SciELO - Scientific Electronic Library Online

 
vol.44 número172Validación de un método analítico por GC-FID para la cuantificación de estireno y α-metilestirenoComparación de la composición y de la actividad antioxidante del aceite esencial de manzanilla (Matricaria chamomilla L.) obtenido mediante extracción con fluidos supercríticos y otras técnicas verdes índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • No hay articulos similaresSimilares en SciELO
  • En proceso de indezaciónSimilares en Google

Compartir


Revista de la Academia Colombiana de Ciencias Exactas, Físicas y Naturales

versión impresa ISSN 0370-3908

Resumen

GUARIN, Paula; CRISTANCHO, Jonatan  y  CASTILLO, John J.. Rapid electrochemical detection of Staphylococcus aureus based on screen-printed gold electrodes modified with cysteine and Guinea grass (Panicum maximum) peroxidase. Rev. acad. colomb. cienc. exact. fis. nat. [online]. 2020, vol.44, n.172, pp.835-844.  Epub 23-Jul-2021. ISSN 0370-3908.  https://doi.org/10.18257/raccefyn.1019.

We present a novel electrochemical method for a rapid analytical detection of Staphylococcus aureus in culture and spiked milk samples through hydrogen peroxide (H2O2) consumption on a screen-printed gold electrode (SPGE) modified with cysteine and peroxidase from Guinea grass leaves (GGP). This peroxidase (POD) had a specific activity of 470 U mg-1 and it was immobilized on an SPGE surface previously modified with cysteine. Cyclic voltammograms of gold electrodes modified with peroxidase and cysteine in the presence of potassium ferrocyanide as a redox probe demonstrated an increase of approximately 5% in the current compared to the bare gold electrode. The SPGE modified electrode exhibited a good electrocatalytic response towards H2O2 reduction. We added a constant H2O2 concentration of 1x10-3 M to the culture medium and measured the decrease in the H2O2 current at -780 mV consumed by catalase from S. aureus. Our modified electrode proved to sense S. aureus in a range concentration between 3x102 and 3x108 CFU/mL-1 with a detection limit of 102 CFU/mL-1, detection time of about ~20 min, and a sensitivity of 0.020 mA CFU-1.

Palabras clave : Guinea grass peroxidase; Staphylococcus aureus; Electrochemical detection; Screen-printed electrodes.

        · resumen en Español     · texto en Inglés     · Inglés ( pdf )