SciELO - Scientific Electronic Library Online

 
vol.14 issue1SEISMIC GEOHISTORY AND DIFFERENTIAL INTERFORMATIONAL VELOCITY ANALYSIS IN THE ANAMBRA BASIN, NIGERIAACTIVITY AND Vp/Vs RATIO OF VOLCANO-TECTONIC SEISMIC SWARM ZONES AT NEVADO DEL RUIZ VOLCANO, COLOMBIA author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Earth Sciences Research Journal

Print version ISSN 1794-6190

Abstract

AYOLABI, Elijah A.; FOLORUNSO, Adetayo F.  and  OBENDE PHILLIPS, W.. INTEGRATED ASSESSMENTS OF POSSIBLE EFFECTS OF HYDROCARBON AND SALT WATER INTRUSION ON THE GROUNDWATER OF IGANMU AREA OF LAGOS METROPOLIS, SOUTHWESTERN NIGERIA. Earth Sci. Res. J. [online]. 2010, vol.14, n.1, pp.100-110. ISSN 1794-6190.

Vertical electrical sounding (VES) and Induced Polarisation (IP) methods of geophysical survey were incorporated with physiochemical analysis of well water samples to determine vertical extent of petroleum-product contamination in subsurface soils and groundwater from bulk-fuel storage and distribution terminals in Iganmu area of Lagos. Interpreted results of VES and IP revealed four geoelectric layers. Clay with resistivity and IP values ranging from 1.5-14 Qm and 50 - 400mV/V respectively was encountered at the last layer penetrated by the survey except in four VES stations where the clay horizon was delineated at the third layer. This implies that subsurface aquifer is sealed by impervious layer which possibly prevents it from being contaminated by hydrocarbon and other refuse materials from the surface. Borehole log and electrical resistivity survey from a control site within the area were also incorporated with the geophysical measurements and these confirm lithologic similarity and the presence of a sealant above the aquifer layer. In addition to this, the results of the physical and geochemical analyses carried out on groundwater samples from shallow wells within the pack show very negligible level of hydrocarbon contamination which has no serious environmental implications on subsurface water in the area. However, electrical conductivity, salinity and TDS values obtained show high level of dissolved minerals (salts) making the water highly saline and unsuitable for drinking being far above recommended values for drinking water. We thus inferred that Lagos lagoon must have invaded the aquifer in some places leading to high salinity observed.

Keywords : contamination; hydrocarbon; electrical resistivity; physiochemical; IP sounding.

        · abstract in Spanish     · text in English     · English ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License