<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0012-7353</journal-id>
<journal-title><![CDATA[DYNA]]></journal-title>
<abbrev-journal-title><![CDATA[Dyna rev.fac.nac.minas]]></abbrev-journal-title>
<issn>0012-7353</issn>
<publisher>
<publisher-name><![CDATA[Universidad Nacional de Colombia]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0012-73532012000300008</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[TÉCNICAS DE INVESTIGACIÓN EN CALIDAD ELÉCTRICA: VENTAJAS E INCONVENIENTES]]></article-title>
<article-title xml:lang="en"><![CDATA[POWER QUALITY RESEARCH TECHNIQUES: ADVANTAGES AND DISADVANTAGES]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[GIL MONTOYA]]></surname>
<given-names><![CDATA[FRANCISCO]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[MANZANO-AGUGLIARO]]></surname>
<given-names><![CDATA[FRANCISCO]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[GÓMEZ LÓPEZ]]></surname>
<given-names><![CDATA[JULIO]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[SÁNCHEZ ALGUACIL]]></surname>
<given-names><![CDATA[PEDRO]]></given-names>
</name>
<xref ref-type="aff" rid="A04"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad de Almería  ]]></institution>
<addr-line><![CDATA[Almería ]]></addr-line>
<country>España</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Universidad de Almería  ]]></institution>
<addr-line><![CDATA[Almería ]]></addr-line>
<country>España</country>
</aff>
<aff id="A03">
<institution><![CDATA[,Universidad de Almería  ]]></institution>
<addr-line><![CDATA[Almería ]]></addr-line>
<country>España</country>
</aff>
<aff id="A04">
<institution><![CDATA[,Universidad de Almería  ]]></institution>
<addr-line><![CDATA[Almería ]]></addr-line>
<country>España</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2012</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2012</year>
</pub-date>
<volume>79</volume>
<numero>173</numero>
<fpage>66</fpage>
<lpage>74</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0012-73532012000300008&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0012-73532012000300008&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0012-73532012000300008&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[La calidad eléctrica juega un papel importantísimo en las redes eléctricas de hoy en día. Por esta razón, es de vital importancia contar con herramientas adecuadas que permitan una eficaz detección de anomalías o perturbaciones en dichos sistemas eléctricos. Frente a las técnicas usadas tradicionalmente, como la transforma de Fourier, hoy en día se están desarrollando nuevos métodos basados en transformadas de dominio, como la Transformada Wavelet o la Transformada S, unido a técnicas basadas en inteligencia artificial como la lógica difusa o las redes neuronales. En este artículo se hace un repaso, a la vez que se discuten estas nuevas técnicas, situándolas en contexto con las técnicas tradicionales y poniendo de manifiesto la superioridad y precisión que se consigue aplicando estos nuevos paradigmas matemáticos. Se detalla, fundamentalmente, la Transformada S y la Wavelet como herramienta de gran proyección y futuro en el análisis de la calidad eléctrica debido a su precisión, inmunidad al ruido e información de calidad que aporta.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Nowadays, power quality (PQ) plays a very important role in power systems. So that is why it is very important to use suitable tools allowing a precise detection of anomalies and perturbations in power systems. Given traditional analysis techniques, such as Fourier Transform, today new tools are being developed based on domain transformation, such as Wavelet Transform (WT) or S-Transform (ST), along with Artificial Intelligence (AI) techniques such as Fuzzy Logic (FL) or Artificial Neural Networks (ANN). In this paper, new algorithm and mathematic techniques are reviewed and discussed, and also compared with traditional techniques, revealing the precision and superiority achieved with these new techniques. ST and WT is detailed, basically, as a tool with great scope and future in power quality analysis because of its precision, noise immunity and its contribution with quality information about PQ.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[calidad eléctrica]]></kwd>
<kwd lng="es"><![CDATA[Transformada S]]></kwd>
<kwd lng="es"><![CDATA[Transformada Wavelet]]></kwd>
<kwd lng="en"><![CDATA[power quality]]></kwd>
<kwd lng="en"><![CDATA[S-Transform]]></kwd>
<kwd lng="en"><![CDATA[Wavelet Transform]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="center"><font size="4" face="Verdana, Arial, Helvetica, sans-serif"><b>T&Eacute;CNICAS DE INVESTIGACI&Oacute;N EN CALIDAD EL&Eacute;CTRICA: VENTAJAS E  INCONVENIENTES</b></font></p>     <p align="center"><i><font size="3"><b><font face="Verdana, Arial, Helvetica, sans-serif">POWER  QUALITY RESEARCH TECHNIQUES: ADVANTAGES AND DISADVANTAGES</font></b></font></i></p>     <p align="center">&nbsp;</p>     <p align="center"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><b>FRANCISCO GIL MONTOYA</b>    <br>   <i>PhD., Profesor Titular de Universidad, Universidad de Almer&iacute;a, Almer&iacute;a, Espa&ntilde;a, <a href="mailto:pagilm@ual.es">pagilm@ual.es</a> </i></font></p>     <p align="center"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><b>FRANCISCO MANZANO-AGUGLIARO</b>    <br>   <i>PhD., Profesor Titular de Universidad, Universidad de Almer&iacute;a, Almer&iacute;a, Espa&ntilde;a, <a href="mailto:fmanzano@ual.es">fmanzano@ual.es</a></i></font></p>     <p align="center"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><b>JULIO G&Oacute;MEZ L&Oacute;PEZ</b>    <br>   <i>PhD., Profesor Asociado, Universidad de Almer&iacute;a, Almer&iacute;a, Espa&ntilde;a, <a href="mailto:jgomez@ual.es">jgomez@ual.es</a></i></font></p>     <p align="center"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><b>PEDRO S&Aacute;NCHEZ ALGUACIL</b>    ]]></body>
<body><![CDATA[<br>   <i>ING., Becario Predoctoral, Universidad de Almer&iacute;a, Almer&iacute;a, Espa&ntilde;a, <a href="mailto:psa603@alboran.ual.es">psa603@alboran.ual.es</a></i></font></p>     <p align="center">&nbsp;</p>     <p align="center"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><b>Recibido para revisar Enero 27 de 2012, aceptado Marzo 5 de 2012, versi&oacute;n final Marzo 8 de 2012</b></font></p>     <p>&nbsp;</p> <hr>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><b>RESUMEN:</b> La calidad el&eacute;ctrica juega un papel important&iacute;simo en las redes el&eacute;ctricas de hoy en d&iacute;a. Por esta raz&oacute;n, es de vital importancia contar con herramientas adecuadas que permitan una eficaz detecci&oacute;n de anomal&iacute;as o perturbaciones en dichos sistemas el&eacute;ctricos. Frente a las t&eacute;cnicas usadas tradicionalmente, como la transforma de Fourier, hoy en d&iacute;a se est&aacute;n desarrollando nuevos m&eacute;todos basados en transformadas de dominio, como la Transformada Wavelet o la Transformada S, unido a t&eacute;cnicas basadas en inteligencia artificial como la l&oacute;gica difusa o las redes neuronales. En este art&iacute;culo se hace un repaso, a la vez que se discuten estas nuevas t&eacute;cnicas, situ&aacute;ndolas en contexto con las t&eacute;cnicas tradicionales y poniendo de manifiesto la superioridad y precisi&oacute;n que se consigue aplicando estos nuevos paradigmas matem&aacute;ticos. Se detalla, fundamentalmente, la Transformada S y la Wavelet como herramienta de gran proyecci&oacute;n y futuro en el an&aacute;lisis de la calidad el&eacute;ctrica debido a su precisi&oacute;n, inmunidad al ruido e informaci&oacute;n de calidad que aporta.</font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><b>PALABRAS CLAVE:</b> calidad el&eacute;ctrica, Transformada S, Transformada Wavelet</font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><b>ABSTRACT:</b> Nowadays, power quality (PQ) plays a very important role in power systems. So that is why it is very important to use suitable tools allowing a precise detection of anomalies and perturbations in power systems. Given traditional analysis techniques, such as Fourier Transform, today new tools are being developed based on domain transformation, such as Wavelet Transform (WT) or S-Transform (ST), along with Artificial Intelligence (AI) techniques such as Fuzzy Logic (FL) or Artificial Neural Networks (ANN). In this paper, new algorithm and mathematic techniques are reviewed and discussed, and also compared with traditional techniques, revealing the precision and superiority achieved with these new techniques. ST and WT is detailed, basically, as a tool with great scope and future in power quality analysis because of its precision, noise immunity and its contribution with quality information about PQ. </font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><b>KEYWORDS:</b> power quality, S-Transform, Wavelet Transform</font></p> <hr>     <p>&nbsp;</p>     <p><font size="3" face="Verdana, Arial, Helvetica, sans-serif"><b>1. INTRODUCCI&Oacute;N</b></font></p>     ]]></body>
<body><![CDATA[<p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">La calidad de la energ&iacute;a que se suministra en las instalaciones el&eacute;ctricas es un concepto que no siempre ha gozado en el pasado de especial relevancia en la ingenier&iacute;a el&eacute;ctrica. Debido a la escasa normativa dedicada a esta tem&aacute;tica, se le ha prestado poca atenci&oacute;n, aunque hoy en d&iacute;a esta situaci&oacute;n est&aacute; cambiando [1-3]. Gracias al auge de la sociedad del conocimiento y su desarrollo, cada vez es m&aacute;s notoria la presencia de equipos el&eacute;ctricos conectados a la red que hacen uso de electr&oacute;nica de potencia para su funcionamiento [4]. Por ejemplo, grandes centros de datos, procesos industriales complejos, sistemas autom&aacute;ticos u ordenadores, no s&oacute;lo en los entornos industriales o empresariales, sino las administraciones gubernamentales o a nivel de los propios usuarios dom&eacute;sticos, se est&aacute;n convirtiendo en elementos cr&iacute;ticos en el desempe&ntilde;o de tareas cotidianas. Esta fuerte dependencia obliga a la red el&eacute;ctrica a realizar un suministro de calidad, en cuanto a valores t&iacute;picos como la tensi&oacute;n, la corriente, o la frecuencia, a fin de garantizar una vida &uacute;til en los dispositivos que sea acorde con las recomendaciones del fabricante, para que no se produzcan da&ntilde;os durante el funcionamiento normal de los mismos. Por otro lado, nuevas fuentes de energ&iacute;a, como las renovables de tipo e&oacute;lico [5] o solar, se est&aacute;n introduciendo cada vez m&aacute;s y suponen una importante fuente de distorsi&oacute;n en la calidad de la energ&iacute;a inyectada. Est&aacute; claramente demostrado que una mala calidad en la tensi&oacute;n de suministro provoca da&ntilde;os y un mal funcionamiento en los aparatos el&eacute;ctricos [6]. La organizaci&oacute;n ITIC (Information Technology Industry Council) tiene publicada una gr&aacute;fica considerada est&aacute;ndar donde se delimita la zona de funcionamiento correcto donde no se producen da&ntilde;os en equipos electr&oacute;nicos (<a href="#fig01">figura 1</a>), aparte habr&aacute; una sin peligro para los mismos y otra zona prohibida donde los equipos pueden sufrir da&ntilde;os de consideraci&oacute;n.</font></p>     <p align="center"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><b><a name="fig01"></a><img src="/img/revistas/dyna/v79n173/a08fig01.gif">    <br>   Figura 1.</b> Curva ITI-CBEMA para caracterizaci&oacute;n de eventos transitorios en la tensi&oacute;n (Adaptada al espa&ntilde;ol)</font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Las compa&ntilde;&iacute;as el&eacute;ctricas son las responsables de garantizar un suministro de calidad [7-9], aunque a veces esto conlleva ciertos conflictos con los propios intereses de dichas compa&ntilde;&iacute;as, y adem&aacute;s la calidad el&eacute;ctrica tambi&eacute;n se puede ver afectada por fen&oacute;menos externos como pueden ser tormentas, o roturas de las l&iacute;neas por accidentes meteorol&oacute;gicos. </font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">La calidad el&eacute;ctrica y sus fen&oacute;menos asociados han sido tratados y descritos en la literatura especializada [10,11], siendo las principales perturbaciones t&iacute;picas en la tensi&oacute;n del suministro de una instalaci&oacute;n el&eacute;ctrica los mostrados en las <a href="#fig02">figuras 2</a> (Impulso transitorio, transitorio oscilante, ruido y muescas) y 3 (Interrupci&oacute;n, sobretensi&oacute;n, hueco de tensi&oacute;n y distorsi&oacute;n arm&oacute;nica).</font></p>     <p align="center"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><b><a name="fig02"></a><img src="/img/revistas/dyna/v79n173/a08fig02.gif">    <br>   Figura 2.</b> T&iacute;picas perturbaciones el&eacute;ctricas en ondas de tensi&oacute;n (I): Impulso transitorio, transitorio oscilante, ruido y muescas</font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Ahora bien, el entendimiento del problema as&iacute; como los planteamientos de resoluci&oacute;n no son sencillos per se, sino que necesitan un alto grado de experiencia y conocimiento en diversos campos de la ingenier&iacute;a y la ciencia en general, como por ejemplo, motores el&eacute;ctricos, sensores, m&aacute;quinas rotativas, transformadores, electr&oacute;nica de potencia, protecciones, an&aacute;lisis de se&ntilde;ales, instrumentos de medida y operaci&oacute;n de sistemas el&eacute;ctricos de potencia. </font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Frente a los tradicionales m&eacute;todos de caracterizar la calidad el&eacute;ctrica, como por ejemplo el c&aacute;lculo del valor eficaz de la onda, hoy en d&iacute;a han surgido numerosas t&eacute;cnicas m&aacute;s avanzadas que permiten diagnosticar dicha calidad con un alto grado de precisi&oacute;n. Estas nuevas herramientas est&aacute;n, fundamentalmente, ligadas al campo de la inteligencia artificial (IA) [12-16]. Entre las t&eacute;cnicas m&aacute;s prometedoras se encuentran los sistemas expertos, la l&oacute;gica difusa, las redes neuronales, los algoritmos evolutivos o las t&eacute;cnicas matem&aacute;ticas basadas en transformaciones de dominio (Transformada Wavelet, Transformada S). El empleo de dichas t&eacute;cnicas permite la detecci&oacute;n de anomal&iacute;as as&iacute; como su clasificaci&oacute;n seg&uacute;n patrones establecidos para la se&ntilde;al el&eacute;ctrica de calidad.</font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Estas t&eacute;cnicas matem&aacute;ticas no s&oacute;lo se est&aacute;n usando en el campo de la calidad el&eacute;ctrica, sino que se usan tanto en otras disciplinas propias la ingenier&iacute;a el&eacute;ctrica como: el diagn&oacute;stico de sistemas, programaci&oacute;n de la generaci&oacute;n, planificaci&oacute;n de sistemas el&eacute;ctricos, an&aacute;lisis de sistemas de potencia, previsi&oacute;n de cargas o diagn&oacute;stico de faltas; como en el campo de las energ&iacute;as renovables [17] o la electr&oacute;nica de potencia [18.19]. El valor a&ntilde;adido que aportan estas nuevas t&eacute;cnicas es de vital importancia, ya que permitir&aacute;n realizar un mejor seguimiento de cualquier instalaci&oacute;n el&eacute;ctrica, consiguiendo una alta tasa de &eacute;xito en el reconocimiento de patrones an&oacute;malos y que, por tanto, permiten un diagn&oacute;stico m&aacute;s eficaz en pos de una actuaci&oacute;n correctiva. </font></p>     ]]></body>
<body><![CDATA[<p>&nbsp;</p>     <p><font size="3" face="Verdana, Arial, Helvetica, sans-serif"><b>2. CALIDAD EL&Eacute;CTRICA</b></font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">La calidad el&eacute;ctrica es un concepto que aparentemente puede resultar sencillo de entender, pero que tiene unas connotaciones bastantes diferentes seg&uacute;n el interlocutor que hace uso de &eacute;l. As&iacute;, una compa&ntilde;&iacute;a el&eacute;ctrica entiende la calidad el&eacute;ctrica desde un punto de vista de fiabilidad de la red y continuidad en el suministro, mientras que un fabricante de equipos el&eacute;ctricos o electr&oacute;nicos puede entenderlo como aquella situaci&oacute;n donde dichos equipos operan correctamente, sin producir errores y sin tener un malfuncionamiento. Finalmente, el usuario final entiende la calidad el&eacute;ctrica como la situaci&oacute;n donde sus procesos u operaciones se desarrollan con normalidad y de manera continua [20-22].</font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Otros autores [23-25] definen desde un punto de vista m&aacute;s t&eacute;cnico la calidad el&eacute;ctrica como aquello que tiene que ver con los problemas manifestados en la tensi&oacute;n, corriente y frecuencia que puedan provocar fallos o aver&iacute;as en los equipos el&eacute;ctricos.</font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">A la hora de analizar el nivel de calidad el&eacute;ctrica en una instalaci&oacute;n determinada, se suelen emplear equipos electr&oacute;nicos port&aacute;tiles de medida digital con capacidades de an&aacute;lisis limitadas. Desde los mult&iacute;metros digitales hasta los analizadores de red profesionales, existe una caracter&iacute;stica com&uacute;n, y es que estos equipos suelen disponer de escasa potencia de c&oacute;mputo, por lo que habitualmente suelen registrar los valores de inter&eacute;s para luego ser analizados (en una segunda etapa) en ordenadores con mucha m&aacute;s potencia de c&aacute;lculo, mejores prestaciones gr&aacute;ficas y, en general, para la presentaci&oacute;n de los resultados de las mediciones realizadas. </font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">En los analizadores de red, las t&eacute;cnicas m&aacute;s usadas se apoyan en la Transformada de Fourier [26, 27] para obtener, por ejemplo, valores relativos a la cantidad y nivel de arm&oacute;nicos presentes en una onda de corriente, y determinar de esta forma, la distorsi&oacute;n provocada a nivel el&eacute;ctrico. Tambi&eacute;n se suelen emplear t&eacute;cnicas matem&aacute;ticas sencillas para la obtenci&oacute;n de valores eficaces o valores de potencia activa, reactiva, aparente, etc. </font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Estas t&eacute;cnicas pueden conducir a resultados incorrectos debido a que est&aacute;n basadas en supuestos que no siempre se cumplen, como pueden ser la consideraci&oacute;n de valores estacionarios, frecuencias invariantes en el tiempo, etc. A d&iacute;a de hoy, estas herramientas han quedado desfasadas frente a otras m&aacute;s modernas y precisas basadas en matem&aacute;ticas m&aacute;s avanzadas como las descritas en Inteligencia Artificial.</font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Con las nuevas t&eacute;cnicas no solamente es posible obtener la informaci&oacute;n de inter&eacute;s que t&iacute;picamente se obten&iacute;a con las t&eacute;cnicas antiguas (por ejemplo, integraci&oacute;n de valores eficaces de ciclo y medio ciclo), l&eacute;ase, tensi&oacute;n eficaz, corriente eficaz, potencia activa/reactiva/aparente, sino que ahora se hace de forma mucho m&aacute;s precisa y adem&aacute;s, se a&ntilde;ade la posibilidad de obtener nueva informaci&oacute;n relativa a eventos extra&ntilde;os o perturbaciones t&iacute;picas como pueden ser las sobretensiones, huecos, microcortes, transitorios, etc., reflejados en las <a href="#fig02">figura 2</a> y <a href="#fig03">3</a>.</font></p>     <p align="center"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><b><a name="fig03"></a><img src="/img/revistas/dyna/v79n173/a08fig03.gif">    <br>   Figura 3.</b> T&iacute;picas perturbaciones el&eacute;ctricas en ondas de tensi&oacute;n (II): Interrupci&oacute;n, sobretensi&oacute;n, hueco de tensi&oacute;n y distorsi&oacute;n arm&oacute;nica</font></p>     ]]></body>
<body><![CDATA[<p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Lo anterior pone de manifiesto las razones que acreditan la relevancia en la investigaci&oacute;n de t&eacute;cnicas, herramientas y m&eacute;todos en calidad el&eacute;ctrica. Ello permite estudiar la problem&aacute;tica asociada a:</font></p> <ul>   <li class="dyna-normal"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">uso extensivo de delicados equipos electr&oacute;nicos basados en microprocesadores y electr&oacute;nica de potencia,</font></li>   <li class="dyna-normal"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">el mal funcionamiento en los equipos el&eacute;ctricos de procesos industriales complejos, </font></li>   <li class="dyna-normal"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">proliferaci&oacute;n de grandes centros de datos y c&oacute;mputo, </font></li>     </ul>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">aspectos legales por la liberalizaci&oacute;n del sector el&eacute;ctrico dando lugar a mayores demandas en la calidad del suministro, etc.</font></p>     <p>&nbsp;</p>     <p><font size="3" face="Verdana, Arial, Helvetica, sans-serif"><b>3. T&Eacute;CNICAS DE AN&Aacute;LISIS Y APLICACI&Oacute;N GENERAL</b></font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">A pesar del tiempo transcurrido desde que la primera instalaci&oacute;n el&eacute;ctrica se puso en marcha, la calidad el&eacute;ctrica ha sido una tarea ardua de valorar desde sus or&iacute;genes. S&oacute;lo gracias a la evoluci&oacute;n de la electr&oacute;nica, all&aacute; por los a&ntilde;os 60-70, y m&aacute;s recientemente con la adopci&oacute;n masiva de dispositivos digitales, ha sido posible afrontar su cuantificaci&oacute;n mediante m&eacute;todos fiables y efectivos. Hasta ese momento, las &uacute;nicas medidas con las que se pod&iacute;a contar eran las proporcionadas por los instrumentos anal&oacute;gicos de origen electro-mec&aacute;nico como amper&iacute;metros, volt&iacute;metros, vat&iacute;metros o contadores tipo Ferraris. Adem&aacute;s, la medida se deb&iacute;a realizar en el justo momento que se produc&iacute;a la perturbaci&oacute;n o anomal&iacute;a, convirtiendo en una labor casi imposible detectar cualquier incidente producido. Gracias a la aparici&oacute;n de los equipos de medida electr&oacute;nicos, y m&aacute;s concretamente, los de tipo digital, el proceso de caracterizaci&oacute;n de la calidad el&eacute;ctrica se fue facilitando en mayor medida. A&uacute;n as&iacute;, la escasa potencia de dichos equipos as&iacute; como las t&eacute;cnicas matem&aacute;ticas empleadas, no han logrado captar con la precisi&oacute;n adecuada ciertos eventos causantes de distorsi&oacute;n en la onda el&eacute;ctrica. Por ejemplo, cambios repentinos en la frecuencia, aparici&oacute;n de perturbaciones de tipo impulsivo o transitorio (v&eacute;ase la <a href="#fig02">figura 2</a>), son imposibles de ser captados si no se emplean t&eacute;cnicas m&aacute;s modernas y avanzadas que las que se vienen usando en la actualidad, siendo el mayor exponente de las mismas la Transformada r&aacute;pida de Fourier o FFT [27, 28].</font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">La FFT se basa en una implementaci&oacute;n algor&iacute;tmica de la Transformada de Fourier</font></p>     <p><img src="/img/revistas/dyna/v79n173/a08eq01.gif"></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">donde f es la frecuencia, t es el tiempo y j es la unidad imaginaria.</font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Pero ha sido en los &uacute;ltimos a&ntilde;os, gracias a la introducci&oacute;n de la Transforma Wavelet [29] y m&aacute;s recientemente la Transformada S [30], cuando se han producido los mayores avances en la detecci&oacute;n de perturbaciones y eventos relacionados con la calidad el&eacute;ctrica. Ahora es posible determinar con gran precisi&oacute;n cuando una onda el&eacute;ctrica de tensi&oacute;n o corriente presenta alguna distorsi&oacute;n que pueda afectar al funcionamiento de los equipos el&eacute;ctricos. </font></p>     ]]></body>
<body><![CDATA[<p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">No s&oacute;lo se es capaz de detectar la perturbaci&oacute;n sino que adem&aacute;s se puede determinar y localizar el momento temporal en el que ocurri&oacute;.</font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">En la <a href="#fig04">figura 4</a> y la <a href="#fig05">figura 5</a> se puede apreciar el resultado de la implementaci&oacute;n de dichas t&eacute;cnicas mediante el software cient&iacute;fico MATLAB. </font></p>     <p align="center"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><b><a name="fig04"></a><img src="/img/revistas/dyna/v79n173/a08fig04.gif">    <br>   Figura 4.</b> Detecci&oacute;n de transitorio impulsivo mediante Transformada Wavelet tipo Morlet. En la parte superior se produce un transitorio de alta frecuencia que es detectado por las sucesivas descomposiciones de detalle de la wavelet</font></p>     <p align="center"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><b><a name="fig05"></a><img src="/img/revistas/dyna/v79n173/a08fig05.gif">    <br>   Figura 5.</b> Detecci&oacute;n de perturbaciones el&eacute;ctricas mediante la Transformada S</font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Una transformaci&oacute;n Wavelet es una transformaci&oacute;n lineal y continua de otra funci&oacute;n dada, expresada como:</font></p>     <p><img src="/img/revistas/dyna/v79n173/a08eq02.gif"></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Existen diferentes funciones madres que se comportan de manera distinta seg&uacute;n el problema a tratar. Por ejemplo, se tiene el wavelet madre tipo Morlet, tipo Sombrero Mejicano o el tipo Daubechies, el cual es muy usado en calidad el&eacute;ctrica ya que proporciona unos buenos resultados frente a las perturbaciones t&iacute;picas de la red.</font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">La Transformada Wavelet permite no s&oacute;lo determinar los instantes temporales donde se producen las perturbaciones sino que adem&aacute;s, tambi&eacute;n proporciona una matriz de coeficientes complejos que a su vez son la base para poder hallar valores caracter&iacute;sticos como puede ser potencia activa, reactiva o aparente [31]. Incluso, gracias a la caracter&iacute;stica inherente de an&aacute;lisis multirresoluci&oacute;n, una de las bondades de este m&eacute;todo es que permite comprimir los datos en bruto provenientes del muestreo de la se&ntilde;al, consiguiendo una almacenamiento m&iacute;nimo de los mismos. Esto supone una gran ventaja ya que uno de los grandes inconvenientes que existe en el tratamiento de la informaci&oacute;n relacionada con calidad el&eacute;ctrica es justamente el alto volumen de datos que se maneja.</font></p>     ]]></body>
<body><![CDATA[<p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Por contra, la Transformada Wavelet presenta una serie de inconvenientes y desventajas como son la complejidad de c&oacute;mputo que a&ntilde;ade al problema, as&iacute; como la intolerancia a ruido en la se&ntilde;al y la dificultad en poder clasificar autom&aacute;ticamente los eventos detectados.</font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Por otro lado la Transformada S, ha abierto nuevas expectativas en el estudio de la calidad el&eacute;ctrica. Proviene de una extensi&oacute;n o combinaci&oacute;n de conceptos asociados a la Transformada Wavelet y a la Transformada de Fourier. De hecho, se deriva de una particularizaci&oacute;n en la funci&oacute;n wavelet madre asociada, concretamente, la utilizaci&oacute;n de una ventana gaussiana como la siguiente:</font></p>     <p><img src="/img/revistas/dyna/v79n173/a08eq03.gif"></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">de forma que la Transformada S queda definida como:</font></p>     <p><img src="/img/revistas/dyna/v79n173/a08eq04.gif"></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">La Transformada S resuelve los inconvenientes que plantea la Transformada Wavelet, ya que es mucho m&aacute;s sencillo realizar una detecci&oacute;n y clasificaci&oacute;n de eventos tal y como se muestra en la <a href="#fig05">figura 5</a>, donde debajo de cada evento de perturbaci&oacute;n de la tensi&oacute;n, se ha representado la imagen que proporciona la Transformada S para el mismo. Adem&aacute;s, preserva la fase absoluta, es mucho m&aacute;s inmune al ruido y su implementaci&oacute;n se basa en una extensi&oacute;n del conocido algoritmo de la transformada r&aacute;pida de Fourier (FFT).</font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Como complemento a las transformadas de dominio, se puede hacer uso de t&eacute;cnicas de clasificaci&oacute;n basadas en l&oacute;gica difusa, redes neuronales o algoritmos evolutivos para crear sistemas expertos y automatizados que clasifiquen los diferentes tipos de perturbaciones y eventos, en la literatura especializada [32] hay numerosos ejemplos y casos de &eacute;xito que muestran como es factible esta combinaci&oacute;n de t&eacute;cnicas con un tasa de acierto cercana al 100% .</font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">En la <a href="#tab01">Tabla 1</a> se resumen las principales ventajas e inconvenientes de las t&eacute;cnicas de an&aacute;lisis. El criterio empleado para la clasificaci&oacute;n ha sido el referido a los principales items de calidad la el&eacute;ctrica estudiados en el presente trabajo.</font></p>     <p align="center"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><b><a name="tab01"></a>Tabla 1.</b> Comparativa de las t&eacute;cnicas de an&aacute;lisis de calidad el&eacute;ctrica m&aacute;s empleadas    <br>   </font><img src="/img/revistas/dyna/v79n173/a08tab01.gif"></p>     ]]></body>
<body><![CDATA[<p>&nbsp;</p>     <p><font size="3" face="Verdana, Arial, Helvetica, sans-serif"><b>4. CONCLUSIONES</b></font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">En el presente trabajo se han descrito los eventos de mayor relevancia que afectan a la calidad el&eacute;ctrica y que pueden ser detectados en las instalaciones el&eacute;ctricas. Adem&aacute;s, se ha realizado una discusi&oacute;n acerca de las &uacute;ltimas t&eacute;cnicas disponibles para el an&aacute;lisis de la calidad el&eacute;ctrica en instalaciones el&eacute;ctricas. Se han expuesto las ventajas que aportan los nuevos m&eacute;todos matem&aacute;ticos relacionados con la inteligencia artificial y las transformadas de dominio. Se puede apreciar como la Transformada S o la Transformada Wavelet permiten hacer una detecci&oacute;n muy precisa de eventos asociados a perturbaciones o transitorios, en contraposici&oacute;n a las t&eacute;cnicas m&aacute;s cl&aacute;sicas, como la FFT, las cuales son mucho m&aacute;s limitadas y no permiten detectar todos los tipos de eventos. </font></p>     <p>&nbsp;</p>     <p><font size="3" face="Verdana, Arial, Helvetica, sans-serif"><b>REFERENCIAS</b></font></p>     <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><b>[1]</b> Key, T.S., Diagnosing Power Quality-Related Computer Problems, Industry Applications, IEEE Transactions on, vol. IA-15, (4), pp. 381-393, 1979.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000078&pid=S0012-7353201200030000800001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[2]</b> Martzloff, F.D. and Gruzs, T.M., Power quality site surveys: facts, fiction, and fallacies, Industry Applications, IEEE Transactions on, vol. 24, (6), pp. 1005-1018, 1988.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000079&pid=S0012-7353201200030000800002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[3]</b> Burke, J.J., Grifith, D.C. and Ward, J., Power quality-two different perspectives, Power Delivery, IEEE Transactions on, vol. 5, (3), pp. 1501-1513, 1990.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000080&pid=S0012-7353201200030000800003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[4]</b> De Velasco, L., El problema de los arm&oacute;nicos en las redes industriales y del sector terciario, DYNA Ingenier&iacute;a e Industria, vol. 79, (6), pp. 55-58, 2004.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000081&pid=S0012-7353201200030000800004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[5]</b> Hern&aacute;ndez-Escobedo, Q., Espinosa-Arenal, F., Salda&ntilde;a-Flores, R., et al. Evaluaci&oacute;n del potencial e&oacute;lico para la generaci&oacute;n de energ&iacute;a el&eacute;ctrica en el estado de Veracruz, M&eacute;xico, Dyna, vol 79, no. 171, pp. 215-221, 2012.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000082&pid=S0012-7353201200030000800005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[6]</b> Baggini, A.B., Handbook of power quality, John Wiley & Sons, Chichester, England, Hoboken, NJ, 2008.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000083&pid=S0012-7353201200030000800006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[7]</b> Cenelec, EN 50160: Voltage characteristics of electricity supplied by public distribution systems, Cenelec, Brüssel, 1999.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000084&pid=S0012-7353201200030000800007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[8]</b> IEC, IEC 61000-4-30: Electromagnetic compatability (EMC). Testing and measurement techniques. Power quality measurement methods, BSI, Brüssel, 2009.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000085&pid=S0012-7353201200030000800008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[9]</b> IEC, IEC 61000-4-7: Electromagnetic compatability (EMC). Testing and measurement techniques - General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto, CEI-IEC, Geneva, 2002.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000086&pid=S0012-7353201200030000800009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[10]</b> IEEE, IEEE Recommended Practice for Monitoring Electric Power Quality, 2009.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000087&pid=S0012-7353201200030000800010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[11]</b> Arseneau, R., Baghzouz, Y. and Belanger, J. et al., Practical definitions for powers in systems with nonsinusoidal waveforms and unbalanced loads: a discussion, Power Delivery, IEEE Transactions on, vol. 11, (1), pp. 79-101, 1996.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000088&pid=S0012-7353201200030000800011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[12]</b> Montoya, F.G., Ba&ntilde;os, R., Gil, C. et al., Minimization of voltage deviation and power losses in power networks using Pareto optimization methods, Engineering Applications of Artificial Intelligence, vol. 23, (5), pp. 695-703, 2010.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000089&pid=S0012-7353201200030000800012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[13]</b> Madan, S. and Bollinger, K.E., Applications of artificial intelligence in power systems, Electric Power Systems Research, vol. 41, (2), pp. 117-131, 1997.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000090&pid=S0012-7353201200030000800013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[14]</b> Chen-Ching, Liu. and Pierce, D., Verification and validation of artificial intelligent systems with applications to power systems, Artificial Intelligence Techniques in Power Systems (Digest No: 1997/354), IEE Colloquium on, pp. 2/1, 1997.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000091&pid=S0012-7353201200030000800014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[15]</b> Rahman, S., Artificial intelligence in electric power systems: a survey of the Japanese industry, Power Systems, IEEE Transactions on, vol. 8, (3), pp. 1211-1218, 1993.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000092&pid=S0012-7353201200030000800015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[16]</b> Zhang, Z.Z., Hope, G.S. and Malik, O.P., Expert systems in electric power systems-a bibliographical survey, Power Systems, IEEE Transactions on, vol. 4, (4), pp. 1355-1362, 1989.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000093&pid=S0012-7353201200030000800016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[17]</b> Ba&ntilde;os, R., Manzano-Agugliaro, F., Montoya, F.G. et al., Optimization methods applied to renewable and sustainable energy: A review, Renewable and Sustainable Energy Reviews, vol. 15, (4), pp. 1753-1766, 2011.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000094&pid=S0012-7353201200030000800017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[18]</b> Vas, P., Artificial-intelligence-based electrical machines and drives : application of fuzzy, neural, fuzzy-neural, and genetic-algorithm-based techniques, Oxford University Press, Oxford ; New York, 1999.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000095&pid=S0012-7353201200030000800018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[19]</b> Bose, B.K., Expert system, fuzzy logic, and neural network applications in power electronics and motion control, Proceedings of the IEEE, vol. 82, no. 8, pp. 1303-1323, 1994.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000096&pid=S0012-7353201200030000800019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[20]</b> Arrillaga, J., Watson, N.R. and Chen, S., Power system quality assessment, Wiley, Chichester, Eng., New York, 2000.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000097&pid=S0012-7353201200030000800020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[21]</b> Greenwood, A., Electrical transients in power systems, 2nd edn, Wiley Interscience, New York, 1991.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000098&pid=S0012-7353201200030000800021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[22]</b> Heydt, G.T., Electric power quality: a tutorial introduction, Computer Applications in Power, IEEE, vol. 11, (1), pp. 15-19, 1998.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000099&pid=S0012-7353201200030000800022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[23]</b> Anis Ibrahim, W.R. and Morcos, M.M., Artificial intelligence and advanced mathematical tools for power quality applications: a survey, Power Delivery, IEEE Transactions on, vol. 17, (2), pp. 668-673, 2002.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000100&pid=S0012-7353201200030000800023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[24]</b> Dugan, R.C., Electrical power systems quality, 2nd edn, McGraw-Hill, New York, 2003.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000101&pid=S0012-7353201200030000800024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[25]</b> Bollen, M., Understanding Power Quality Problems - Voltage Sags and Interruptions, 1999.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000102&pid=S0012-7353201200030000800025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[26]</b> Smith, J.O., Mathematics of the Discrete Fourier Transform (DFT): with Audio Applications, 2nd edn, W3K Publishing, Standford, Calif, 2007.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000103&pid=S0012-7353201200030000800026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[27]</b> Heydt, G.T., Fjeld, P.S., Liu, C.C. et al., Applications of the windowed FFT to electric power quality assessment, Power Delivery, IEEE Transactions on, vol. 14, (4), pp. 1411-1416, 1999.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000104&pid=S0012-7353201200030000800027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[28]</b> Hernandez-Escobedo, Q., Manzano-Agugliaro, F., Gazquez-Parra, J.A. et al., Is the wind a periodical phenomenon? The case of Mexico, Renewable and Sustainable Energy Reviews, vol. 15, (1), pp. 721-728, 2011.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000105&pid=S0012-7353201200030000800028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[29]</b> Santoso, S., Powers, E.J., Grady, W.M. et al., Power quality assessment via wavelet transform analysis, Power Delivery, IEEE Transactions on, vol. 11, (2), pp. 924-930, 1996.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000106&pid=S0012-7353201200030000800029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[30]</b> Stockwell, R.G., Mansinha, L., Lowe, R.P., Localization of the complex spectrum: the S transform, Signal Processing, IEEE Transactions on, vol. 44, (4), pp. 998-1001, 1996.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000107&pid=S0012-7353201200030000800030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[31]</b> Weon-Ki, Y., Devaney, M.J., Reactive power measurement using the wavelet transform, Instrumentation and Measurement, IEEE Transactions on, vol. 49, (2), pp. 246-252, 2000.     &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000108&pid=S0012-7353201200030000800031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><br>   <b>[32]</b> Bollen, M. H. J. and Gu, I.Y.H., Signal processing of power quality disturbances. Wiley-Interscience. New York, 2006. </font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000109&pid=S0012-7353201200030000800032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Key]]></surname>
<given-names><![CDATA[T.S.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Diagnosing Power Quality-Related Computer Problems, Industry Applications]]></article-title>
<source><![CDATA[IEEE Transactions on]]></source>
<year>1979</year>
<volume>IA-15</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>381-393</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Martzloff]]></surname>
<given-names><![CDATA[F.D.]]></given-names>
</name>
<name>
<surname><![CDATA[Gruzs]]></surname>
<given-names><![CDATA[T.M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Power quality site surveys:: facts, fiction, and fallacies, Industry Applications]]></article-title>
<source><![CDATA[IEEE Transactions on]]></source>
<year>1988</year>
<volume>24</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>1005-1018</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Burke]]></surname>
<given-names><![CDATA[J.J.]]></given-names>
</name>
<name>
<surname><![CDATA[Grifith]]></surname>
<given-names><![CDATA[D.C.]]></given-names>
</name>
<name>
<surname><![CDATA[Ward]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Power quality-two different perspectives, Power Delivery]]></article-title>
<source><![CDATA[IEEE Transactions on]]></source>
<year>1990</year>
<volume>5</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>1501-1513</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[De Velasco]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[El problema de los armónicos en las redes industriales y del sector terciario]]></article-title>
<source><![CDATA[DYNA Ingeniería e Industria]]></source>
<year>2004</year>
<volume>79</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>55-58</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hernández-Escobedo]]></surname>
<given-names><![CDATA[Q.]]></given-names>
</name>
<name>
<surname><![CDATA[Espinosa-Arenal]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Saldaña-Flores]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Evaluación del potencial eólico para la generación de energía eléctrica en el estado de Veracruz, México,]]></article-title>
<source><![CDATA[Dyna]]></source>
<year>2012</year>
<volume>79</volume>
<numero>171</numero>
<issue>171</issue>
<page-range>215-221</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Baggini]]></surname>
<given-names><![CDATA[A.B.]]></given-names>
</name>
</person-group>
<source><![CDATA[Handbook of power quality]]></source>
<year>2008</year>
<publisher-loc><![CDATA[Chichester^eNJHoboken NJ]]></publisher-loc>
<publisher-name><![CDATA[John Wiley & Sons]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="book">
<collab>Cenelec</collab>
<source><![CDATA[EN 50160:: Voltage characteristics of electricity supplied by public distribution systems]]></source>
<year>1999</year>
<publisher-loc><![CDATA[Brüssel ]]></publisher-loc>
<publisher-name><![CDATA[Cenelec]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="book">
<collab>IEC</collab>
<source><![CDATA[IEC 61000-4-30:: Electromagnetic compatability (EMC). Testing and measurement techniques. Power quality measurement methods]]></source>
<year>2009</year>
<publisher-loc><![CDATA[Brüssel ]]></publisher-loc>
<publisher-name><![CDATA[BSI]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="book">
<collab>IEC</collab>
<source><![CDATA[IEC 61000-4-7:: Electromagnetic compatability (EMC). Testing and measurement techniques - General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto]]></source>
<year>2002</year>
<publisher-loc><![CDATA[Geneva ]]></publisher-loc>
<publisher-name><![CDATA[CEI-IEC]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="">
<collab>IEEE</collab>
<source><![CDATA[IEEE Recommended Practice for Monitoring Electric Power Quality]]></source>
<year>2009</year>
</nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Arseneau]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Baghzouz]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Belanger]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Practical definitions for powers in systems with nonsinusoidal waveforms and unbalanced loads:: a discussion, Power Delivery]]></article-title>
<source><![CDATA[IEEE Transactions on]]></source>
<year>1996</year>
<volume>11</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>79-101</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Montoya]]></surname>
<given-names><![CDATA[F.G.]]></given-names>
</name>
<name>
<surname><![CDATA[Baños]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Gil]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Minimization of voltage deviation and power losses in power networks using Pareto optimization methods]]></article-title>
<source><![CDATA[Engineering Applications of Artificial Intelligence]]></source>
<year>2010</year>
<volume>23</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>695-703</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Madan]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Bollinger]]></surname>
<given-names><![CDATA[K.E.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Applications of artificial intelligence in power systems]]></article-title>
<source><![CDATA[Electric Power Systems Research]]></source>
<year>1997</year>
<volume>41</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>117-131</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chen-Ching]]></surname>
<given-names><![CDATA[Liu]]></given-names>
</name>
<name>
<surname><![CDATA[Pierce]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Verification and validation of artificial intelligent systems with applications to power systems]]></article-title>
<source><![CDATA[]]></source>
<year>1997</year>
<conf-name><![CDATA[ IEE Colloquium]]></conf-name>
<conf-loc> </conf-loc>
<page-range>2/1</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rahman]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Artificial intelligence in electric power systems:: a survey of the Japanese industry, Power Systems]]></article-title>
<source><![CDATA[IEEE Transactions on]]></source>
<year>1993</year>
<volume>8</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>1211-1218</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[Z.Z.]]></given-names>
</name>
<name>
<surname><![CDATA[Hope]]></surname>
<given-names><![CDATA[G.S.]]></given-names>
</name>
<name>
<surname><![CDATA[Malik]]></surname>
<given-names><![CDATA[O.P.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Expert systems in electric power systems-a bibliographical survey, Power Systems]]></article-title>
<source><![CDATA[IEEE Transactions on]]></source>
<year>1989</year>
<volume>4</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>1355-1362</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Baños]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Manzano-Agugliaro]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Montoya]]></surname>
<given-names><![CDATA[F.G.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Optimization methods applied to renewable and sustainable energy:: A review]]></article-title>
<source><![CDATA[Renewable and Sustainable Energy Reviews]]></source>
<year>2011</year>
<volume>15</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>1753-1766</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vas]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
</person-group>
<source><![CDATA[Artificial-intelligence-based electrical machines and drives :: application of fuzzy, neural, fuzzy-neural, and genetic-algorithm-based techniques]]></source>
<year>1999</year>
<publisher-loc><![CDATA[OxfordNew York ]]></publisher-loc>
<publisher-name><![CDATA[Oxford University Press]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bose]]></surname>
<given-names><![CDATA[B.K.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Expert system, fuzzy logic, and neural network applications in power electronics and motion control]]></article-title>
<source><![CDATA[Proceedings of the IEEE]]></source>
<year>1994</year>
<volume>82</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>1303-1323</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Arrillaga]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Watson]]></surname>
<given-names><![CDATA[N.R.]]></given-names>
</name>
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<source><![CDATA[Power system quality assessment]]></source>
<year>2000</year>
<publisher-loc><![CDATA[WileyChichesterNew York ]]></publisher-loc>
<publisher-name><![CDATA[Eng]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Greenwood]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<source><![CDATA[Electrical transients in power systems]]></source>
<year>1991</year>
<edition>2nd edn</edition>
<publisher-loc><![CDATA[New York ]]></publisher-loc>
<publisher-name><![CDATA[Wiley Interscience]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Heydt]]></surname>
<given-names><![CDATA[G.T.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electric power quality:: a tutorial introduction]]></article-title>
<source><![CDATA[Computer Applications in Power, IEEE]]></source>
<year>1998</year>
<volume>11</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>15-19</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Anis Ibrahim]]></surname>
<given-names><![CDATA[W.R.]]></given-names>
</name>
<name>
<surname><![CDATA[Morcos]]></surname>
<given-names><![CDATA[M.M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Artificial intelligence and advanced mathematical tools for power quality applications:: a survey, Power Delivery]]></article-title>
<source><![CDATA[IEEE Transactions on]]></source>
<year>2002</year>
<volume>17</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>668-673</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dugan]]></surname>
<given-names><![CDATA[R.C.]]></given-names>
</name>
</person-group>
<source><![CDATA[Electrical power systems quality]]></source>
<year>2003</year>
<edition>2nd edn</edition>
<publisher-loc><![CDATA[New York ]]></publisher-loc>
<publisher-name><![CDATA[McGraw-Hill]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bollen]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<source><![CDATA[Understanding Power Quality Problems - Voltage Sags and Interruptions]]></source>
<year>1999</year>
</nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Smith]]></surname>
<given-names><![CDATA[J.O.]]></given-names>
</name>
</person-group>
<source><![CDATA[Mathematics of the Discrete Fourier Transform (DFT):: with Audio Applications]]></source>
<year>2007</year>
<edition>2nd edn</edition>
<publisher-loc><![CDATA[Standford^eCalif Calif]]></publisher-loc>
<publisher-name><![CDATA[W3K Publishing]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Heydt]]></surname>
<given-names><![CDATA[G.T.]]></given-names>
</name>
<name>
<surname><![CDATA[Fjeld]]></surname>
<given-names><![CDATA[P.S.]]></given-names>
</name>
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[C.C.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Applications of the windowed FFT to electric power quality assessment, Power Delivery]]></article-title>
<source><![CDATA[IEEE Transactions on]]></source>
<year>1999</year>
<volume>14</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>1411-1416</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hernandez-Escobedo]]></surname>
<given-names><![CDATA[Q.]]></given-names>
</name>
<name>
<surname><![CDATA[Manzano-Agugliaro]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Gazquez-Parra]]></surname>
<given-names><![CDATA[J.A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Is the wind a periodical phenomenon? The case of Mexico]]></article-title>
<source><![CDATA[Renewable and Sustainable Energy Reviews]]></source>
<year>2011</year>
<volume>15</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>721-728</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Santoso]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Powers]]></surname>
<given-names><![CDATA[E.J.]]></given-names>
</name>
<name>
<surname><![CDATA[Grady]]></surname>
<given-names><![CDATA[W.M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Power quality assessment via wavelet transform analysis, Power Delivery]]></article-title>
<source><![CDATA[IEEE Transactions on]]></source>
<year>1996</year>
<volume>11</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>924-930</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Stockwell]]></surname>
<given-names><![CDATA[R.G.]]></given-names>
</name>
<name>
<surname><![CDATA[Mansinha]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Lowe]]></surname>
<given-names><![CDATA[R.P.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Localization of the complex spectrum:: the S transform, Signal Processing]]></article-title>
<source><![CDATA[IEEE Transactions on]]></source>
<year>1996</year>
<volume>44</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>998-1001</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Weon-Ki]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Devaney]]></surname>
<given-names><![CDATA[M.J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reactive power measurement using the wavelet transform: Instrumentation and Measurement]]></article-title>
<source><![CDATA[IEEE Transactions on]]></source>
<year>2000</year>
<volume>49</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>246-252</page-range></nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bollen]]></surname>
<given-names><![CDATA[M. H. J.]]></given-names>
</name>
<name>
<surname><![CDATA[Gu]]></surname>
<given-names><![CDATA[I.Y.H.]]></given-names>
</name>
</person-group>
<source><![CDATA[Signal processing of power quality disturbances.]]></source>
<year>2006</year>
<publisher-loc><![CDATA[New York ]]></publisher-loc>
<publisher-name><![CDATA[Wiley-Interscience]]></publisher-name>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>
