SciELO - Scientific Electronic Library Online

 
vol.13 issue2Incorporation of escape gap in traps for crab, Ciénaga Grande de Santa Marta, ColombiaNitrogen transformation during the composting of horse bosta author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Producción + Limpia

Print version ISSN 1909-0455

Abstract

RAMOS ASCUE, Juan Diego. Online measurement of the DQO by correlation of the spectral absorption coefficient of uv light. Rev. P+L [online]. 2018, vol.13, n.2, pp.67-76. ISSN 1909-0455.  https://doi.org/10.22507/pml.v13n2a8.

Introduction:

The organic material is a source of damage to the environmental and superficial water, nevertheless, the direct and continuous measurement of this, either COT, BOD, or COD, is difficult and has a relatively high cost. A method currently used to monitor the organic material in real time is by means of the spectral absorption coefficient at a wavelength of 254nm (SAC254).

Objective:

Evaluate the precision of measurement and the level of correlation between COD and the value of SAC254.

Materials and methods:

Two practical tests of organic measurement systems with this technology (SAC254) were carried out, a test was conducted in a domestic wastewater treatment plant owned by SEDAPAL and another in an industrial wastewater treatment plant owned by PROTISA. The measurement system employed included an in-line sensor with SAC254 and a data logger capable of correlating parameters SAC254 and COD.

Results:

An average error of 13% was observed in the measurement system, the SAC254 proved to be a practical tool in terms of easy handling, reagent-free and suitability for use in both domestic and industrial wastewater.

Conclusion:

The measurement system installed allowed us to verify that there is indeed a direct relationship between the SAC254 factor and the COD, as SAC254 increased, it also increased the COD value and vice versa, therefore it is a good indicator that would optimize efficiency of the process and execute an effective control.

Keywords : organic material; spectral absorption; control; measurement; COD.

        · abstract in Spanish | Portuguese     · text in Spanish     · Spanish ( pdf )