SciELO - Scientific Electronic Library Online

 
 issue78Colour evolution of the oxide layer formed on the Au-25Fe AND Au-24.5Fe-0.5Co alloysBiomechanical analysis of damaged intervertebral disc using reflective photoelasticity author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Revista Facultad de Ingeniería Universidad de Antioquia

Print version ISSN 0120-6230

Rev.fac.ing.univ. Antioquia  no.78 Medellín Mar. 2016

https://doi.org/10.17533/udea.redin.n78a09 

DOI: 10.17533/udea.redin.n78a09

 

ARTÍCULO ORIGINAL

 

Spectroscopic analysis of coal plasma emission produced by laser ablation

 

Análisis espectroscópico de un plasma de carbón producido por ablación láser

 

 

Liliana Patricia Vera-Londoño, Jaime Andrés Pérez-Taborda*, Henry Riascos-Landázuri

Grupo de investigación Plasma Láser y Aplicaciones, Facultad de Ciencias Básicas, Universidad Tecnológica de Pereira. Carrera 27 #10-02 Barrio Álamos. A. A. 97. Pereira, Colombia.

* Corresponding author: Jaime Andrés Pérez Taborda, e-mail: jaimeandres.perez@csic.es / jaimeandres@ingenieros.com

 

 

(Received December 27, 2013; accepted August 13, 2015)

 

 


ABSTRACT

An analysis of plasma produced by laser ablation using 1,064 nm of laser radiation from a Q-switched Nd:YAG on coal mineral samples under air ambient, was performed. The emission of molecular band systems such as C2 Swan System , the First Negative System N2 (Band head at 501.53 nm) and different emission lines were investigated using the optical emission spectroscopy technique. The C2 molecular spectra (Swan band) were analyzed to determine vibrational temperature (0.62 eV). The density and electron temperature of the plasma have been evaluated using Stark broadening and the intensity of the nitrogen emission lines (N II). Values of 1.2 eV of electron temperature and 1.82×1019 cm-3 of electron density were found.

Keywords: Laser ablation, Laser Induced Plasma Spectroscopy (LIPS), Optical Emission Spectroscopy (EOS), coal


RESUMEN

Se presenta un análisis espectroscópico en aire del plasma producido por la ablación de un láser infrarrojo Nd: YAG con λ= 1.064 nm sobre carbones provenientes de tres diferentes minas naturales (Santander, Norte de Santander y Cesar) en Colombia. El estudio de la emisión de los sistemas de bandas moleculares como Sistema Swan C2, primer Sistema Negativo N2 (alrededor de 501,53 nm) y diferentes líneas de emisión atómicas fueron investigados utilizando la técnica de espectroscopia de emisión óptica. Los espectros moleculares C2 (conocida como banda Swan) se analizaron para determinar la temperatura de vibración (0.62 eV). La temperatura de la densidad de electrones y del plasma han sido evaluadas utilizando el ensanchamiento Stark y la intensidad de las líneas de emisión de nitrógeno (N II). Se encontraron valores de 1,2 eV de temperatura electrónica y 1,82×1019 cm-3 de electrones densidad.

Palabras clave: Ablación Láser, Espectroscopia de plasma inducido por láser, espectroscopía de emisión óptica, carbón


1. Introduction

Laser-produced plasmas are a topic of interest in different fields of science with applications in medicine, astrophysics and synthesis of new materials [1].  In the case of plasmas produced by laser ablation, light energy is used to remove a portion of a sample by melting, fusion, sublimation, ionization, erosion and/or explosion. Several laser ablation-based methods have been implemented such as laser-induced plasma spectroscopy (LIPS), pulsed laser deposition (PLD) [1].  In laser ablation, most of these molecules are formed in their excited states so that spectroscopic measurements offer an excellent mean to investigate their evolution and dynamics [2].

Optical emission spectroscopy (OES) is a technique where light emitted from the plasma by electronically excited species, is collected and transmitted to a grating spectrometer. This technique allows species identification and as a consequence gives information about the elemental composition of the sample. Carbon molecules are very interesting for their unique and fascinating structural and spectroscopic properties. These molecules are very important in astrophysical processes as well as in combustion and soot formation [3].

Research on coals minerals using technologies based in laser [4, 5] is carried on in order to determine their elemental composition. Therefore, plasma diagnostics of coal mineral can provide valuable information about the reaction mechanisms that are involved in combustion and gasification processes [6]. Otherwise, studies of the influence of sample morphology on laser ablation of coal, comparing both temperature and electron density of the coal plasma with the different particle size have been done [7]. Moreover, morphological changes of pulverized coal have been analyzed in [8]. The authors found that volatile components are increasing as a consequence of the temperature and also due to volatilization time.

The experiment carried out with different mineral coals under laser ablation technique and their corresponding plasma diagnostic, is a new approach to study the processes that are present when coal is pulverized by laser.  Besides, the implementation of a cheaper and easier technology for characterization of the plasma radiation-that is due to carbon-laser interaction is the main contribution of this work. Hence, the importance of the OES technique that was used in the experimental work has been demonstrated. Then, Colombian coal samples were ablated to produce plasma at environmental conditions.  The spectra were analyzed to determine both temperature and electron density and also the vibrational temperature.

   

2. Experimental Setup

Laser ablation was done with a Nd: YAG laser (λ=1,064 nm) with a pulse duration of 9 ns and repetition rate of 10 Hz. The laser beam was focused using glass lens with f = 0.23 m on the target and the laser energy fluence was 7 Jcm-2 during 10 min. Experimental targets were coal samples from mines located in Santander, Norte de Santander and Cesar, Colombia. All samples were irradiated in atmospheric air (26 °C and 55% relative humidity). The plume is generated by the laser impact of coal samples as is shown in Figure 1; the detection of plasma emission was performed by means of an optical fiber, which carries the radiation to the spectrometer. The plasma characterization was performed by optical emission spectroscopy (OES) using a spectrometer model Jobin Yvon Triax 550 of 0.55m, f = 6.4 equipped with two gratings of 1200 l/mm and 150 l/mm, coupled to a model 3000 CCD camera cooled air multi-channel and 512×512 pixels. Calibration measurements were done with the fundamental harmonic of laser. Instrumental resolution of equipment is 0.025 nm and the uncertainty values were taken into account for the analysis.

   

3. Results and discussion

Spectral measurements were performed in coal plasma, the electron temperature was evaluated using the relative intensities of the N II, and electron density of plasma with Stark broadening method, and the parameters are available in the literature [10, 11]. Electron temperature determination is shown in Figure 2.

3.1. Temperature and electron density

Spectroscopic measurements of plasmas produced by ionization in air at atmospheric pressure using nanosecond laser pulses are reported.  The measures are consistent with the features observed in nanosecond lasers. The value of electron temperature was 1.2 eV assuming the local thermal equilibrium (LTE) – Eq. (1) [10].

Imn is the intensity of transition line observed. λmn is the wavelength of transition. Amn is the probability of transition.  The degeneracy of upper states is gmn.   Em is the emission of upper level energies.  Boltzmann constant k and Te are the electron temperature. The slope of Eq. (1) [(1) (kTe)-1] is compared with the slope obtained at the graphs and the Te can be calculated.

The Table 1 has the values that were used to determine this temperature.  Experimental values of λ are compared with NIST database values [12].  Amn gmnis taken from NIST data.

LTE is valid if collisional processes are more important than radioactive decay.  In dense plasmas Ne ≥ 1016 cm-3 and temperature kT ≤ 5 eV, the velocity distribution of free electrons is almost always Maxwellian [13].  We estimate the electron density in the plasma by measuring the width of the individual nitrogen line.  The electron density is related to the line broadening, and for highly ionized and high density plasma, the collisions with charged particles present a strong electric field that produced a broadening of the transitions between the split atomic levels.  These micro electric fields are associated with Stark broadening [14].

Electron density must be enough high in order to fulfill the criterion for LTE. This high density is a necessary condition although no sufficient [15]. The relation between electron density and electron temperature is presented in Eq. (2).

Substituting values for Te and ∆E in (2) the value obtained is 9.57×1015 cm-3. The result implies that LTE approximation used in this analysis is valid. An electron density of 1.82×1019 cm-3 using Stark broadening has been calculated. In Figure 3 is shown how the Lorentz function fits the line of the spectra obtained.

3.2. Vibrational temperature

The Swan bands of C2 emission intensities to calculate vibrational temperatures were used.  The strongest band of the well-known Swan system is emitting in the green of the electromagnetic spectrum. This has a special interest since it provides an estimation of the plume temperature and it is very important in fields as astrophysics. These bands have been observed in the emission spectra of comets and also in the absorption spectra of stellar atmospheres [16].  The Swan systems arise from transitions between the electronic states of the C2 molecules.  The band heads ∆ν =0 (Figure 4).  The band emission at 510 nm, 515 nm and 520 nm can be utilized to determine the vibrational temperature.  These emissions correspond to (0,0), (1,1), (2,2) bands [17]. Boltzmann distribution used for calculation is shown in Eq. (3) [10].

λ is the wavelength that corresponds to the emission of headband and I is his corresponding intensity.  c is a constant. G(v')is a expression for the vibrational energy level at the upper electronic state.  Planck constant is ћ, light velocity is c and Boltzmann constant is k.  Finally, Tvib is the vibrational temperature. The emission of nitrogen molecule (Figure 4), which emits in the ultraviolet, visible and infrared electromagnetic ranges, was in this case emitting in the visible range.

The first negative system attributed to that according with literature [18], occurs easily in a plasma at moderate pressure, was observed with band head at 501.53 nm compared with 428.5 nm of band head observed in [18].  Boltzmann distribution values that were used to determine vibrational temperature are presented in Table 2 according with Swan Band of C2 in Figure 4.  The value of Tvibis 0.62 eV (Figure 5) with a high correlation value of 0.99.

   

4. Conclusions

Analysis of coal plasma emission by means of Optical Emission Spectroscopic (OES), the determination of electron temperature, electron density and vibrational temperature and their corresponding ionization states are very interesting research topics.  OES technique is relatively easy to implement and the information that can be obtained with spectroscopy study is very useful to characterize the plasma sample, that in the case of coal mineral can give important information of the performance of coal under plasma ablation. This can provide information about the transition and the excited species, incandescence of the carbon particles, recombination processes and fragmentation.

   

5. References

1. L. Kleiber, H. Fink, R. Niessner and  U. Panne, "Strategies for the analysis of coal by laser ablation inductively coupled plasma mass spectroscopy", Analytical and Bioanalytical Chemistry, vol. 374, no. 1, pp. 109-114, 2002.         [ Links ]

2. S. Harilal, R. Issac, C. Bindhu, V. Nampoori and C. Vallabhan, "Optical emission studies of C2 species in laser-produced plasma from carbon", Journal of Physics D: Applied Physics, vol. 30, no. 12, pp. 1703-1709, 1997.         [ Links ]

3. S. Harilal, R. Issac, C. Bindhu, V. Nampoori and C. Vallabhan, "Emission characteristics and dynamics of C2 from laser produced graphite plasma", J. Appl. Phys., vol. 81, no. 8, pp. 3637-3643, 1997.         [ Links ]

4. C. Romero et al., "Laser-Induced Breakdown Spectroscopy for Coal Characterization and Assessing Slagging Propensity", Energy Fuels, vol. 24, no. 1, pp. 510-517, 2010.         [ Links ]

5. K. Kohse, R. Barlow, M. Aldén and J. Wolfrum, "Combustion at the focus: laser diagnostics and control", Proceedings of the Combustion Institute, vol. 30, no. 1, pp. 89-123, 2005.         [ Links ]

6. J. Qiu et al., "Coal gasification in steam and air medium under plasma conditions: a preliminary study", Fuel Processing Technology, vol. 85, no. 8-10, pp. 969-982, 2004.         [ Links ]

7. H. Riascos, L. Franco and J. Pérez, "Optical spectroscopy of emission from CN plasma formed by laser ablation", Physica Scripta, vol. 131, 2008.         [ Links ]

8. A. Rojas, J. Barraza and R. Barranco, "Cambios morfológicos de carbones pulverizados durante su desvolatilización", Revista Facultad de Ingeniería Universidad de Antioquia, no. 52, pp. 75-87, 2010.         [ Links ]

9. L. Franco, J. Pérez and H. Riascos, "Estudio Espectroscópico de Plasmas del Aire Cobre y Aluminio Producidos por Láser Pulsado", Revista Colombiana de Física, vol. 40, pp. 176-179, 2008.         [ Links ]

10. H. Griem, Plasma Spectroscopy, 1st ed. New York, USA: McGraw-Hill, 1964.         [ Links ]

11. H. Griem, Spectral Line Broadening by Plasmas, 2nd ed.New York, USA: Academic Press, 1974.         [ Links ]

12. National Institute of Standards and Technology (NIST), NIST Atomic Spectra Database Lines Form. [Onilne]. Available: http://physics.nist.gov/PhysRefData/ASD/lines_form.html. Accessed on: Apr. 5, 2012.         [ Links ]

13. H. Griem, "Validity of Local Thermal Equilibrium in Plasma Spectroscopy", Phys. Rev., vol. 131, no. 3, pp. 1170-1176, 1963.         [ Links ]

14. B. Man et al., "Line-broadening analysis of plasma emission produced by laser ablation of metal Cu", Journal of Optics A: Pure and Applied Optics, vol. 6, no. 1, pp. 17-21, 2003.         [ Links ]

15. G. Bekefi, Principles of laser plasmas, 1st ed. New York, USA: Wiley-Interscience, 1976.         [ Links ]

16. J. Hollas, Modern Spectroscopy, 1st ed.New York, USA: John Wiley & Sons, 1992.         [ Links ]

17. R. Pearse and A. Gaydon, The identification of Molecular Spectra, 1st ed. London, England: Chapman and Hall, 1976.         [ Links ]

18. M. Karim, D. Cameron and M. Hashmi, "Plasma diagnostics in the growth of c-BN films", Diamond Rel. Mater., vol. 3, no. 4-6,pp. 551-554, 1994.         [ Links ]