SciELO - Scientific Electronic Library Online

 
vol.21 número2Fixed partial prosthesis: biomechanical analysis of stress distribution among three retention alternativesDental fluorosis in children of private schools: Medellín, Colombia, 2007 índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Revista Facultad de Odontología Universidad de Antioquia

versão impressa ISSN 0121-246X

Resumo

ARISMENDI, Jorge Alberto et al. Machined versus rough surface implants, a clinical study: 36-month follow-up. Rev Fac Odontol Univ Antioq [online]. 2010, vol.21, n.2, pp.159-169. ISSN 0121-246X.

INTRODUCTION: the implant surface affects the clinical response in terms of osseointegration and should be evaluated in the long term. In the last years, literature has strongly recommended the use of modified surface implants, in order to improve osseointegration. The primary stability is essential to obtain osseointegration and it depends on the micro and macro characteristics of the implant and bone structure. The usage of active surfaces is an advantage, but it does not modify the bone density. The aim of this study is to undertake a clinical and radiographic evaluation between two different groups of implants, machined versus modified surfaces. METHODS: a 24 to 36 months clinical and radiographic follow-up was done to two groups of Lifecore® implants, one group with 30 machined implants (Super CAT®), and the other one with 30 modified surface (RBM®) external hex connection and screw type implants. Measurements were taken to determine the bone crest behavior using the implant platform as reference at 24-36 months of function and were compared with the 12 months measurements. RESULTS: in machined implants at 24-36 months, the average marginal bone loss was 1.5 mm. In modified surface implants at 24 months, the average marginal bone loss was 1.4 mm, and at 36 months, the loss was 1.5 mm. CONCLUSIONS: there are no statistical significant differences between the two groups of machined and modified implant surface, for single tooth restoration, as it relates to clinical and radiographic follow up.

Palavras-chave : osseointegration; implants; titanium.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons