SciELO - Scientific Electronic Library Online

 
vol.19 issue36Caenorhabditis elegans as an infection model for the study of antimicrobialsRelationship of body composition and speed of cognitive processing in college students. A cross-sectional study author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Nova

Print version ISSN 1794-2470

Abstract

INSIGNARES ORDONEZ, Salvador; DIAZ CABALLERO, Antonio; BELENO QUINTERO, Yureinys  and  INSIGNARES BUELVAS, Salin. Fracture resistance of analogally made dental crowns vs cad-cam technology. In vitro study. Nova [online]. 2021, vol.19, n.36, pp.133-142.  Epub Jan 17, 2022. ISSN 1794-2470.  https://doi.org/10.22490/24629448.5296.

Background.

The fracture resistance of the crowns may have an influence on their appearance, according to the method of making them, either analogously or by means of Cad-Cam technology.

Objective.

To compare the resistance to the fracture of the individual crowns made by two manufacturing methods, under computer-aided design and computerized manufacturing (CAD-CAM) and injected.

Methods.

In vitro study. Sample size 20 crowns in two groups: 10 crowns using CAD-CAM technology and 10 crowns injected. Crowns were subjected to compressive loads in a universal testing machine, with a speed of 1mm / min and a cell load of 5kN until obtaining the maximum bill for these. Data were statistically analyzed using the Shapiro Wilk tests, Mann Whitney p = 0.05.

Results.

Crowns manufactured by Cad-Cam obtained a minimum of 602.5 Newton and a maximum of 1093 Newton, while the crowns manufactured analogously obtained a minimum of 525.2 Newton and a maximum of 1773 Newton in the experiment with the machine Universal test to achieve their fracture. A significant difference was obtained in the invoice resistance test between both manufacturing methods (p <0.001).

Conclusion.

Pressed Lithium Disilicate crowns obtained higher fracture resistance than crowns under design and manufacturing by computer (CAD-CAM).

Keywords : (mesh database): dental crown; flexural strength; dentistry; tooth preparation, prosthodontic; laboratories, dental.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )