SciELO - Scientific Electronic Library Online

 
vol.41 issue2A Novel Dynamic and Fuzzy Value Stream Mapping (DFVSM): System Dynamics and Fuzzy Logic IntegrationThe Gender Gap in Engineering Programs in Colombia author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Ingeniería e Investigación

Print version ISSN 0120-5609

Ing. Investig. vol.41 no.2 Bogotá May/Aug. 2021  Epub June 17, 2021

https://doi.org/10.15446/ing.investig.v41n2.86742 

Original articles

Comparative Study of Theoretical and Real Deflection of Simple and Reinforced Concrete Joists

Estudio comparativo de la deflexión teórica y real de viguetas de concreto simple y reforzado

Socrates P. Muñoz-Perez1 
http://orcid.org/0000-0003-3182-8735

Angel A. Ruiz-Pico2 
http://orcid.org/0000-0003-2638-0593

Juan M. Anton-Perez3 
http://orcid.org/0000-0002-9665-779X

Dandy B. Roca-Loayza4 
http://orcid.org/0000-0002-0688-0120

1 Civil Engineer, Pedro Ruiz Gallo National University, Master in Earth Sciences with a major in Geotechnics, National University of San Agustín. Affiliation: Faculty of Engineering, Architecture and Urbanism, Professional School of Civil Engineering of Lord of Sipan University. Email: pedro_munoz19@hotmail.com

2 Geological Engineer, University of Granada, Doctor in Civil Engineering, Da Coruña University. Affiliation: Faculty of Engineering, Professional School of Environmental Civil Engineering of Santo Toribio de Mogrovejo University. Email: aaruizpico@gmail.com

3 Graduate in Statistics, Pedro Ruiz Gallo National University, Master of Science, Mention in Applied Statistics, National University of Trujillo. Affiliation: Faculty of Physical and Mathematical Sciences of the Pedro Ruiz Gallo National University. Lambayeque, Perú. Email: janton@unprg.edu.pe

4 Civil Engineer, Universidad Nacional San Luis Gonzaga, Master of Science with a major in Structural Engineering, National University of Engineering. Affiliation: Faculty of Engineering of the Autonomous University of Mexico. Email: dandyberlie@gmail.com


ABSTRACT

The objective of this research is to determine the real deflection of a concrete joist and correlate the result with theoretical deflection, which is based on a stress vs. deformation model which was proposed by Mander et al. (1988) for monotonic loads of reinforced and non-reinforced concrete. The construction of a concrete joist does not result in a 100% homogenous, isotropic, and linearly elastic element, since its production depends on many conditions, such as aggregate selection, water, cement manufacturing, tests performed for mixture design, the operator in charge of the mixture, and the construction of the joist. Therefore, research was carried out on the variation of real reflection with respect to theoretical calculations. To this effect, 30 simple-concrete and 30 reinforced-concrete joists were elaborated. They were tested by measuring their maximum deflection and comparing it to its theoretical counterpart. To calculate the theoretical deflection, a curvature moment diagram was elaborated with the RectMom software by Restrepo and Rodríguez (2012), which uses the model by Mander et al. (1988). Experimental results showed a greater deflection than the one reported by theoretical calculations.

Keywords: joist deflection; inelastic behavior; curvature moment

RESUMEN

Esta investigación tiene como objetivo determinar la deflexión real de una vigueta de concreto y correlacionar el resultado con la deflexión teórica, que está basada en el modelo esfuerzo vs. deformación propuesto por Mander et al. (1988) para cargas monótonas de concreto reforzado y no reforzado. La construcción de una vigueta con concreto no conforma un elemento 100 % homogéneo, isótropo y linealmente elástico, ya que su fabricación depende de muchas condiciones como la elección de los agregados, el agua, la fabricación del cemento, los ensayos realizados para el diseño de mezclas, el operario a cargo de la mezcla y la construcción de la vigueta. Por ello se investigó la variación de la deflexión real con respecto a los cálculos teóricos, para lo cual se fabricaron 30 viguetas de concreto simple y 30 viguetas de concreto armado, que se ensayaron midiendo la deflexión máxima y se comparándola con la teórica. Para el cálculo de la deflexión teórica se elaboró el diagrama de momentos de curvatura con el programa RectMom de Restrepo y Rodríguez (2012), que utiliza el modelo de Mander et al. (1988). Los resultados experimentales mostraron una deflexión mayor que los cálculos teóricos.

Palabras clave: deflexión en viguetas; comportamiento inelástico; momento de curvatura

Introduction

The calculation of deformations or deflections in reinforced concrete elements subjected to bending is important because these elements must have an adequate rigidity to eliminate any deformation along a structure, which constitutes a risk for its resistance or operation under service conditions (Carrillo and Silva-Páramo, 2016; Carrillo, Cárdenas Pulido, and Aperador, 2017).

Likewise, reinforced concrete elements are used when there is a deficit in any of the properties of a structure due to a new state of charge during its useful life. These increased loads generally result from the state of service for which these deflections must be controlled (Falope, Lanzoni, and Tarantino, 2019)

It is important to know the responses and resistant mechanisms present in a reinforced concrete element when subjected to different kinds of stress. These factors can be measured through experimental tests, which allows verifying the theories formulated by standards or studying other theories (Chiorean and Buru, 2017).

Carrying out this type of study is important because it will help us have a clearer perspective of real deflection (depending on compressive strength, applied load, reinforcement and geometry), which will allow adjusting the calculations. It is important to verify deformations in structural elements with little inertia to ensure the operation of the structure as a whole and not endanger human life (Hemn Qader, Dishad Kakasor, and Abdulkhaleq, 2020).

Regarding deflections and cracking, adequate service behavior can be achieved in beams with less than the maximum allowable by standard E 060 (L 300). For 200 x 300 mm beams with 290 cm of free length between supports and 30% of redistribution in negative steel, deformations of 7,90 mm of deflection and 0,35 mm of cracking were obtained (Ministerio de Vivienda, Construcción y Saneamiento, 2009).

For the comparison of both general models and simplified formulae, experimental data are required which adequately represent the magnitudes of the most significant variables of the structural elements with deformation problems, as well as sufficient complementary data to allow the theoretical analysis of the problem (Purushothama Raj and Ramasamy, 2012).

The only way to rationalize force and displacement factors is by quantifying the relationships of resistance and structural ductility through analytical studies and experimental tests, determining design forces and displacements in a more rational way (related theories) and contemporary trends in building code (Carrillo, Blandón Valencia, and Rubiano, 2013; Ismail et al., 2018).

Materials and methods

This research was experimental. Several mixtures were designed, whose compressive strength varied from f'c = 280 kg/cm2 up to 400 kg/cm2. The aggregates were from the quarries of Tres Tomas, Pátapo, and Batangrande, which are located in the Lambayeque region, as well as from Talambo, near Chepén, which belongs to the region of La Libertad. Using type I cement, the physical properties of these mixtures were studied for the purpose of preparing concrete mixtures. Simple and reinforced concrete joists were manufactured with dimensions of 15 cm x 15 cm x 53,5 cm, which were flexurally tested at 7, 14, and 28 days. At the same time, specimens were produced to obtain compressive strength at the same ages as the joist. A mix was designed for each quarry, and 02 joists were tested for each break, with 10 joists at 7, 14, and 28 days for both simple and reinforced concrete. The flexion of a total of 60 joists was therefore tested (Alhajri, Tahir, Azimi, Mirza, and Ragaee, 2016).

Figure 2 shows the molds used to manufacture the joists, Figure 3 shows the specimens of the tested joists, Figure 4 shows the bending test of the joist, and Figure 5 shows the break of the joist after being tested.

Source: Authors

Figure 1 Joist formwork. 

Source: Authors

Figure 2 Joist reinforcement. 

Source: Authors

Figure 3 Simple and reinforced joists. 

Source: Authors

Figure 4 Beam flexure test. 

Source: Authors

Figure 5 Joist fissure. 

The resistance design method, together with the use of higher resistance concrete and steels, has allowed the use of relatively slim elements. Consequently, deflections and deflection cracking have become more severe problems than they were a few decades ago (Hemn Qader, Dishad Kakasor, and Abdulkhaleq, 2020; Luo, et al., 2019).

One of the best ways to reduce deflections is by increasing the cant of the members, but the designers are always under pressure to keep the members with the cant as low as possible. Another solution is improving the quality of the material's resistance to deformation, in other words, increasing the elasticity modulus of the material. For this reason, it is necessary to have an adequate calculation of deflections, so as not to affect the resistance or functionality of the analyzed structure. If the designer decides not to use the minimum thicknesses given in Table 1, then he or she will be forced to determine the actual deflections, which must not exceed the values in Table 2.

Table 1 Cant or minimum thickness of non-prestressed beams or reinforced slabs in one direction unless deflections are calculated 

Source: Table 9.1 of Peruvian Building Standard E 060 (Ministerio de Vivienda, Construcción y Saneamiento, 2009).

Elastic methods are used to obtain and determine the equations to define the slope and elastic curve of a beam (Hamrat et al., 2020).

The lateral part of the surface of a deformed beam is called the elastic, deformed, or elastic curve of the beam. It is the curve that forms the longitudinal axis, which at the beginning was straight. As shown in Figure 6, it is in this section that we can deduce the elastic curve, which also allows us to determine the deflection of any point based on its length or X coordinate.

Source: Singer and Pytel (1994)

Figure 6 Elastic curve of a beam. 

The left end is the origin of the x axis, directed according to the initial direction of the beam without deforming, and the positive y axis upward. The deformations are so small that it is not possible to distinguish between the initial length and the projection of its already deformed length. Therefore, the elastic curve is very flat and its slope at any point is also very small.

Table 2 Maximum allowable deflections 

Source: Table 9.2 of Peruvian Building Standard E 060 (Ministerio de Vivienda, Construcción y Saneamiento, 2009).

Some structural analysis problems can be solved using linear analysis, but the geometric nonlinearity, the nonlinearity due to the behavior of the material, and the nonlinearity due to the boundary conditions change when posing and solving non-linear problems (Beléndez, Neipp, and Beléndez, 2002; Ismail et al., 2018).

Theoretical deflection

To make a prediction of the experimental displacement, the deflection was calculated from the analytical calculations described below.

The joists were modeled using the SAP2000 software with frame elements that can be used to model beams, columns, braces, and trusses in planar and three-dimensional structures. Nonlinear material behavior is available through frame hinges and includes the effects of biaxial bending, torsion, axial deformation, and biaxial shear deformations.

A frame element is modeled as a straight line connecting two points, and each element has its own local coordinate system for defining section properties and loads, as well as for interpreting output, as shown in Figure 7.

Source: Authors

Figure 7 Joist modeled with frame elements in the SAP2000 program. 

To consider inelastic behavior, a plastic hinge was located in the center of the span, which is the point where the greatest deformation occurs.

When nonlinear properties are present in the element, they only affect nonlinear analyses. Linear analyses starting from zero conditions (the unstressed state) behave as if the nonlinear properties were not present. Linear analyses using the stiffness from the end of a previous nonlinear analysis use the stiffness of the nonlinear property as it existed at the end of the nonlinear case (Alhajri et al., 2016; Luo et al., 2019)

Each hinge represents concentrated post-yield behavior in one or more degrees of freedom. Hinges only affect the behavior of the structure in nonlinear static and nonlinear time-history analyses.

Since the predominant behavior was bending, the M3 ball joint type was used, which was also in the program's library. Hinge properties can be computed automatically from the element material and section properties according to Federal Emergency Management Agency FEMA-356 or American Society of Civil Engineers ACSE 41-13 criteria (FEMA and ASCE, 2000). For our case, the properties were entered manually and obtained from the curvature moment diagram of the joist section.

To obtain the curvature moment diagram, the RectMom software (Rodriguez and Restrepo, 2012) was used. This application uses the model proposed by Mander et al. (1988) shown in Figure 8 for concrete modelling. This behavior allows the effect of the interaction between concrete and reinforcement bars by introducing tension reinforcement into the softening side of the curve (Sinaei, Mohd Zamin, and Mahdi, 2011).

Source: Mander et al. (1988)

Figure 8 Stress-strain model proposed for monotonic loading of confined and uncofined.  

Likewise, for the reinforcing steel, the Mander model was used, which is shown in Figure 9. This model considers three zones: the elastic zone, the creep zone, and the strain hardening zone.

Source: Mander et al. (1983)

Figure 9 Monotonic stress-strain curve typical of a rebar.  

Real Deflection

For the experimental deflection, the Peruvian Technical Standard NTP 339.079 testing method was applied to determine the flexural strength of concrete in simply supported beams with loads in the center of the span (Comisión de Normalización y Fiscalización de Barreras Comerciales no Arancelarias - INDECOPI, 2012).

The equipment to perform the test had to comply with the requirements of the sections based on the verifications, corrections, and the time interval between verifications. The mechanism by which loads are applied to the specimen employed one load application block and two specimen support blocks. The load was to be applied perpendicularly to the upper face of the beam, in such a way that eccentricities could be avoided (Comisión de Normalización y Fiscalización de Barreras Comerciales no Arancelarias - INDECOPI, 2012).

The specimens on which the tests were carried out had to be prepared according to the test method indicated above to meet the required compressive strength. The beam had a free span between supports approximately three times its height, with a tolerance of 2%. The lateral faces of the beam formed right angles with the upper and lower face. All surfaces were smooth and free of any porosity, according to Figure 10 (Comisión de Normalización y Fiscalización de Barreras Comerciales no Arancelarias - INDECOPI, 2012).

Source: Comisión de Normalización y Fiscalización de Barreras Comerciales no Arancelarias - INDECOPI, 2012.

Figure 10 Diagram of a suitable device for concrete flexural testing by the mid-point load method and the application of the double integration method in a simply supported beam.  

During the test, the beam had to be loaded continuously and without impacts. The load must be applied at a constant speed until breakage is reached (Comisión de Normalización y Fiscalización de Barreras Comerciales no Arancelarias -INDECOPI, 2012).

Justification of the investigation

The calculation of the deflections of a beam is carried out according to the theory of elasticity, considering concrete as a linearly elastic material, even though the deflections of the beam are actually due to the nonlinearity of the material, which is the result of external factors such as its composition (cement, aggregates, water), the preparation of the concrete mixture, and the construction of the beam. To date, these conditions cannot be mathematically modeled and are part of the calculation of the theoretical deflection.

Results

This section presents the results of the analysis performed in the laboratory and the correlation between theoretical and real deflection, as shown in Tables 3, 4, and 5. The test was performed for 3 different cure times: 7, 14, and 28 days. The elasticity modulus was calculated, as indicated by the Peruvian building standard E 060 and the inertia of the cross section (Ministerio de Vivienda, Construcción y Saneamiento, 2009). Likewise, with the load resulting from the test, the theoretical deflection was calculated. After reviewing the results of the theoretical and actual deflection, we concluded that there is a very wide difference between the two values. We verify that the theoretical calculations do not reflect the actual deformation of the element, which is due to the nonlinearity of concrete.

Table 3 Results of compressive strength, elasticity modulus at 7, 14 and 28 days of the tested concrete and cross section of the joist (area = 176,7 cm2, joist cross-section = 225 cm2, and length between supports = 45 cm) 

Source: Authors

Table 4 Inertia, length between supports, applied point load, theoretical and real deflection of the simple concrete joist (inertia = 4 218,75 cm4, length between supports = 45 cm) 

Source: Authors

Table 5 Inertia, length between supports, applied point load, theoretical and real deflection of the reinforced concrete beam (inertia = 4 218,75 cm4, length between supports = 45cm) 

Source: Authors

The obtained moment curvature diagram shown in Figure 11 is simplified by using bilinear approximation in the SAP2000 program; the abscissa is multiplied by the plastic length to express it as a function of rotation and reduced only to the part plastic diagram.

Source: Authors

Figure 11 Moment-Curvature diagram for joist section. 

Once the plastic hinge was defined and assigned, a point load was applied which was gradually increased according to the laboratory test until the failure of the section was reached. The values obtained are shown in Tables 4 and 5.

Figure 12 shows the diagram of the theoretical and real deformation of a simple concrete beam per quarry, where non-linear trends are observed between the theoretical and real deformation.

Source: Authors

Figure 12 Diagram of the theoretical and real deformation of the simple concrete joist by quarry.  

The correlation of the theoretical and real deflection of a simple concrete joist is shown in Figure 13, obtaining an Equation (1) of degree 4: y = (-0,33764) x4 + (0,01252) x3 + (-0,71775) x2 + (6,05057) x + 3,91200, which was a good model of adjustment because it had an acceptable coefficient of determination (R2 = 0,9123), because the 99% confidence interval included al the pairs of observed values, and because the result of the analysis of variance indicated that at least one coefficient of the polynomial model is significantly different from zero (p-value = 1,788e-07).

Source: Authors

Figure 13 Correlation of theoretical and real deformation of a simple joist. 

A very good positive correlation was found between the theoretical and actual deformation of a simple concrete beam (R = 0,9551).

According to the Shapiro Wilk test, residues originating from the order 4 polynomial model presented a normal distribution (p-value = 0,3857).

Figure 14 shows the diagram of the theoretical and real deformation of a quarry-reinforced concrete beam, where non-linear trends are observed between the theoretical and real deformation, but these together will give rise to figure 15.

Source: Authors

Figure 14 Diagram of the theoretical and actual deformation of a reinforced concrete joist by quarry.  

Source: Authors

Figure 15 Correlation of theoretical and real deformation of a reinforced concrete joist.  

The correlation of the theoretical and real deflection of the reinforced concrete joist is shown in figure 15, obtaining an Equation (II) of degree 4: y = (-0,0652)x4 + (1,7485) x3 + (1,7920) x2 + (12,7575) x + 7,3383, which was a good model of adjustment, because it had an acceptable coefficient of determination (R2 = 0,9686), because the 99% confidence interval included al the pairs of observed values, and because the result of the analysis of variance indicates that at least one coefficient of the polynomial model is significantly different from zero (p-value = 1,788e-07).

A very good positive correlation was found between the theoretical and actual deformation of the reinforced concrete beam (R = 0,9842).

According to the Shapiro Wilk test, the residuals originating from the order 4 polynomial model were adjusted for the normal distribution (p-value = 0,2811).

Conclusions

Based on the results obtained regarding the correlation of theoretical and practical deflection, we reached the following conclusions:

  1. A very good positive non-linear correlation was found between the theoretical and actual deformation of both the simple and reinforced concrete beams.

  2. The actual deflections for both the simple beam and the reinforced beam are greater than those calculated by the model proposed by Mander et al. (1988).

  3. The evaluated analysis of the experimental results and the parameters calculated using the developed methodology is not within the expected ranges reported by the literature.

  4. For subsequent work, it is recommended to make the stress-strain diagram of the joist to make a more detailed comparison of how it varies and where the divergence between the theoretical and actual deformation lies.

  5. It was also concluded that the days of concrete curing influence the deflection of the joists, obtaining less resistance to deflection during the first weeks.

Acknowledgements

We thank the students of the Resistance of Materials course for the 2020-0 semester of the Professional School of Civil Engineering at the Señor de Siapan University, who collaborated in the experiments and search for information in this research.

References

Alhajri, T., Tahir, M., Azimi, M., Mirza, J., and Ragaee, M. (2016). Behavior of precast U-shaped composite beam integrating cold formed steel with ferro cement slab. Thin Walled Structures, 102, 18-29.10.1016/j.tws.2016.01.014 [ Links ]

Arabnejad Khanouki, M., Ramli Sulong, N., Mahdi Shariati, and Tahir, M. (2016). Investigation of through beam connection to concrete filled circular steel tube (CFCST) column. Journal of Constructional Steel Research, 121, 144-162. 10.1016/j.jcsr.2016.01.002 [ Links ]

Belendez, T., Neipp, C., and Belendez, A. (2002). Estudio de la Flexión de una Viga de Material Elástico no Lineal. Revista Brasileira de Ensino de Física, 24(4). https://www.scielo.br/scielo.php?Links ]

Carrillo, J. and Silva-Páramo, D. (2016). Flexural Tests of Concrete Slabs-on-Ground Reinforced with Steel Fibers. Ingeniería Investigación y Tecnología, 17(3), 317-330. 10.1016/j.riit.2016.07.003 [ Links ]

Carrillo, J., Blandón Valencia, J., and Rubiano, A. (2013). A review of conceptual transparency in US and Colombian seismic design building codes. Ingeniería e Investigación, 33(2), 24-29. 10.15446/ing.investig.v33n2.39506 [ Links ]

Carrillo, J., Cárdenas Pulido, J., and Aperador, W. (2017). Flexural mechanical properties os steel fiber reinforced concrete under corosive environments. Revista Ingeniería de Construcción RIC, 32(2), 59-72. https://www.ricuc.cl/index.php/ric/article/view/582Links ]

Comisión de Normalización y Fiscalización de Barreras Comerciales no Arancelarias - INDECOPI. (2012). Norma Técnica Peruana N.T.P. 339.079 2012. Concreto. Método de Ensayo para determinar la resistencia a la flexión del concreto en vigas simplemente apoyadas con cargas en el centro del tramo, Tercera Edición. Lima, San Borja, Peru: R.0092-2012/CNB - INDECOPI. [ Links ]

Falope, F., Lanzoni, L., and Tarantino, A. (2019). The bending of fully nonlinear beams. Theoretical, numerical and experimental analyses. International Journal of Engineering Science, 145.10.1016/j.ijengsci.2019.103167 [ Links ]

FEMA and ASCE. (2000). Prestandard And Commentary for the seismic rehabilitation of buildings. FEMA 356. https://www.conservationtech.com/FEMA-publications/FEMA356-2000.pdfLinks ]

G. Chiorean, C., and M. Buru, S. (2017). Practical non-linear inelastic analysis method of composite steel concrete beams with partial composite action. Engineering Structures, 134, 74-106. 10.1016/j.engstruct.2016.12.017 [ Links ]

Hamrat, M., Bouziadi, F., Boulekbache, B., Daouadji, H., Chegui, S., Labed, A., and Amziane, S. (2020). Experimental and numerical investigation on the deflaction behavior of precracked and repaired reinforced concrete beams with fiber-reinforced polymer. Construction and Building Materials, 249.10.1016/j.conbuildmat.2020.118745 [ Links ]

Hemn Qader, A., Dishad Kakasor, J., and Abdulkhaleq, Y. (2020). Flexual capacity and behaviour of geopolymer concrete beams reinforced wiht glass fibre reinforced polymer bars. International Journal of Concrete, 14(4), 1-16. 10.1186/s40069-019-0389-1 [ Links ]

Ismail, M., Shariati, M., Abdul Awal, A., Chiong, C., Chahnasir, E., Porbar, A., Heydari, A., and Khorami, M. (2018). Strengthening of bolted shear joints in industrialized ferrocement construction. Steel and Composite Structures, 28(6), 681-690. 10.12989/scs.2018.28.6.681 [ Links ]

Luo, Z., Sinaei, H., Ibrahim, Z., Shariatit, M., Jumaat, Z., Wakil, K., Pham, B. T., Mohamad, E. T., and Khorami, M. (2019). Computational and experimental analysis of beam to column joints reinforced with CFRP plates. Steel and Composite Structures, 30(3), 271-280. 10.12989/scs.2019.30.3.271 [ Links ]

Mander, B., Priestley, M., Park, R., Fellow, and ASCE. (1988). Theoretical Stress-Strain Model for confined concrete. Journal of Structural Engineering, 144(8), 1804-1826. 10.1061/(ASCE)0733-9445(1988)114:8(1804) [ Links ]

Mander, J. (1983). Seismic Design of Bridge Piers. (Doctoral thesis, University of Canterbury, Christchurch, Australia) 10.26021/3134 [ Links ]

Ministerio de Vivienda, Construcción y Saneamiento. (2009). Norma E 060 Concreto Armado - Reglamento Nacional de Edificaciones. Servicio Nacional de Capacitación para la Industria de la Construcción - SENCICO. [ Links ]

Purushothama Raj, P., and Ramasamy, V. (2012). Strength of Materials. Chennai, India: Pearson India. Rodriguez, M., and Restrepo, J. (2012). Práctica y diseño sísmico de edificios en México - cambios necesarios. Revista de Ingeniería Sísmica, 86, 89-118. 10.18867/ris.86.154 [ Links ]

Sahmani, S., and Safaei, B. (2020). Influence of homogenization models on size dependent nonlinear bending and post-buckling of bidirectional functionally graded micro/nano beams. Applied Mathematical Modelling, 82, 336-358. 10.1016/j.apm.2020.01.051 [ Links ]

Sinaei, H., Mohd Zamin, J., and Mahdi , S. (2011). Numerical investigation on exterior reinforced concrete Beam-Column joint strengthened by composite fiber reinforced polymer (CFRP). International Journal of the Physical Sciences, 6(28), 6572-6579,. 10.5897/IJPS11.1225 [ Links ]

How to cite: Muñoz, S., Ruiz Pico, A. A., Anton, J., and Roca, D. (2021). Comparative Study of Theoretical and Real Deflection of Simple and Reinforced Concrete Joists. Ingeniería e Investigación, 41(2), e86 742. 10.15446/ing.investig.v41n2.86 742

Received: April 28, 2020; Accepted: February 12, 2021

Creative Commons License Attribution 4.0 International (CC BY 4.0) Share - Adapt