SciELO - Scientific Electronic Library Online

 
vol.26 número1NECESIDAD DE TRATAMIENTO ORTODÓNCICO SEGÚN EL ÍNDICE DE ESTÉTICA DENTAL EN ADOLESCENTES DE 12 AÑOS, CHILEEVALUACIÓN IN VITRO DEL EFECTO DE LA CONCENTRACIÓN Y EL TIEMPO DE APLICACIÓN DEL ÁCIDO FLUORHÍDRICO SOBRE LA ADHESIÓN AL DISILICATO DE LITIO índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • No hay articulos similaresSimilares en SciELO
  • En proceso de indezaciónSimilares en Google

Compartir


Revista Facultad de Odontología Universidad de Antioquia

versión impresa ISSN 0121-246X

Resumen

MEJIA BRAVO, Richard Milton et al. EX VIVO EVALUATION OF THE RETENTION OF PROCERA® ZIRCONIA-YTTRIA SYSTEMS WITH DIFFERENT CEMENTS. Rev Fac Odontol Univ Antioq [online]. 2014, vol.26, n.1, pp.44-61. ISSN 0121-246X.

INTRODUCTION: since the specialized literature does not report reliable protocols for cementing zirconia-yttria restorations, the purpose of this study was to perform an ex vivo assessment of the retention by frictional strength of Procera® zirconia-yttria systems cemented with four materials: Ketac Cem (3M) ESPE), Multilink Automix (Ivoclar Vivadent), Panavia F 2.0 (Kuraray), and RelyX U100 (3M ESPE) on natural teeth. METHODS: We gathered 40 recently extracted third molars, which were disinfected with 0.5% NaOCl and stored in saline solution, embedded in acrylic resin, and cut at a 10° convergence angle per wall with an axial carving of 1.5 mm in depth and 4 mm in height. Impressions were taken with Aquasil Ultra® Dentsply and cast with type IV plaster, obtaining 40 Procera AllZircon (Nobel Biocare) structures. 10 samples per material were cemented and thermocycled x 5,000 cycles of 15 s. They were then tractioned with a universal testing machine and failure types at the different interfaces were analyzed. One-way multiple-range ANOVA statistical analysis was performed. RESULTS: average retention values in Newtons were 440 N for Ketac Cem, 698 N for Multilink Automix, 686 N for Panavia F 2.0, and 551 N for RelyX U100. Dentin adhesion failure occurred in 53.8% of cases, followed by mixed failure, with 12.82%. CONCLUSIONS: resinous cements with acid phosphate monomers reported higher retention values in comparison with conventional acid-base cements. Adherence to dentin and cement handling can affect the final result.

Palabras clave : dental porcelain; dental cements; denture retention.

        · resumen en Español     · texto en Español | Inglés     · Español ( pdf )