SciELO - Scientific Electronic Library Online

 
 número80Blast densification: A proposed methodology to quantify the amount of densification required to prevent liquefaction and flow in sandy soilsA comparison of linear and nonlinear model performance of shia_landslide: a forecasting model for rainfall-induced landslides índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Revista Facultad de Ingeniería Universidad de Antioquia

versão impressa ISSN 0120-6230

Resumo

PIRE-SIERRA, María Carolina et al. Nitrogen and cod removal from tannery wastewater using biological and physicochemical treatments. Rev.fac.ing.univ. Antioquia [online]. 2016, n.80, pp.63-73. ISSN 0120-6230.  https://doi.org/10.17533/udea.redin.n80a08.

An integrated wastewater treatment was evaluated for nitrogen and COD removal from a tannery effluent. The system was conformed by the combination of a biological treatment using a sequencing batch reactor (SBR) followed by a physicochemical treatment based in a coagulation-flocculation process. The contaminants in the tannery wastewater had average concentrations of 1546 mg COD·L−1, 200 mg TKN·L−1 and 121 mg N-NH4 +·L−1. The duration of a complete SBR operation cycle was 12 h. Dissolved oxygen (DO), pH and oxidation-reduction potential (ORP) were used to monitor biological nutrient removal process in the reactor. In addition, densities of nitrifying and denitrifying microorganisms in the mixed liquor were evaluated during the biological treatment. During physicochemical treatment, the concentrations of FeCl3.6H2O and sour brine (agroindustrial waste used as adjuvant) were 2.7 and 100 g·L-1, respectively (doses were 60 and 5 mL·L-1, respectively). Results show the integrated treatment system was effective to produce an effluent suitable for discharge into water bodies, according to the Venezuelan environmental regulations. Average effluent concentrations were 303 mg COD L−1, 35.1 mg TN·L−1 and 0.5 mg N-NH4 +·L-1, giving COD, TN and N-NH4 + removals of 80%, 82% and 99.6%, respectively. Profiles of ORP, DO and pH were efficient ways to monitor the evolution of biological nutrient removal and real-time control can be implemented in order to optimize the SBR operation. Finally, density of nitrifying bacteria was greater than density of denitrifying bacteria during biological treatment.

Palavras-chave : Tannery wastewater; biological treatment; physicochemical treatment; nutrient removal; online monitoring; bacterial density.

        · resumo em Espanhol     · texto em Inglês     · Inglês ( pdf )