SciELO - Scientific Electronic Library Online

 
vol.21 issue42Implementation of an analytical formulation for LEMP to assess the lightning performance of a distribution lineExperimental characterization of compact fluorescent lamps for harmonic analysis of power distribution systems author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


TecnoLógicas

Print version ISSN 0123-7799On-line version ISSN 2256-5337

Abstract

LOPERA-MAZO, Edwin H.  and  ESPINOSA, Jairo. Secondary voltage regulation based on average voltage control. TecnoL. [online]. 2018, vol.21, n.42, pp.63-78. ISSN 0123-7799.  https://doi.org/10.22430/22565337.779.

This paper compares a conventional Secondary Voltage Regulation (SVR) scheme based on pilot nodes with a proposed SVR that takes into account average voltages of control zones. Voltage control significance for the operation of power systems has promoted several strategies in order to deal with this problem. However, the Hierarchical Voltage Control System (HVCS) is the only scheme effectively implemented with some relevant applications into real power systems.

The HVCS divides the voltage control problem into three recognized stages. Among them, the SVR is responsible for managing reactive power resources to improve network voltage profile. Conventional SVR is based on dividing the system into some electrically distant zones and controlling the voltage levels of some specific nodes in the system named pilot nodes, whose voltage levels are accepted as appropriate indicators of network voltage profile.

The SVR approach proposed in this work does not only consider the voltage on pilot nodes, but it also takes the average voltages of the defined zones to carry out their respective control actions. Additionally, this innovative approach allows to integrate more reactive power resources into each zone according to some previously defined participation factors.

The comparison between these strategies shows that the proposed SVR achieves a better allocation of reactive power in the system than conventional SVR, and it is able to keep the desired voltage profile, which has been expressed in terms of network average voltage.

Keywords : Secondary Voltage Regulation; Average voltage; Conventional SVR; Hierarchical Voltage Control System; Power System.

        · abstract in Spanish     · text in English     · English ( pdf )