vol.23 número1CARACTERIZACIÓN DEL ESTADO NUTRICIONAL Y LA ACTIVIDAD FÍSICA EN UNA POBLACIÓN DE PILOTOS DE ALA FIJA Y ROTATIVA EN LA CIUDAD DE BOGOTÁ (COLOMBIA)¿"SUTILEZAS" DE LA DISCRIMINACIÓN Y LA VIOLENCIA BASADA EN EL GÉNERO?: SITUACIÓN DE LOS Y LAS ESTUDIANTES DE PREGRADO Y POSGRADO DE UNA FACULTAD DE MEDICINA EN BOGOTA D.C. índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • No hay articulos similaresSimilares en SciELO
  • En proceso de indezaciónSimilares en Google

Compartir


Revista Med

versión impresa ISSN 0121-5256

Resumen

CHILA M, L et al. METHODS FOR IDENTIFICATION OF ANTIGEN HLA-B27 HISTOCOMPATIBILITY: FOUR TECHNICAL COMPARISONS OF PROTOCOLS. rev.fac.med [online]. 2015, vol.23, n.1, pp.19-26. ISSN 0121-5256.  https://doi.org/10.18359/rmed.1326.

Introduction: The association between HLA-B27 and spondyloarthritis has made clear the fact that identification of HLA-B27 antigen is considered as a support in the diagnosis of these diseases. The most commonly used methods for determination of the HLA-B27 antigen in clinical laboratories as well as in their research, are microlymphocytotoxicity (MCTX), digital flow cytometry (CMFd), analogous flow cytometry (CMFa) and the Single Specific Primer-Polymerase Chain Reaction (PCRSSP). Objective: compare the CMFd against MCTX, CMFa against CMFd and CMFd against PCR-SSP. Methods: 4109 requests for HLA-B27 were analyzed with manifestations suggestive of SpA submitted between 2009 and 2012 at Hospital Militar Central and Instituto de Referencia Andino. To analyze the frequencies Chi square (X2) was evaluated; to estimate the methodological concordance the intraclass correlation coefficient (ICC) was used. All proposed analyzes were performed with SPSS V18. Results: 467 data obtained by CMFa versus PCR-SSP evaluated the CMFA showed 239 results between positive and indeterminate range, which, after being confirmed by molecular biology (PCRSSP), only 213 showed the expression of HLA-B27 (p <0.05). PCR-SSP and CMFd performed 208 results simultaneously, showing a high correlation between these techniques (p <0.05). To evaluate the correlation between CMFd and MCTX, 34 data were analyzed, revealing a 100% match on the positive results from these two methodologies (ICC = 1, p <0.05). Conclusion: The digital flow cytometry is a rapid method that presents a highly reliable for the initial identification of HLA-B27; results confirmed by PCR SSP recommend performance.

Palabras clave : HLA-B27 antigen; microlymphocytotoxicity (MCTX) cytometry (CMFd and CMFa); PCR-SSP.