CRUZ SUAREZ, Erika Carolina et al. Factors associated with ultrasound-guided insertion and use of peripheral central venous catheter. av.enferm. [online]. 2024, vol.42, n.2, 116357.  Epub Dec 31, 2024. ISSN 0121-4500.  https://doi.org/10.15446/av.enferm.v42n2.116357.

Objective

To identify clinical factors associated with the ultrasound-guided insertion and use of the peripherally inserted central catheters (PICCs).

Materials and method

A longitudinal, retrospective observational cohort study was conducted following the echo-guided insertion of PICCs by intensive care nurses. Data from 762 procedures were analyzed. Statistical analyses included descriptive methods and logistic regression to explore the relationship between dwell time and clinical variables, including complications.

Results

The primary indication for catheter insertion was difficult vascular access (33.6%), followed by chemotherapy and antibiotic therapy administration (26.6%). In 85.2% of cases, insertion was successful on the first attempt, with a median dwell time of 11 days. No complications related to the insertion procedure were reported. Complications associated with maintenance were low (7.8% due to infections and 6.6% due to mechanical failure) but were significantly associated with dwell time (p < 0.001). The analysis revealed that age was negatively correlated with dwell time, whereas insertion into the right basilic vein, the use of chemotherapy, and the presence of an infectious process were positively associated (p < 0.001; 95% CI).

Conclusions

First-puncture success rates were comparable to those reported in similar studies. Mechanical failure and infections were significant factors affecting catheter dwell time. Key factors influencing catheter life were identified, including age, chemotherapy indication, and insertion into the right basilic vein.

Keywords : Vascular Access Devices; Ultrasonics; Nursing Care; Infusions, Intravenous; Catheterization, Peripheral.