vol.41 número3Traqueostomía percutánea por dilatación sin fibrobroncoscopio. Evaluación de 80 casos en cuidados intensivosImpacto de las facultades de medicina y de los estudiantes sobre los resultados en la prueba nacional de calidad de la educación superior (SABER PRO) índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • No hay articulos similaresSimilares en SciELO
  • En proceso de indezaciónSimilares en Google

Compartir


Colombian Journal of Anestesiology

versión impresa ISSN 0120-3347

Rev. colomb. anestesiol. vol.41 no.3 Bogotá jul./set. 2013

https://doi.org/10.1016/j.rca.2013.05.011 

http://dx.doi.org/10.1016/j.rcae.2013.05.012

Scientific and Technological Research

 

Correlation and agreement between arterial and central venous blood pH, P02) PC02 and HC03- values of mechanically ventilated patients in intensive care unit: A prospective observational study

Correlación y concordancia entre los valores de pH, P02, PC02 y HC03- en sangre arterial y venosa de pacientes con ventilación mecánica en la unidad de cuidados intensivos

Mohd Sabihul Islama, S. Moied Ahmedb,*, S. Banoc, Abu Nadeemd, Mozammil Shafia

a MD (Anaesthesia), Senior Resident (Anaesthesia), Department of Anaesthesiology, JN Medical College, AMU, Aligarh, India
b MD, PhD (Anaesthesia), Professor (Anaesthesia), F1CCM, FCCP, F1MSA, Department of Anaesthesiology, JN Medical College, AMU,Aligarh, India
c MD (Anaesthesia), Professor (Anaesthesia), Department of Anaesthesiology, JN Medical College, AMU, Aligarh, India
d MD (Anaesthesia), Assistant Professor (Anaesthesia), Department of Anaesthesiology, JN Medical College, AMU, Aligarh, India

* Please cite this article as: Islam MS, et al. Correlación y concordancia entre los valores de pH, P02, PC02 y HCO3 en sangre arterial y venosa de pacientes con ventilacion mecanica en la unidad de cuidados intensivos. Rev Colomb Anestesiol. 2013.

** Research credited to: Intensive Care Unit, Department of Anaesthesiology, JN Medical College, AMU, Aligarh, India.

* Corresponding author at: Department of Anaesthesiology, JN Medical College, AMU, Aligarh, India. E-mail address: sma99@rediffmail.com (S.M. Ahmed).

2256-2087/$ - see front matter © 2012 Sociedad Colombiana de Anestesiología y Reanimación. Published by Elsevier España, S.L. All rights reserved.


ARTICLE INFO

Article history: Received 13 October 2012 Accepted 20 May 2013 Available
online 16 July 2013

Abstract

Background: The procedure for arterial blood sampling can be technically difficult with limitations and complications.

Aims: To evaluate the correlation and agreement between arterial and central venous blood pH, PO2, PCO2 and HCO3- values and infer whether central venous blood gas (CVBG) values could replace arterial blood gas (ABG) values. Design: Prospective observational study.

Methods and Material: A total of 100 samples were collected from 50 adult normotensive and normothermic patients requiring mechanical ventilation. Arterial blood was collected from radial artery and within 2 minutes central venous blood was withdrawn from the same patient. Correlation and agreement was tested using Pearson's Correlation and Bland Altman Analysis.

Results: The pH, PO2, PCO2 and HCO3- of CVBG correlated significantly with arterial values (rpH = 0.88, p < 0.001; rpo2 = 0.358, p <0.05; rpco2 = 0.470, p < 0.001 and Thco3 =0.714, p < 0.001). Regression equations were derived to predict AVG values from CVBG values as follows: Arterial pH = 0.879 x central venous pH + 0.9422 (constant), arterial PO2 = 0.421 x central venous PO2 +114.4 (constant), R2 = 0.128, arterial PCO2 = 0.429 x central venous PCO2 + 24.627 (constant), R2 = 0.2205 and arterial HCO3 = 1.045 x central venous HCO3 + 3.402 (constant), R2 = 0.5101.The mean arterial minus venous difference forpH, PO2, PCO2, and bicarbonate was 0.053 ±0.014, 56.04 ±15.74, 2.20 ± 4.4 and 4.30 ±1.64 respectively. Bland-Altman plots for agreement of pH, PO2, PCO2, and bicarbonate showed 95% limits of agreement of -0.04 to 0.146, -52.51 to 164.59, -26.61 to 31.01 and -7.0 to 15.6, respectively.

ConcIusions: The arterial pH, PO2, PCO2 and HCO3- values correlated well with central venous values. However, only the arterial pH value can replace the central venous pH value.

© 2012 Sociedad Colombiana de Anestesiología y Reanimación. Published by Elsevier España, S.L. All rights reserved.

Keywords: Respiration artificial, Intensive care, Homeostasis, Acid-base equilibrium, Blood gas analysis


Resumen

Antecedentes: la toma de gases arteriales (GA) puede ser difícil con limitaciones y complicaciones.

Objetiuo: evaluar la correlación y concordancia entre valores de pH, PO2, PCO2 y HCO3- en sangre arterial y venosa central e inferir si valores de gases venosos centrales (GVC) pueden reemplazar valores de GA. Diseno:Estudio prospectivo observacional.

Materiales y Métodos: se tomaron 100 muestras en 50 pacientes adultos normotensos y nor-motérmicos, que requirieron ventilación mecánica. Los GA se tomaron de la arteria radial y 2 minutos después se tomaron los GVC. Se evaluó la correlación y concordancia utilizando la Correlación de Pearson y Análisis de Bland Altman.

Resultados: los valores venosos y arteriales de pH, PO2, PCO2 y HCO3- correlacionaron significativamente (rpH = 0.88,p<0.001;rpo2 = 0.358,p <0.05;rpco2 = 0.470,p <0.001y Thco3 =0.714, p < 0.001). Las ecuaciones que predicen los valores de GA a partir de valores de GVC, son: pH arterial = 0.879 x pH venoso central+ 0.9422; PO2 arterial = 0.421 x PO2 venoso central +114.4, R2 = 0.128, PCO2 arterial = 0.429 x PCO2 venoso central +24.627, R2 = 0.2205 y HCO3 arterial = 1.045 x HCO3 venoso central + 3.402, R2 = 0.5101. La diferencia media de GA menos GVC de pH, PO2, PCO2, y bicarbonato fue de 0.053 ± 0.014,56.04 ± 15.74,2.20 ± 4.4 y 4.30 ±1.64, respectivamente. Las gráficas de Bland-Altmanpara concordancia delpH, PO2, PCO2 y bicarbonato mostraron límites de concordancia del 95% de -0.04 a 0.146, -52.51 a 164.59, -26.61 a 31.01 y -7.0 a 15.6, respectivamente.

Conclusiones: hubo correlación entre los valores de GA y GVC de pH, PO2, PCO2 y HCO3-. Sin embargo, solamente el pH venoso puede reemplazar el pH arterial.

© 2012 Sociedad Colombiana de Anestesiología y Reanimación. Publicado por Elsevier España, S.L. Todos los derechos reservados.

Palabras clave: Respiración artificial, Cuidados intensivos, Homeostasis, Equilibrio ácido-base, Análisis de los gases de la sangre


Introduction

Arterial blood gas (ABG) analysis represents the gold standard for determining acid-base status of a mechanically ventilated patient.1 The procedure at times can be technically difficult with various limitations and complications.2-5

The information obtained from an ABG report can also be obtained from venous blood sampling.6 Central venous access is almost a routine and mandatory procedure in OT, ICU, Accident and Emergency unit. It can therefore be a much easier, quicker and less complicated method of identifying venous blood gas status of the patient.3,6

However, in order to replace ABG values with central venous blood gas (CVBG) values we need to first find a correlation and agreement between the two blood gas values.

Previous studies have examined the relationship between arterial and central venous gas samples. Most of those studies were disease specific. They have dealt with either agreement or correlation of one or two blood gas parameters. Further, the inference of most of the studies was not in congruence with each other.6-10

Hence, the aim of the present study was to evaluate the correlation and agreement between arterial and central venous blood pH, PO2, PCO2 and HCO3- values in medical and surgical patients admitted in the ICU and infer whether central venous blood gas could replace arterial blood gas.

Subjects and methods

The study was conducted in the ICU of a Medical College Hospital. Ethical clearance was obtained from departmental ethical committee. 50 adult patients including both sexes, age ranging between 20 and 50 yrs and requiring mechanical ventilation were enrolled in the study. Informed consent was obtained from the patients nearest relatives. No patient was included twice for the study.

The blood (1 ml) was collected simultaneously from either radial or femoral artery and central vein of the same patient by two different observers so as to avoid difference in sample collection time. The sample was drawn in two separately labelled pre-heparinised syringes and immediately analysed in the ABG machine (Eschweiler Combisys 2 analyser) kept in the ICU, so as to avoid maintenance of cold chain with ice.

A total of 100 samples (50 ABG plus 50 CVBG) were analysed. the PO2, PCO2, pH and HCO3-, were recorded from the ABG report and evaluated for the study. Additional data recorded were: the Diagnosis of the disease, Ventilator setting, Heart Rate, mean arterial pressure (MAP), arterial oxygen saturation (SpO2), temperature, hemogram, and renal profile. Patients with severe hypotension, severe sepsis, trauma in hands, no central venous access and hypothermia (<36 °C) were not included in the study.

All statistical analysis were done using SPSS version 17. A sample size of 50 in each group was based on power analysis in which alpha level was fixed at 0.05, anticipated effect size (Cohen's d) of 0.8 and for a desired statistical power level of 0.8, a minimum required sample size per group was calculated to be 26 and minimum total required sample size was calculated to be 52. Pearson correlation test was used to measure the correlation significance (p <0.05) and regression analysis was used to calculate the regression equation between arterial and central venous values. Bland-Altman analysis was used to find the agreement between arterial and central venous pH, PO2, PCO2 and HCO3-. The A - V (arterial - venous) difference versus the average value ([A + V]/2) was plotted. Means, SDs and 95% prediction intervals (limits of agreement) were evaluated (A = arterial parameter, V = central venous parameter). The predefined value for acceptable limits of agreement (LOA) for pH was -0.05 to +0.05, for pCO2 -10 to +10, for pO2 -10 to +10 and for HCO3 was -2 to +2.

Results

The demography and the diagnosis of the patients are shown in Table 1.

ThepH, PO2, PCO2 and HCO3- of central venous (CVBG) correlated significantly with arterial values (rpH = 0.88, p < 0.001; rPO2 = 0.358, p <0.05; rPCO2 = 0.470, p < 0.001 and rHCO3 = 0.714, p < 0.001) (Tables 2-5 and Figs. 1-4). The correlation was quantified by calculating regression equation for each parameter as mentioned below:

Arterial pH = 0.879 x central venous pH + 0.9422(constant), R2 = 0.78

Arterial PO2 = 0.421 x central venous PO2 +114.4 (constant), R2 = 0.128

Arterial PCO2 = 0.429 x central venous PO2 + 24.627 (constant), R2 = 0.2205

Arterial HCO3 = 1.045 x central venous HCO3 +3.402 (constant), R2 = 0.5101

The mean difference and 95% limits of agreement were calculated using Bland-Altman analysis to assess the agreement between two variables. The value of mean difference was small (0.053 ± 0.014) and value of 95% limits of agreement was narrow (-0.04 to 0.146) for pH in ABG and CVBG and showed good agreement. However, value of mean difference

was large and value of 95% limits of agreement was too wide for PO2, PCO2 and HCO3- of ABG and CVBG, which indicated poor agreement (Table 6). The bias plotting using Bland-Altman analysis is shown in Figs. 5-8.

Discussion

In the present study the correlation between pH of ABG and CVBG was significant, with narrow 95% limits of agreement (LOA). This probably indicated an acceptable agreement between pH of ABG and CVBG, which was in accordance to the previous authors.7-10 However, Malinoski et al. in 20056 evaluated a poor LOA between pH of CVBG and ABG although the correlation was statistically signiicant.

Similarly, the correlation between PCO2 of ABG and CVBG was statistically significant (p < 0.001) but the 95% limits of agreement were poor. This was in accordance to the observation of Malinoski et al.6 and Adrogue et al.7 However, contrary to our indings, Treger et al.9 showed good agreement between

PCO2 of ABG and CVBG samples. They demonstrated that the mean arterial minus venous (A- V) difference for PCO2 was small with narrow 95% limits of agreement. They concluded that the peripheral or central venous PCO2 could replace their arterial equivalents in many clinical contexts encountered because they were in agreement with each other.

Middleton et al.8 determined the extent of agreement between CVBG and ABG values for HCO3- and showed acceptably narrow 95% limits of agreement. Similarly, Treger et al.9 examined the agreement between ABG and CVBG samples for HCO3- and demonstrated narrow 95% limits of agreement and concluded that HCO3- of CVBG could replace HCO3- of ABG in many clinical contexts in ICU. However, in our study the HCO3- in ABG and CVBG correlated significantly with each other and had small mean difference but the 95% limits of agreement was not significant. This was contrary to the observations of the previous author. The reason for this difference in finding in the present study could be probably due to small sample size and diverse group of patients. Previous studies mainly included specific group of patients including trauma,10 acute exacerbation of COPD,11 Diabetic ketoacidosis,12 etc. as against the diverse group of diseases included in our study.

The PO2 of ABG and CVBG correlated significantly with each other and had large mean difference and hence a poor agreement. Our observation could not be compared with others since to the best of our knowledge there has been no published literature on this. The significant correlation between arterial and central venous PO2 in our study could not be explained. However, their agreement was poor which was similar to other variables in our study.

There were certain weaknesses in our study which probably could be the reason for the differences in observation in comparison to the previous studies. It was a single centre study and the sample size could be smaller than some of the previous studies. However, the strength of the study was that we evaluated major acid base parameters of sufficiently powered population with the diverse disease process.

No study is free from bias. We tried to avoid biasness by analysing both the samples from the same ABG machine thus avoiding biasness or errors due to machine. The samples werecollected from mixed patient population (both surgical and medical patients). No patient was repeated for the study. This was done to avoid biasness of disease and patient specific.

Therefore, we conclude that although arterial pH, PO2, PCO2 and HCO3- values correlated well with central venous values only arterial pH value can be replaced by the central venous pH value. However, a further multicentre study with a large sample size may be conducted so as to avoid all the limitations of the present study.

Funding

None declared.

Conflicts of interest

The authors have no conflicts of interest to declare.

1. McGillivray D, Ducharme FM, Charron Y, Mattimoe C, Treherne S. Clinical decision making based on venous versus capillary blood gas values in the wellperfused child. Ann Emerg Med. 1999;34:58-63.         [ Links ]

2. Criscuolo C, Nepper G, Buchalter S. Reflex sympathetic dystrophy following arterial blood gas sampling in the intensive care setting. Chest. 1995;108:578-80.         [ Links ]

3. Giner J, Casan P, Belda J, Gonzalez M, Miraida RM, Sanchis J. Pain during arterial puncture. Chest. 1996;110:1443.         [ Links ]

4. Kelly AM, McAlpine R, Kyle E. Agreement between bicarbonate measured on arterial and venous blood gases. Emerg Med Australas. 2004;16:407-9.         [ Links ]

5. Mortensen J. Clinical sequelae from arterial needle puncture, cannulation, and incision. Circulation. 1967;35:1118-23.         [ Links ]

6. Malinoski DJ, Todd SR, Slone DR, Mullins RJ, Schreiber MA. Correlation of central venous and arterial blood gas measurements in mechanically ventilated trauma patients. Arch Surg. 2005;140:1122-5.         [ Links ]

7. Adrogue HJ, Rashad MN, Gorin AB, Yacoup J, Madias NE. Assessing acid-base status in circulatory failure. Difference between arterial and central venous blood. N Engl J Med. 1989;320:1312-6.         [ Links ]

8. Middleton P, Kelly AM, Brown J, Robertson M. Agreement between arterial and central venous values for pH, bicarbonate, base excess, and lactate. Emerg Med J. 2006;23:622-4.         [ Links ]

9. Treger R, Pirouz S, Kamangar N, Corry D. Agreement between central venous and arterial blood gas measurements in the intensive care unit. Clin J Am Soc Nephrol. 2010;5:390-4.         [ Links ]

10. Zahn RL, Weil MH. Central venous blood for monitoring pH and PCO2 in the critically ill patient. J Thorac Cardiovasc Surg. 1966;52:105-11.         [ Links ]