19, n.2, pp.82-90. ISSN 0120-5633.

Impedance cardiography (ICG) represents a non-invasive method for hemodynamic assessment in a beat-to-beat basis. Since its introduction more than forty years ago, a renewed interest in the use of this technique during the last decade has been noticed, mainly as a result of a series of clinical studies showing its precision in the estimation of stroke volume either against invasive gold standard (i.e. thermodilution) or against non-invasive reference methods (i.e. echocardiography). On the other hand, ICG has demonstrated to be useful for the management of heart failure patients and for the diagnostic and therapeutic approach to hypertension, which currently constitute two of the major applications of ICG. In heart failure patients, changes in thoracic fluid content and cardiac output tracked by ICG have shown to be predictors of acute decompensation even weeks before respiratory symptoms appear; also allowing identification of a cardiac vs. respiratory origin of dyspnea when physical examination and laboratory tests are not conclusive. In the particular case of patients with uncontrolled or severe hypertension, ICG makes possible a better characterization of hypertensive phenotype leading to a more specific choice of pharmacological agents to treat the primary hemodynamic alteration (i.e elevated peripheral resistance vs. elevated cardiac output). The present review, provides a review of the biophysical principles of ICG and its precision in measuring stroke volume and present a critical assessment of the literature supporting its clinical application in the management of heart failure and arterial hypertension.

Palabras clave : impedance cardiography; hemodynamics; heart failure; arterial hypertension.

        · resumen en Español     · texto en Español     · Español ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons