SciELO - Scientific Electronic Library Online

 
vol.18 issue2Anatomopathologic study of Leptospira spp., isolated in Nicaragua in Mesocricetus auratus as biomodelBiogeographical affinities of Colombian Caribbean and Pacific galateoids (Decapoda: Anomura) author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Revista MVZ Córdoba

Print version ISSN 0122-0268

Abstract

MAIGUAL E, Yemall; SANCHEZ O, Iván  and  MATSUMOTO, Tsunao. Performance of sedimentation tanks in a recirculating system for tilapia production. Rev.MVZ Cordoba [online]. 2013, vol.18, n.2, pp.3492-3500. ISSN 0122-0268.

Objective. To compare the removal efficiency of solids, turbidity and apparent color between a conventional and a column settling tanks in a recirculating aquaculture system (RAS) for tilapia farming. Materials and methods. Tilapia with a stocking density between 30 and 33 kg/m3 were cultured in a RAS consisting of a water level control box, PVC piping system, three plastic tanks for culture, conventional horizontal flow settling tank (Con.ST), column vertical flow settling tank (Col.ST), three phase fluidized bed reactor, oxygen transfer reactor, air compressor, air blower, centrifugal pump. The Con.ST operated at a volume of 1.4 m3 and hydraulic retention time (HRT) of 2.94 h; and was drained weekly for washing and sludge collection, representing a 55%discharge of system water volume. The Col.ST operated with a volume of 0.30 m3 and HRT of 0.553 h. Three daily partial draining operations were executed, representing a discharge of 50% of the system volume. Results. The mean solids removal efficiencies were: 34.01 and 44.44%for total solids; 64.45 and 71.71% for suspended solids; 21.10 and 45.65% volatile solids; 65.51% and 62.79% for turbidity; and 56.37 and 50.91% for apparent color, respectively for Con.ST and Col.ST. Conclusions. The two settling devices are useful on removal of the studied parameters and presented similar performance on turbidity and apparent color removal; however, the Col.ST was more efficient than Con.ST for solids removal, requires less space, less volume and requires less discharge water volume, displaying feasibility for its use on RAS.

Keywords : Aquaculture; gravimetry; recirculation; tilapia; RAS.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )