SciELO - Scientific Electronic Library Online

 
vol.23 número49Considerations for Making 3D Print Face Shields - Covid19Influence of Turbulence, Density, Phase Change, and Phase Interfaces Models on the Performance of the Numerical Simulation of a Two-Phase Closed Thermosyphon índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


TecnoLógicas

versão impressa ISSN 0123-7799versão On-line ISSN 2256-5337

Resumo

VALDERRAMA-HINCAPIE, Sarah et al. Beta, gamma and High-Frequency Oscillations characterization for targeting in Deep Brain Stimulation procedures. TecnoL. [online]. 2020, vol.23, n.49, pp.13-34. ISSN 0123-7799.  https://doi.org/10.22430/22565337.1564.

Deep Brain Stimulation (DBS) has been successfully used to treat patients with Parkinson’s Disease. DBS employs an electrode that regulates the oscillatory activity of the basal ganglia, such as the subthalamic nucleus (STN). A critical point during the surgical implantation of such electrode is the precise localization of the target. This is done using presurgical images, stereotactic frames, and microelectrode recordings (MER). The latter allows neurophysiologists to visualize the electrical activity of different structures along the surgical track, each of them with well-defined variations in the frequency pattern; however, this is far from an automatic or semi-automatic method to help these specialists make decisions concerning the surgical target. To pave the way to automation, we analyzed three frequency bands in MER signals acquired from 11 patients undergoing DBS: beta (13-40 Hz), gamma (40-200 Hz), and high-frequency oscillations (HFO - 201-400 Hz). In this study, we propose and assess five indexes in order to detect the STN: variations in autoregressive parameters and their derivative along the surgical track, the energy of each band calculated using the Yule-Walker power spectral density, the high-to-low (H/L) ratio, and its derivative. We found that the derivative of one parameter of the beta band and the H/L ratio of the HFO/gamma bands produced errors in STN targeting like those reported in the literature produced by image-based methods (<2 mm). Although the indexes introduced here are simple to compute and could be applied in real time, further studies must be conducted to be able to generalize their results.

Palavras-chave : Deep Brain Stimulation; microelectrode recording; biomedical signal processing; Parkinson’s disease; subthalamic nucleus.

        · resumo em Espanhol     · texto em Inglês     · Inglês ( pdf )