SciELO - Scientific Electronic Library Online

 
vol.21 issue3THE ADSORPTION THERMODYNAMICS OF SUGARCANE (Saccharum officinarum L.) POWDER OBTAINED BY SPRAY DRYING TECHNOLOGYFUNGAL GROWTH INHIBITION OF Aspergillus ochraceus WITH "PANELA"FERMENTED WITH WATER KEFIR GRAINS author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Vitae

Print version ISSN 0121-4004

Abstract

VELA PERDOMO, Karen Lorena; TAFUR GARZON, Mc allister; VELA FLOREZ, Martha Patricia  and  SUAREZ ALFONSO, Martha Cecilia. PRELIMINARY EVALUATION OF THE BIOASSAY FOR THE DETECTION OF ANTIMICROBIAL IN BOVINE MUSCLE. Vitae [online]. 2014, vol.21, n.3, pp.178-190. ISSN 0121-4004.

Background: In Colombia, the vigilance of the Maximum Residue Limits MRLs of veterinary antimicrobials in cattle meat is limited, because the analytical capacity is insufficient to monitor a large number of samples and a wide range of antibiotics. The bioassay is a microbiological method developed by the health public agency (FSIS) of the United States Department of Agriculture (USDA) for the detection, identification and semiquantification of antimicrobial residues in cattle muscle. Objective: It was evaluated preliminary the bioassay for use as a test for the qualitative detection for monitoring and surveillance of four antimicrobials in cattle muscle, as contribution to the inocuity management system within the agreement framework about the application of Sanitary and Phytosanitary Measures; using some guidelines of the European Decision 2002/657/EC. Methods: The experimental protocol used fortified tissues with varying concentrations of penicillin G potassium, oxytetracycline, erythromycin and streptomycin, as representatives of the four important families of veterinary antibiotics used in Colombia. To establish the performance criteria of the bioassay were prepared six replicates of each of the levels or concentrations tested for antimicrobial, including a level without fortification and five levels of lower antibiotic concentrations, equal and above MRL Maximum Residue Limit for each one of the tested antimicrobials. Results: The performance characteristics of method were preliminarily determined (specificity, detection limits and stability). The test showed excellent specificity (no false positive); detection limits were determined for the four antibiotics in relation to their respective Maximum Residue Limit MRLs: Beta-lactams (penicillin G =MRL), tetracyclines (oxytetracycline =MRL), macrolides (erythromycin =MRL) and aminoglycosides (streptomycin >4 MRL); however, the sensitivity of bioassay for the streptomycin was unsatisfactory. Stability of the analytes in the matrix was adequate during the period evaluated. Conclusions: The preliminary bioassay method evaluated is applicable to the detection of a broad range of antimicrobial residues in bovine muscle at concentrations at the MRLs.

Keywords : antimicrobial residues; Maximum Residue Limit MRLs; bioassay.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )