PIEDRA-SARMIENTO, Liliana Andrea; ARIZA-SALAS, María Claudia; GUZMAN-BAEZ, Humberto José e ZARATE-CADENA, Fernando. COMPARISON OF DEBONDING RESISTANCE AND FAILURE TYPE OF THREE ORTHODONTIC BAND CEMENTS. Rev Fac Odontol Univ Antioq [online]. 2016, vol.28, n.1, pp.95-111. ISSN 0121-246X. https://doi.org/10.17533/udea.rfo.v28n1a5.
Introduction:
the objective of this study was to compare the debonding resistance and failure type observed in three materials used for band cementation by means of the universal testing machine and a stereomicroscope.
Methods:
72 third lower molars were collected from patients who needed extractions; metal bands were cemented on them with a pre-soldered tube and internal etching (Bracket USED, OrthoUSA, USA). The samples were randomly sorted out in three groups, forming a control group (zinc phosphate) and two pilot groups (resin-modified glass ionomer and polyacid-modified composite resin). All samples were subjected to a process of 2000 thermal cycles, and later to a debonding resistance test in the universal testing machine (Instron 3367 class 0.5, with 0-30 Kn load cell, USA) at a speed of 2 mm/min. The data were calculated in megapascals, taking into account the surface area of bands (mm2). Finally, to determine failure type, a visual inspection was conducted using a stereomicroscope (Stemi 2000C, Carl Zeiss, Göttingen, Germany AXIOCAM Carl Zeiss Microimaging, Göttingen, Germany).
Results:
no statistically significant differences were found among the three study groups in terms of debonding resistance (p value = 0.119). The most predominant failure type in the three cements occurred at the cemento-enamel interphase, with 61.1%, showing a statistically significant difference.
Conclusion:
zinc phosphate, resin-modified glass ionomer and polyacid-modified composite resin showed similar debonding resistance values and the most predominant failure type in the three band cementing materials occurred at the cemento-enamel interface; however, the resin-modified glass ionomer showed a lower percentage.