SciELO - Scientific Electronic Library Online

 
vol.16 número1EVALUATION OF THE DIAGNOSTIC PRECISION OF FINE NEEDLE PUNCTURE ASPIRATION IN PATIENTS WITH THYROID NODULEEPIDEMIOLOGICAL SITUATION OF POISSONING WITH CHEMICAL SUBSTANCES IN THE DEPARTMENT OF META-COLOMBIA, PERIOD 2009-2014 índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Biosalud

versão impressa ISSN 1657-9550

Resumo

SIMANCAS PALLARES, Miguel  e  AREVALO TOVAR, Luisa. PERFORMANCE OF FOUR STATISTICAL METHODS FOR THE ASSESSMENT OF TEST RE-TEST RELIABILITY OF CONTINUOUS VARIABLES IN A SAMPLE. Biosalud [online]. 2017, vol.16, n.1, pp.19-29. ISSN 1657-9550.  https://doi.org/10.17151/biosa.2017.16.1.4.

Objective: To compare the performance of four statistical tests in continuous variables test/retest reliability assessment. Methods: Statistical simulation study developed in the framework of an in vitro diagnostic test study including 120 teeth which met the inclusion criteria. Each tooth was positioned in a standardization device and was taken two digital x-rays (T0 and T1) in which we assessed tooth-length. Data were analyzed with descriptive statistics and then a statistical comparison was done with paired Student's "t" test, intraclass correlation coefficient, Pearson correlation coefficient and Lin's concordance correlation coefficient in Stata v.13.2 for Windows (StataCorp., TX., USA). Results: The average dental length for T0 was 21.15 mm and for T1 21.07 mm. Student's "t" test revealed an average difference of 0.089 (P=0.00). The intraclass correlation coefficient 0.877 (95% CI: 0.43 - 0.98), Pearson's productmoment correlation coefficient 0.93, and Lin's concordance correlation coefficient 0.93 (95% CI: 0.908 - 0.956). Conclusions: Selection of a statistical test for test/re-test reliability assessment should be made having in mind the research objectives in any context and the possibility of each method for error assessment. Thus, a method that currently complies with this essential requirement is Lin's concordance correlation coefficient, which is recommended for future test re-test research studies.

Palavras-chave : reproducibility of results; statistics and numerical data; error; hypothesis-testing.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons