SciELO - Scientific Electronic Library Online

 
vol.23 número2Frequency and demographic characteristics of patients diagnosed thrombosis coronary stent implantation in a university hospital from January 2011 to December 2012Chemotherapy-induced cardiotoxicity from molecular bases to clinical perspective índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Revista Colombiana de Cardiología

versão impressa ISSN 0120-5633

Resumo

DUQUE, Mauricio et al. Use of closed loop sensor pacing system in patients with vasovagal syncope refractory to medical treatment. Rev. Colomb. Cardiol. [online]. 2016, vol.23, n.2, pp.96-103. ISSN 0120-5633.  https://doi.org/10.1016/j.rccar.2015.07.012.

Introduction: Previous studies have not found a clear benefit related to the use of pacemakers in cardioinhibitory syncopes; however, most of them were conducted with pacing systems using stimulation algorithms based in the abrupt drop of the heart rate. Objetive: To assess the impact of cardiac stimulation using a closed loop sensor pacemaker in the number of syncopes and its impact in the quality of life of patients with a vasovagal syncope refractory to medical treatment. Methods: Prospective registration of patients diagnosed with vasovagal syncope refractory to medical treatment, who were implanted a bicameral closed loop sensor pacemaker between August 2008 and August 2013. Frequency of syncopal events and quality of life (using the SFSQ) were assessed before and after implanting the device. Results: 51 patients were included (27 women, 53%), with an average age of 52.98 ± 16.88 and a follow-up of 20.19 ± 14.64 months. 30 cases (58.8%) of cardioinhibitory syncope were registered, 20 (39.21%) were mixed and 1 (1.9%) was vasodepressor. The number of syncopes after the implantation of the closed loop sensor device was significantly reduced. Before the pacemaker was implanted, the total of registered syncopes was 198, a value that was reduced to 10 after the implantation (a 94.9% drop). Patients experienced 3.88 ± 3.52 before the implantation, and they decreased to 0.19 ± 0.63 episodes postimplant (p <0.001). Quality of life improved after the implantation: patient average SFSQ score before the implantation was of 70.19 ± 24.5 vs. 15.88 ± 13.73 postimplant (p = 0.000). Conclusion: Implanting a closed loop sensor pacemaker in patients with vasovagal syncope refractory to medical treatment revealed a significant decrease in the number of syncopes and an improvement in the quality of life.

Palavras-chave : Marcapasos; Síncope vasovagal; Estimulación ventricular.