SciELO - Scientific Electronic Library Online

 
vol.19 número37Homogeneous and heterogeneous catalysts of Fe3+, Co2+ and Cu2+ for the degradation of methyl parathion in diluted aqueous mediumA control system for reducing the hydrogen consumption of PEM fuel cells under parametric uncertainties índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


TecnoLógicas

versão impressa ISSN 0123-7799versão On-line ISSN 2256-5337

Resumo

GONZALEZ-BARAJAS, Javier E.; VELANDIA, Cristian C.; LYMA-GUAQUETA, Jeysson  e  OSPINA-FUENTES, Pedro. Spectral analysis through filter banks aplied to preprocessing oriented to thresholding of pulse oximetry signal. TecnoL. [online]. 2016, vol.19, n.37, pp.29-43. ISSN 0123-7799.

The pulse oximetry signal (SPO2), allows the calculation of the oxygen saturation level in the blood, and it is acquired over the index finger of the patient. Under normal conditions, the variations in SPO2 have correlated with heart rhythm and its maximum value is in phase with the R wave in electrocardiographic signal (ECG). This property enables the SPO2 signal to be the basis for an alternative method for estimating the instantaneous heart rate. For measuring the instantaneous heart rate from the SPO2, it is necessary to carry out a signal thresholding process for detecting peak values in phase with the R-wave of the cardiac complex. In this paper, an iterative solution method is proposed to establish the cutoff frequency selection for the design of digital filters that allow detection of the maximum values of the signal pulse oximetry. The results obtained from the implementation of filter banks, demonstrated their ability to obtain versions of the pulse oximetry signal and frequency values of the spectral components, associated with the maximum values of the SPO2. Experiments used the CAPNOBASE processed signals database, which contains SPO2 and ECG signals, acquired simultaneously. The results allowed to verify that the filter bank allows to select the appropriate version of SPO2 signal with positive peaks, in phase with the R wave of the ECG signal.

Palavras-chave : .

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons