SciELO - Scientific Electronic Library Online

 
vol.22 issue2Technical evaluation for the proposal of a different cricondentherm limit for the Caribbean coast within Colombian gas quality regulations author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Ingeniería y Universidad

Print version ISSN 0123-2126

Abstract

QOSIM, Nanang; SUPRIADI, Sugeng; SHAMSUDDIN-SARAGIH, Agung  and  WHULANZA, Yudan. Surface treatments of ti-alloy based bone implant manufactured by electrical discharge machining. Ing. Univ. [online]. 2018, vol.22, n.2, pp.59-70. ISSN 0123-2126.

Objective:

This research aims to observe the extent to which several surface treatment techniques increase the surface roughness of titanium alloy implants which was manufactured via electrical discharge machining (EDM). The effects of these techniques were also observed to decrease the Cu content on the implant surface.

Materials and Methods:

In this research, ultrasonic cleaning, rotary tumbler polishing, and brushing were employed as techniques to increase the roughness of a titanium implant which was manufactured via EDM, to the moderately rough category, and to reduce the contaminant element deposited on its surface. An MTT (3-(4,5-dimethylthiazol-2-yl)-2,5- diphenyltetrazolium bromide) assay test was also used to observe the effect of these engineered specimens with respect to mesenchymal stem cells’ proliferation.

Results and Discussion:

The results show that ultrasonic cleaning and rotary tumbler polishing created a significant increase (90% and 67%, respectively) in the surface roughness. On the other hand, brushing was shown to be the best benchmark for reducing the contamination of Copper (Cu). Furthermore, rotary tumbler polishing and brushing can increase the percentage of living cells compared to the original surface EDM specimens.

Conclusion:

All micro-finishing methods that were employed are able to increase the surface roughness of Ti alloy based- implant to moderately rough category.

Keywords : Surface roughness; cells proliferation; Ti-alloy implant; ultrasonic cleaning; rotary tumbler polishing; brushing.

        · text in English     · English ( pdf )