<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0012-7353</journal-id>
<journal-title><![CDATA[DYNA]]></journal-title>
<abbrev-journal-title><![CDATA[Dyna rev.fac.nac.minas]]></abbrev-journal-title>
<issn>0012-7353</issn>
<publisher>
<publisher-name><![CDATA[Universidad Nacional de Colombia]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0012-73532017000100234</article-id>
<article-id pub-id-type="doi">10.15446/dyna.v84n200.62157</article-id>
<title-group>
<article-title xml:lang="en"><![CDATA[The issue of thermal comfort of medical clothing in the operating room]]></article-title>
<article-title xml:lang="es"><![CDATA[La cuestión de la comodidad térmica de la ropa médica en la sala de operaciones]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Abreu]]></surname>
<given-names><![CDATA[Isabel]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Ribeiro]]></surname>
<given-names><![CDATA[Patrícia]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Abreu]]></surname>
<given-names><![CDATA[Maria José]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,University of Minho Department of Textile Engineering ]]></institution>
<addr-line><![CDATA[Guimarães ]]></addr-line>
<country>Portugal</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>03</month>
<year>2017</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>03</month>
<year>2017</year>
</pub-date>
<volume>84</volume>
<numero>200</numero>
<fpage>234</fpage>
<lpage>239</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0012-73532017000100234&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0012-73532017000100234&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0012-73532017000100234&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract Medical clothes have the primary function of protection. However this function must be correlated with a good comfort experience to the user. The comfort is a very important issue, since professionals are exposed to stress situations that can influence, negatively, their performance work. More specific, thermal comfort plays a crucial role for the best performance of OR medical clothing, involving heat regulation and mass transfer between a clothed body and the environment, once clothing is the interface between body and environment. The aim of this work was to study the behavior of thermal properties of surgical scrub and clean air suits A comparison was made between this two types of clothing using Alambeta equipment, for stationary thermal properties and a Thermal Manikin, to allow the analysis of dynamic thermal properties, such as heat flux and thermal insulation. It was found that clothing thermal insulation is statistically different, showing that the difference between suits may will perceived by the user.]]></p></abstract>
<abstract abstract-type="short" xml:lang="es"><p><![CDATA[Resumen La ropa médica tiene la función principal de protección. Sin embargo, esta función debe estar correlacionada con una buena experiencia de comodidad para el usuario. La comodidad es un tema muy importante, ya que los profesionales están expuestos a situaciones de estrés que pueden influir, negativamente, en su desempeño laboral. Más específico, el confort térmico juega un papel crucial para el mejor rendimiento de la ropa médica usado en la sala de operaciones, que implica la regulación del calor y la transferencia de masa entre un cuerpo vestido y el medio ambiente, una vez que la ropa es la interfaz entre el cuerpo y el medio ambiente. El objetivo de este trabajo fue estudiar el comportamiento de propiedades térmicas de batas quirúrgicos y trajes de aire limpio usados en la sala de operaciones. Se realizó una comparación entre estos dos tipos de prendas con equipos Alambeta, para propiedades térmicas estacionarias y un Maniquí Térmico, para propriedades dinâmicas, como el flujo de calor y el aislamiento térmico. Se encontró que el aislamiento térmico de las prendas es estadísticamente diferente, mostrando que la diferencia entre los trajes puede ser percibida por el usuario.]]></p></abstract>
<kwd-group>
<kwd lng="en"><![CDATA[comfort]]></kwd>
<kwd lng="en"><![CDATA[medical clothing]]></kwd>
<kwd lng="en"><![CDATA[Alambeta]]></kwd>
<kwd lng="en"><![CDATA[Thermal manikin]]></kwd>
<kwd lng="es"><![CDATA[comodidad]]></kwd>
<kwd lng="es"><![CDATA[ropa médica]]></kwd>
<kwd lng="es"><![CDATA[Alambeta]]></kwd>
<kwd lng="es"><![CDATA[maniquí térmico]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Das]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Alagirusamy]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<source><![CDATA[Science in clothing comfort, woodhead publishing]]></source>
<year>2010</year>
</nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Leonas]]></surname>
<given-names><![CDATA[K.K]]></given-names>
</name>
</person-group>
<source><![CDATA[Microorganism protection, in: Textiles for protection, woodhead publishing]]></source>
<year>2005</year>
<page-range>441-64</page-range></nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Council Directive 93/42/EEC of the European Parliament Council of 14 June 1993 concerning medical devices]]></article-title>
<source><![CDATA[Official Journal L 169]]></source>
<year>1993</year>
<volume>12</volume>
<page-range>1</page-range></nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="">
<source><![CDATA[EN 13795:2011+A1:2013, Surgical drapes, gowns and clean air suits, used as medical devices for patients, clinical staff and equipment. General requirements for manufacturers, processors and products, test methods, performance requirements and performance levels]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="">
<source><![CDATA[Council Directive 89/686EEC of the European Parliament Council of 21 December 1989, concerning personal protective equipment]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="book">
<article-title xml:lang=""><![CDATA[Micro-organisms, infection and the role of textiles]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[James]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<source><![CDATA[Textiles for Hygiene and Infection Control]]></source>
<year>2011</year>
<publisher-name><![CDATA[Woodhead Publishing Ltd]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Disposable or reusable clothing in the operating theatre?-The brain prefers reusable!]]></article-title>
<collab>Hohenstein Institute</collab>
<source><![CDATA[Operating Theatre Journal]]></source>
<year>2011</year>
<volume>252</volume>
<page-range>4</page-range></nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="">
<source><![CDATA[2006 - Ergonomics of the thermal environment - Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria]]></source>
<year>2006</year>
</nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vidrago]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Abreu]]></surname>
<given-names><![CDATA[M.J]]></given-names>
</name>
</person-group>
<source><![CDATA[Optimization of the thermal comfort behaviour of bed linen using different softening formulation in Proceedings of the TRS2012]]></source>
<year>2012</year>
<conf-name><![CDATA[ The 41st Textile Research Symposium]]></conf-name>
<conf-date>2012</conf-date>
<conf-loc> </conf-loc>
</nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Differences in comfort perception in relation to local whole body skin wittedness]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fukuzawa]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Havenith]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<source><![CDATA[European Journal of Applied Physiology]]></source>
<year>2009</year>
<volume>106</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>15-24</page-range></nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Local ventilation and wear response of working jackets with different fabric permeability]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ke]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Havenith]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<source><![CDATA[International Journal of Clothing Science and Technology]]></source>
<year>2015</year>
<volume>27</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>835-51</page-range></nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Oliveira]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
</person-group>
<source><![CDATA[Estudo de ambientes térmicos frios: Desenvolvimentos experimentais e avaliação de condições de trabalho]]></source>
<year>2006</year>
<publisher-loc><![CDATA[Portugal ]]></publisher-loc>
<publisher-name><![CDATA[Departamento de Engenharia Mecânica, Faculdade de Ciências e Tecnologia, Universidade de Coimbra]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Measurements of clothing insulation with a thermal manikin operating under the thermal comfort regulation mode. Comparative analysis of the calculation methods]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Oliveira]]></surname>
<given-names><![CDATA[V.]]></given-names>
</name>
<name>
<surname><![CDATA[Gaspar]]></surname>
<given-names><![CDATA[A.R.]]></given-names>
</name>
<name>
<surname><![CDATA[Quintela]]></surname>
<given-names><![CDATA[D.A]]></given-names>
</name>
</person-group>
<source><![CDATA[European Journal of Applied Physiology]]></source>
<year>2008</year>
<volume>104</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>679-88</page-range></nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Abreu]]></surname>
<given-names><![CDATA[I.M]]></given-names>
</name>
<name>
<surname><![CDATA[Ribeiro]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Abreu]]></surname>
<given-names><![CDATA[M.J]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Comparison of different medical clothing used in operating rooms (OR´s) - the importance of thermal comfort at work]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Arezes]]></surname>
</name>
</person-group>
<source><![CDATA[Occupational Safety and Hygiene III]]></source>
<year>2015</year>
<page-range>47</page-range><publisher-loc><![CDATA[London ]]></publisher-loc>
<publisher-name><![CDATA[Taylor & Francis Group]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Thermal comfort properties of cotton and nonwovens surgical gowns with dual functional finish]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cho]]></surname>
<given-names><![CDATA[J.-S.]]></given-names>
</name>
<name>
<surname><![CDATA[Tanabe]]></surname>
<given-names><![CDATA[S.-I.]]></given-names>
</name>
<name>
<surname><![CDATA[Cho]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<source><![CDATA[Applied Human Science]]></source>
<year>1997</year>
<volume>16</volume>
<page-range>87-95</page-range></nlm-citation>
</ref>
<ref id="B16">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Abreu]]></surname>
<given-names><![CDATA[M.J.]]></given-names>
</name>
<name>
<surname><![CDATA[Abreu]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
<name>
<surname><![CDATA[Ribeiro]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<source><![CDATA[Thermo-physiological behavior of single use scrub suits using a thermal manikin]]></source>
<year>2014</year>
<conf-name><![CDATA[ EGEMEDITEX - 2nd International congress on healthcare and medical textiles]]></conf-name>
<conf-date>2014</conf-date>
<conf-loc>Izmir, Turkey </conf-loc>
</nlm-citation>
</ref>
<ref id="B17">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Assessment of man's thermal comfort in practice]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fanger]]></surname>
<given-names><![CDATA[P.O]]></given-names>
</name>
</person-group>
<source><![CDATA[British Journal of Industrial Medicine]]></source>
<year>1973</year>
<volume>30</volume>
<page-range>313-24</page-range></nlm-citation>
</ref>
<ref id="B18">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Objective measurement of heat transport through clothing]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Devanand]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
</person-group>
<source><![CDATA[International Journal of Engineering Research and Development]]></source>
<year>2012</year>
<volume>2</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>43-7</page-range></nlm-citation>
</ref>
<ref id="B19">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Effect of mutual bonding of textile layers on thermal insulation and thermal contact properties of fabric assemblies]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hes]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Lima]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<source><![CDATA[Textile Research Journal]]></source>
<year>1996</year>
<volume>66</volume>
<page-range>245-50</page-range></nlm-citation>
</ref>
<ref id="B20">
<nlm-citation citation-type="">
<source><![CDATA[Ergonomics of the thermal environment - Estimation of thermal insulation and water vapour resistance of a clothing ensemble]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B21">
<nlm-citation citation-type="journal">
<article-title xml:lang=""><![CDATA[Theoretical analysis of three methods for calculating thermal insulation of clothing from thermal manikin]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Huang]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[The Annals of Occupational Hygiene]]></source>
<year>2012</year>
<volume>56</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>728-35</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
