SciELO - Scientific Electronic Library Online

 
vol.24 número2DEGREE OF ROOT CANAL TRANSPORTATION OF THREE ROTARY INSTRUMENTATION SYSTEMS: A CONE-BEAM COMPUTED TOMOGRAPHY STUDYORAL HEALT H STATUS OF PATIENTS OVER 18 YEARS. PREVENTIVE CLINIC PRACTICUM I, UNNE SCHOOL OF DENTISTRY , ARGENTINA, 2010 índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Revista Facultad de Odontología Universidad de Antioquia

versão impressa ISSN 0121-246X

Resumo

CABRALES, Manuel; ARISMENDI, Jorge Alberto; ZAPATA, Alejandro  e  GOMEZ, Juan Carlos. SHORT IMPLANT SYSTEMS. PART II: SOFT TISSUE STABILITY. Rev Fac Odontol Univ Antioq [online]. 2013, vol.24, n.2, pp.202-213. ISSN 0121-246X.

INTRODUCTION: the purpose of this study was to evaluate position change of the soft tissues surrounding double-stage surgery short implants six months after restoration with individual crowns extra-orally cemented. METHODS:clinical and radiographic measurements were made on metal-ceramic single restorations in 22 patients, supported by Bicon® short implants (30 implants in total), at the time of installing the restoration and 6 months after load. The clinical distances measured were: gingival margin-incisal border (GM—IB), papillary vertex-mesial contact point (PV-MCP), papillary vertex-distal contact point (PV—DCP), papillary vertex-incisomesial angle (PV-IMA), papillary vertex-incisodistal angle (PV-IDA), gingival margin-mucogingival line (GM-MGL) , and the radiographic distances measured were : bone ridge-mesial contact point (BR-MCP), and bone ridge—distal contact point (BR-DCP). RESULTS: no statistically significant differences were found in the aforementioned variables, except for the PV—DCP distance which measured 2.55 mm at the time of installation and 1.49 mm six months afterwards, considered as a statistically significant difference (p = 0.003). CONCLUSION: the results show a stable behavior of soft tissue and bone support around the implants, with a favorable change in the position of the papillae and a slight apically modification in the position of gingival margin.

Palavras-chave : estabilidad de tejidos blandos; implante corto; restauración de diente único; cementación extraoral.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )