SciELO - Scientific Electronic Library Online

 
vol.21 número1Radiographic and clinical assessment of García’s distractor appliance® for the treatment of anterior open bite in patients treated at the College of Dentistry, University of Antioquia, Medellín índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Revista Facultad de Odontología Universidad de Antioquia

versão impressa ISSN 0121-246X

Resumo

ARANGO, Paola Andrea; PORRAS, Andrés Felipe  e  ARISMENDI E, Jorge Alberto. Immediate load in single-tooth restorations: a clinical prospective study. Rev Fac Odontol Univ Antioq [online]. 2009, vol.21, n.1, pp.6-15. ISSN 0121-246X.

INTRODUCTION: immediate loading of implants has become a viable treatment alternative that offers multiple benefits for patients such as providing immediate function and esthetics, reduction of surgical trauma and less treatment time. A controlled prospective clinical trial was conducted to evaluate the success of immediately loaded implants for single-tooth restoration following consensus protocols in recent literature. METHODS: twenty-one 3.75 x 13mm RBM-treated surface internal connection implants (Renova®, Lifecore Biomedical Inc., Chaska Mn. ) were placed in 17 systemically healthy patients (6 males, 11 females), ages between 18 and 74 years who required single-tooth replacement in the anterior and premolar regions of both jaws. RESULTS: the 18-month cumulative success rate for this study was 95.2%. According to the statistical analysis in this study, immediate loading of implants for single-tooth restoration compares favorably to the two-stage protocol and a direct correlation between the distance from bone to contact point and papilla filling was found. CONCLUSIONS: results from the present study indicate that the single-tooth restoration in the anterior area with immediately loaded surface-treated threaded titanium implants and no occlusal function is a viable treatment alternative with a success rate greater than 95%, comparable to the conventional loading protocol.

Palavras-chave : titanium implants; immediate loading; primary stability; implant insertion torque.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons