<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0120-2804</journal-id>
<journal-title><![CDATA[Revista Colombiana de Química]]></journal-title>
<abbrev-journal-title><![CDATA[Rev.Colomb.Quim.]]></abbrev-journal-title>
<issn>0120-2804</issn>
<publisher>
<publisher-name><![CDATA[Departamento de Química,  Universidad Nacional de Colombia.]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0120-28042014000100005</article-id>
<article-id pub-id-type="doi">10.15446/rev.colomb.quim.v43n1.50539</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Necesidades metrológicas en los laboratorios clínicos]]></article-title>
<article-title xml:lang="en"><![CDATA[Metrological needs in clinical laboratories]]></article-title>
<article-title xml:lang="pt"><![CDATA[Necessidades metrológicas nos laboratórios clínicos]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Leguizamón]]></surname>
<given-names><![CDATA[John E]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[González]]></surname>
<given-names><![CDATA[Ivonne A]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Bernal]]></surname>
<given-names><![CDATA[Luisa J]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Instituto Nacional de Metrología  ]]></institution>
<addr-line><![CDATA[Bogotá ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Instituto Nacional de Metrología  ]]></institution>
<addr-line><![CDATA[Bogotá ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="A03">
<institution><![CDATA[,Instituto Nacional de Metrología  ]]></institution>
<addr-line><![CDATA[Bogotá ]]></addr-line>
<country>Colombia</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>01</month>
<year>2014</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>01</month>
<year>2014</year>
</pub-date>
<volume>43</volume>
<numero>1</numero>
<fpage>30</fpage>
<lpage>35</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0120-28042014000100005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0120-28042014000100005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0120-28042014000100005&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Los resultados generados por los laboratorios clínicos son elementos claves para el diagnóstico y tratamiento de enfermedades, así como para el seguimiento de los pacientes, por lo tanto se requiere un control metrológico sobre el proceso de medición, el cual determinará el grado de comparabilidad y de confianza requerido sobre los resultados obtenidos. Esta revisión aborda el tema de comparabilidad de las mediciones y de cómo ésta se ve influenciada por factores como la conmutabilidad de los materiales de referencia, los métodos de medición, la disponibilidad de materiales y procedimientos de referencia, además de los intervalos de referencia y límites de decisión para un mensurando en particular. Finalmente se exponen cuáles son los mecanismos adoptados que permitirán garantizar la comparabilidad de las mediciones en esta área.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[The results produced by clinical laboratories are key elements in the diagnosis and treatment of diseases and to monitor patients, so, it requires a metrological control over the measurement process, which will determine the degree of comparability and trust required on the obtained measurement results. Therefore, in this paper we discuss about the comparability of measurements and how it is influenced by factors such as commutability of reference materials, measurement methods, availability of materials and reference procedures, in addition to reference intervals and decision limits for a particular measurand. Finally it is exposed what are the mechanisms that allow ensure measurements comparability on this area.]]></p></abstract>
<abstract abstract-type="short" xml:lang="pt"><p><![CDATA[Os resultados gerados pelos laboratórios clínicos são elementos chaves para o diagnóstico e tratamento de doenças, assim como para o seguimento dos pacientes, sendo preciso um controle metrológico sobre o processo de medição, que determina o grau de comparabilidade e confiança requerido sobre os resultados obtidos. Neste documento trata-se o tópico de comparabilidade das medições e de como a mesma se encontra influenciada por fatores como a comutatividade dos materiais de referência, os métodos de medição, a disponibilidade de materiais e procedimentos de referência, além dos intervalos de referência e limites de decisão para um mensurando em particular. Finalmente, são expostos quais são os mecanismos adotados que permitirão garantir a comparabilidade das medições nesta área.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Metrología]]></kwd>
<kwd lng="es"><![CDATA[Trazabilidad]]></kwd>
<kwd lng="es"><![CDATA[Material de referencia]]></kwd>
<kwd lng="es"><![CDATA[Medición]]></kwd>
<kwd lng="es"><![CDATA[Química clínica]]></kwd>
<kwd lng="en"><![CDATA[Metrology]]></kwd>
<kwd lng="en"><![CDATA[Traceability]]></kwd>
<kwd lng="en"><![CDATA[Reference material]]></kwd>
<kwd lng="en"><![CDATA[Measurement]]></kwd>
<kwd lng="en"><![CDATA[Clinical chemistry]]></kwd>
<kwd lng="pt"><![CDATA[Metrologia]]></kwd>
<kwd lng="pt"><![CDATA[Rastreabilidade]]></kwd>
<kwd lng="pt"><![CDATA[Material de referência]]></kwd>
<kwd lng="pt"><![CDATA[Medição]]></kwd>
<kwd lng="pt"><![CDATA[Química clínica]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  <font face="verdana" size="2">     <p>DOI: <a href="http://dx.doi.org/10.15446/rev.colomb.quim.v43n1.50539" target="_blank">http://dx.doi.org/10.15446/rev.colomb.quim.v43n1.50539</a></p>      <p align="center"><font size="4"><B>Necesidades metrol&oacute;gicas en los laboratorios cl&iacute;nicos</b></font></p>     <p align="center"><font size="3"><B>Metrological needs in clinical laboratories</B></font></p>     <p align="center"><font size="3"><B>Necessidades metrol&oacute;gicas nos laborat&oacute;rios cl&iacute;nicos</B></font></p>     <p><B>John E. Leguizam&oacute;n<sup>1</sup>, Ivonne A. Gonz&aacute;lez<sup>2</sup>, Luisa J. Bernal<sup>3</sup></B></p>     <p><sup>1</sup> Subdirecci&oacute;n de Metrolog&iacute;a Qu&iacute;mica y Biomedicina, Instituto Nacional de Metrolog&iacute;a. Bogot&aacute;, Colombia. Av. Carrera 50 #26-55, interior 2. Tel: 2542222. C&oacute;digo postal: 111321.</p>     <p><sup>2</sup> Subdirecci&oacute;n de Metrolog&iacute;a Qu&iacute;mica y Biomedicina, Instituto Nacional de Metrolog&iacute;a. Bogot&aacute;, Colombia. Av. Carrera 50 #26-55, interior 2. Tel: 2542222. C&oacute;digo postal: 111321.</p>     <p><sup>3</sup> Subdirecci&oacute;n de Metrolog&iacute;a Qu&iacute;mica y Biomedicina, Instituto Nacional de Metrolog&iacute;a. Bogot&aacute;, Colombia. Av. Carrera 50 #26-55, interior 2. Tel: 2542222. C&oacute;digo postal: 111321.</p>     <p><B>Correo electr&oacute;nico de contacto: </B><A href="mailto:jeleguizamon@inm.gov.co">jeleguizamon@inm.gov.co</A></p>     ]]></body>
<body><![CDATA[<p>Recibido: 12 diciembre 2013. Aceptado: 28 enero 2014</p> <hr>     <p><b>Resumen</b></p>     <p>Los resultados generados por los laboratorios cl&iacute;nicos son elementos claves para el diagn&oacute;stico y tratamiento de enfermedades, as&iacute; como para el seguimiento de los pacientes, por lo tanto se requiere un control metrol&oacute;gico sobre el proceso de medici&oacute;n, el cual determinar&aacute; el grado de comparabilidad y de confianza requerido sobre los resultados obtenidos. Esta revisi&oacute;n aborda el tema de comparabilidad de las mediciones y de c&oacute;mo &eacute;sta se ve influenciada por factores como la conmutabilidad de los materiales de referencia, los m&eacute;todos de medici&oacute;n, la disponibilidad de materiales y procedimientos de referencia, adem&aacute;s de los intervalos de referencia y l&iacute;mites de decisi&oacute;n para un mensurando en particular. Finalmente se exponen cu&aacute;les son los mecanismos adoptados que permitir&aacute;n garantizar la comparabilidad de las mediciones en esta &aacute;rea. </p>     <p><B>Palabras clave: </B>Metrolog&iacute;a, Trazabilidad, Material de referencia, Medici&oacute;n, Qu&iacute;mica cl&iacute;nica.</p> <hr>     <p><b>Abstract</b></p>     <p>The results produced by clinical laboratories are key elements in the diagnosis and treatment of diseases and to monitor patients, so, it requires a metrological control over the measurement process, which will determine the degree of comparability and trust required on the obtained measurement results. Therefore, in this paper we discuss about the comparability of measurements and how it is influenced by factors such as commutability of reference materials, measurement methods, availability of materials and reference procedures, in addition to reference intervals and decision limits for a particular measurand. Finally it is exposed what are the mechanisms that allow ensure measurements comparability on this area. </p>     <p><B>Keywords: </B>Metrology, Traceability, Reference material, Measurement, Clinical chemistry.</p> <hr>     <p><b>Resumo</b></p>     <p>Os resultados gerados pelos laborat&oacute;rios cl&iacute;nicos s&atilde;o elementos chaves para o diagn&oacute;stico e tratamento de doen&ccedil;as, assim como para o seguimento dos pacientes, sendo preciso um controle metrol&oacute;gico sobre o processo de medi&ccedil;&atilde;o, que determina o grau de comparabilidade e confian&ccedil;a requerido sobre os resultados obtidos. Neste documento trata-se o t&oacute;pico de comparabilidade das medi&ccedil;&otilde;es e de como a mesma se encontra influenciada por fatores como a comutatividade dos materiais de refer&ecirc;ncia, os m&eacute;todos de medi&ccedil;&atilde;o, a disponibilidade de materiais e procedimentos de refer&ecirc;ncia, al&eacute;m dos intervalos de refer&ecirc;ncia e limites de decis&atilde;o para um mensurando em particular. Finalmente, s&atilde;o expostos quais s&atilde;o os mecanismos adotados que permitir&atilde;o garantir a comparabilidade das medi&ccedil;&otilde;es nesta &aacute;rea. </p>     <p><B>Palavras chave: </B>Metrologia, Rastreabilidade, Material de refer&ecirc;ncia, Medi&ccedil;&atilde;o, Qu&iacute;mica cl&iacute;nica.</p> <hr>     ]]></body>
<body><![CDATA[<p><b><font size="3">Introducci&oacute;n</font></b></p>     <p>La metrolog&iacute;a es la ciencia de las mediciones y sus aplicaciones e incluye todos los aspectos te&oacute;ricos y pr&aacute;cticos del proceso de medici&oacute;n, cualquiera que sea su incertidumbre de medici&oacute;n y su campo de aplicaci&oacute;n (1). Esta ciencia es transversal a todas las ciencias anal&iacute;ticas, entre ellas la qu&iacute;mica cl&iacute;nica, &aacute;rea encargada del estudio de matrices de origen biol&oacute;gico (sangre, orina, l&iacute;quido cefalorraqu&iacute;deo, heces, entre otros) y de sus componentes, a trav&eacute;s de m&eacute;todos qu&iacute;micos o bioqu&iacute;micos, empleando t&eacute;cnicas de an&aacute;lisis convencionales, instrumentales o moleculares. Las mediciones que en esta &aacute;rea se llevan a cabo son de gran impacto en la calidad de vida de las personas, los resultados obtenidos permiten establecer l&iacute;mites de decisi&oacute;n o intervalos de referencia para diagnosticar un paciente, referir un tratamiento m&eacute;dico y tomar decisiones. La necesidad de obtener resultados de medici&oacute;n de varios mensurandos en periodos muy cortos y de aumentar el n&uacute;mero de muestras analizadas ha llevado a que en los &uacute;ltimos a&ntilde;os el grado de automatizaci&oacute;n de los laboratorios cl&iacute;nicos crezca de forma exponencial sin sacrificar la confianza exigida en los resultados de medici&oacute;n que se reportan; para lograrlo los laboratorios deben asegurar el control metrol&oacute;gico de los procesos, de los m&eacute;todos y las t&eacute;cnicas de medici&oacute;n; sin embargo, se han identificado algunas barreras que enfrenta este sector y que se resumen a continuaci&oacute;n. </p>     <p><B>Comparabilidad de los resultados</B></p>     <p>La comparabilidad metrol&oacute;gica de resultados hace alusi&oacute;n a valores o resultados de medida para magnitudes de una naturaleza dada, que son metrol&oacute;gicamente trazables a la misma referencia, sin importar que los valores y sus incertidumbres sean o no del mismo orden de magnitud (1). </p>     <p>El obtener resultados confiables y comparables, es uno de los objetivos m&aacute;s importantes de cualquier laboratorio cl&iacute;nico (2), sin embargo, lo que se observa en varias ocasiones es que, a pesar de analizar la misma sustancia qu&iacute;mica por diferentes m&eacute;todos, el resultado que se obtiene depende del m&eacute;todo de medici&oacute;n y de las referencias que &eacute;ste utilice. Es por esto que no es posible comparar directamente los resultados de las mediciones para obtener intervalos de referencia (3) y l&iacute;mites de decisi&oacute;n comunes &uacute;tiles en el diagn&oacute;stico y tratamiento del paciente (4, 5). </p>     <p>Una forma de alcanzar la comparabilidad de los resultados, despu&eacute;s del uso de materiales de referencia, es emplear metodolog&iacute;as establecidas por convenio internacional (6), Infusino y colaboradores exponen que el objetivo principal de los procedimientos de referencia en el campo cl&iacute;nico es permitir la comparaci&oacute;n entre resultados de muestras humanas, independiente de los procedimientos comerciales, reactivos e instrumentos empleados para el an&aacute;lisis, as&iacute; como de los laboratorios que realizan la determinaci&oacute;n (7). </p>     <p>Junto con materiales de referencia, los procedimientos de referencia, consolidan una herramienta que permite establecer la comparabilidad de las mediciones a nivel global por medio de la trazabilidad, entendida como la propiedad del resultado de una medici&oacute;n, que puede ser relacionada con patrones de mayor jerarqu&iacute;a a trav&eacute;s de una cadena ininterrumpida de calibraciones, todas con una incertidumbre establecida (1). La trazabilidad se da a trav&eacute;s de un sistema de medici&oacute;n de referencia y un sistema de unidades de medici&oacute;n (8) como se muestra en la <a href="#f1">figura 1</a>. </p>     <p align="center"><a name="f1"></a><img src="img/revistas/rcq/v43n1/v43n1a05f1.jpg"></p>     <p>De acuerdo con la <a href="#f1">figura 1</a>, en la cima de la cadena se encuentra la definici&oacute;n de la unidad de medida asociada a una magnitud dada por el Sistema Internacional de Unidades (SI), que a trav&eacute;s de un procedimiento de medici&oacute;n primario establece un material de referencia (MR) primario; este eslab&oacute;n es responsabilidad de los institutos nacionales de metrolog&iacute;a (INM) y organismos internacionales como la Oficina Internacional de Pesas y Medidas (BIPM), la Federaci&oacute;n Internacional de Qu&iacute;mica Cl&iacute;nica y Laboratorio Cl&iacute;nico (IFCC), o la Organizaci&oacute;n Mundial de la Salud (OMS). A partir de estos MR primarios, los laboratorios de referencia (quienes normalmente prestan sus servicios a los fabricantes) desarrollan sus procedimientos de medici&oacute;n, con los cuales generan sus propios MR secundarios, normalmente asociados a un kit de ensayo, para luego ser empleados por los laboratorios de rutina para calibrar sus equipos y desarrollar metodolog&iacute;as (<I>in-house</I>) que les permitan analizar las muestras de los pacientes y cuyos resultados (materiales y m&eacute;todos) son trazables al SI. En la medida que un resultado de medici&oacute;n dependa de varios eslabones en la cadena de trazabilidad, incrementa su incertidumbre, dado que cada calibraci&oacute;n aporta su incertidumbre al resultado final. </p>     <p>Emplear MR trazables al SI y procedimientos de referencia, adem&aacute;s de permitir la comparabilidad de los resultados de medici&oacute;n, resulta clave para establecer la confianza en el resultado de medici&oacute;n a trav&eacute;s del aseguramiento del sistema de medici&oacute;n, compuesto por una sustancia o analito definido inequ&iacute;vocamente, un MR y un procedimiento de medici&oacute;n de referencia (8). </p>     ]]></body>
<body><![CDATA[<p>A pesar de los grandes avances en la automatizaci&oacute;n de los procedimientos de medici&oacute;n en algunos casos, y como barrera t&eacute;cnica, los m&eacute;todos de rutina presentan una selectividad diferente a la del m&eacute;todo de referencia, o los MR empleados por los laboratorios no son trazables al SI, lo que dificulta la comparabilidad de los resultados y la conmutabilidad entre MR (11). </p>     <p><B>Conmutabilidad de los materiales</B></p>     <p>Uno de los principales inconvenientes de las mediciones en el &aacute;rea cl&iacute;nica est&aacute; relacionado con el tipo de matrices que trabaja y la amplia variedad de analitos que estudia, lo que se traduce en que el efecto matriz es uno de los responsables de generar un comportamiento anal&iacute;tico diferente del analito en soluci&oacute;n y del mismo dentro de la matriz de an&aacute;lisis, es decir una falta de conmutabilidad entre los materiales (12). </p>     <p>La conmutabilidad de los materiales de referencia es entendida como la propiedad de un material de referencia expresada por la proximidad, por una parte, entre los resultados de medida obtenidos para una magnitud determinada de este material utilizando dos procedimientos de medida dados, y por otra, entre los resultados de medida para otros materiales especificados (1). Normalmente estos otros materiales corresponden a las muestras de los pacientes. En pocas palabras significa que el MR presente un comportamiento similar al de las muestras de los pacientes bajo los diferentes m&eacute;todos de an&aacute;lisis. Mientras no exista conmutabilidad no es posible establecer la trazabilidad a un sistema de referencia (13, 14). </p>     <p>Adem&aacute;s del efecto matriz, la conmutabilidad de los materiales de referencia depende de las caracter&iacute;sticas de los componentes al ser medidos (12), del procedimiento de purificaci&oacute;n y preparaci&oacute;n de la muestra (15, 16), de las caracter&iacute;sticas espec&iacute;ficas del ensayo y de la t&eacute;cnica anal&iacute;tica usada, entre otras (17, 18).  Un ejemplo de la ausencia de esta propiedad es el caso del an&aacute;lisis de lipasa en suero para el diagn&oacute;stico de pancreatitis, donde se ha evidenciado que el tama&ntilde;o de las micelas del sustrato y la presencia o ausencia de prote&iacute;nas, pueden afectar el resultado de medici&oacute;n (19, 20). </p>     <p>Otro ejemplo es el caso de las determinaciones enzim&aacute;ticas empleadas como herramienta de diagn&oacute;stico y monitoreo de enfermedades relacionadas con &oacute;rganos vitales, Se observa que la actividad catal&iacute;tica depende de la enzima activa presente, de la naturaleza y la concentraci&oacute;n de los sustratos usados, de la presencia de cofactores, el pH, la temperatura, la fuerza i&oacute;nica del medio de reacci&oacute;n, entre otros; en consecuencia el resultado es dependiente del m&eacute;todo de ensayo empleado y es dif&iacute;cil implementar una metodolog&iacute;a est&aacute;ndar que permita, con un mismo procedimiento, evaluar diferentes actividades enzim&aacute;ticas. En estudios realizados por varios investigadores se encontr&oacute; que los resultados obtenidos entre diferentes laboratorios presentan una alta dispersi&oacute;n debido a las diferentes metodolog&iacute;as usadas, las condiciones en que se lleva a cabo el an&aacute;lisis son las responsables de la no conmutabilidad de los MR y comparabilidad de los resultados de medida para este tipo de mediciones (7). Recientemente, varias enzimas han sido purificadas y estabilizadas sin alteraci&oacute;n significativa en sus actividades catal&iacute;ticas, y algunas de ellas han sido certificadas a nivel internacional. Es bien conocido que las propiedades catal&iacute;ticas dependen de la fuente del material, y por lo tanto la conmutabilidad de una enzima de referencia puede depender de la matriz de origen seleccionada y de factores tales como interferentes presentes en la matriz (21, 22) y el procedimiento de purificaci&oacute;n usado (23). </p>     <p>En pro de darle soluci&oacute;n al problema de conmutabilidad y comparabilidad, la IFCC junto con el Instituto para Materiales y M&eacute;todos de Referencia (IMMR) crearon un programa colaborativo cuya misi&oacute;n fue la de establecer sistemas de medici&oacute;n de referencia para las enzimas cl&iacute;nicas de mayor importancia; el programa desarroll&oacute; procedimientos de medici&oacute;n de referencia, materiales de referencia certificados (MRC) y cre&oacute; una red de laboratorios de referencia (23). </p>     <p><B>L&iacute;mites de decisi&oacute;n e intervalos de referencia para el diagn&oacute;stico m&eacute;dico</B></p>     <p>En el esquema (<a href="#f2">figura 2</a>) definido por el Comit&eacute; Nacional de Normas para Laboratorios Cl&iacute;nicos (NCCLS) se muestra c&oacute;mo se establecen los l&iacute;mites de decisi&oacute;n, y por ende, los intervalos de referencia en los laboratorios cl&iacute;nicos (5, 24).</p>     <p align="center"><a name="f2"></a><img src="img/revistas/rcq/v43n1/v43n1a05f2.jpg"></p>     ]]></body>
<body><![CDATA[<p>Para realizar la determinaci&oacute;n en primer lugar es necesario seleccionar, de la poblaci&oacute;n general, unos individuos de referencia que cumplan con unas condiciones o criterios espec&iacute;ficos establecidos seg&uacute;n el estudio, por ejemplo: mujeres embarazadas, fumadores, prescripci&oacute;n de medicamentos, etc., quienes se denominan &ldquo;poblaci&oacute;n o individuos de referencia&rdquo;; de este grupo se selecciona uno m&aacute;s peque&ntilde;o llamado &ldquo;grupo de muestras de referencia&rdquo;, del que se obtienen los resultados del(los) mensurando(s) de inter&eacute;s, por ejemplo colesterol; por &uacute;ltimo, con los valores obtenidos, se grafica la distribuci&oacute;n de los resultados y se definen los l&iacute;mites e intervalos de referencia (5). </p>     <p>En algunas ocasiones la determinaci&oacute;n de los intervalos o l&iacute;mites de referencia puede ser equivocada, ya que se pueden presentar valores at&iacute;picos debidos a registros err&oacute;neos, fallas en los laboratorios, selecci&oacute;n inadecuada de los individuos del grupo de muestras de referencia, entre otros (4). Es importante tener en cuenta que los intervalos de referencia y los l&iacute;mites de decisi&oacute;n no pueden ser generalizados para toda la poblaci&oacute;n debido a que dependen de la edad, sexo, raza, estado de salud (antecedentes de enfermedades), entre otros, relacionados con la muestra seleccionada y el m&eacute;todo de medici&oacute;n empleado (25). </p>     <p>Es habitual que los l&iacute;mites de referencia los establezcan los fabricantes de los kits diagn&oacute;sticos; los laboratorios cl&iacute;nicos, en algunos casos, adoptan toda la informaci&oacute;n suministrada y no realizan una verificaci&oacute;n adecuada antes de usarlos debido, generalmente, a los costos que esto implica. Dentro de los par&aacute;metros que un laboratorio debe evaluar para validar un kit diagn&oacute;stico se encuentran: veracidad, precisi&oacute;n, intervalo din&aacute;mico, sensibilidad y selectividad anal&iacute;tica (26). </p>     <p><B>M&eacute;todos de medici&oacute;n y materiales de referencia en el campo cl&iacute;nico</B></p>     <p><B><I>M&eacute;todos de medici&oacute;n</I></B></p>     <p>Debido a la naturaleza, concentraci&oacute;n, heterogeneidad y diversidad de sustancias o analitos de las muestras cl&iacute;nicas y de sus interacciones, existe un conjunto amplio de t&eacute;cnicas anal&iacute;ticas usadas por los laboratorios cl&iacute;nicos para su an&aacute;lisis. Adem&aacute;s de los m&eacute;todos de an&aacute;lisis instrumental convencional (cromatograf&iacute;a, espectrofotometr&iacute;a, electroforesis, etc.), se observa c&oacute;mo en el &aacute;rea cl&iacute;nica cobran gran importancia los ensayos inmunol&oacute;gicos, que en t&eacute;rminos generales est&aacute;n basados en el grado de interacci&oacute;n entre un ant&iacute;geno y un anticuerpo, con la ventaja de ofrecer una alta selectividad y sensibilidad. </p>     <p>La estandarizaci&oacute;n de los inmunoensayos dentro de un laboratorio no es tan sencilla, ya que no existen m&eacute;todos de referencia que faciliten las comparaciones entre resultados y MR de conmutabilidad demostrada, no es posible asegurar que el calibrador sea qu&iacute;micamente igual a la muestra u homog&eacute;neo debido a la naturaleza proteica de las sustancias o analitos de inter&eacute;s, por lo que la asignaci&oacute;n del valor a partir de un est&aacute;ndar es dif&iacute;cil de realizar (27). Adicionalmente, en algunas ocasiones, para este tipo de ensayos, en la validaci&oacute;n de los m&eacute;todos de medici&oacute;n se emplean t&eacute;cnicas estad&iacute;sticas diferentes a las empleadas en la validaci&oacute;n de m&eacute;todos anal&iacute;ticos qu&iacute;micos convencionales, por ejemplo, en el caso de las enzimas las respuestas de &eacute;stas no presentan comportamientos lineales, por lo que las regresiones planteadas (28) obligan a desarrollos estad&iacute;sticos m&aacute;s complejos respecto a las calibraciones lineales. </p>     <p>En el sector cl&iacute;nico algunas de las sustancias o analitos evaluados se reportan en unidades diferentes a las del SI, generalmente se expresan en Unidades Internacionales (UI), las cuales est&aacute;n basadas en el efecto o actividad biol&oacute;gica del compuesto en cuesti&oacute;n; son establecidas por consenso a trav&eacute;s de un estudio colaborativo internacional coordinado por la OMS a trav&eacute;s del comit&eacute; sobre estandarizaci&oacute;n biol&oacute;gica. Normalmente tienen una equivalencia con una determinada masa del compuesto en relaci&oacute;n con el efecto que produce, dado los continuos avances en las t&eacute;cnicas de purificaci&oacute;n es probable que &eacute;stos valores de masa cambien, por lo que cual no son trazables al SI. Es por esto que la IFCC  recomienda aplicar el SI en qu&iacute;mica cl&iacute;nica cuando sea posible (29), pero autores como Doumas y colaboradores, argumentan  que no es adecuado aplicar una interpretaci&oacute;n muy estricta al SI (30, 31) dado que no siempre es factible hacerlo para esta &aacute;rea de la qu&iacute;mica. </p>     <p>En el caso de las t&eacute;cnicas de medici&oacute;n que involucran &aacute;cidos nucleicos como es el caso de la Reacci&oacute;n en Cadena de la Polimerasa (PCR), la cuantificaci&oacute;n de cantidades relativas de secuencias de &aacute;cido desoxirribonucleico (ADN) permanecen como un proceso anal&iacute;tico complejo supeditado tanto a la calidad de los reactivos, las condiciones de los equipos, pero principalmente a la calidad del ADN o &aacute;cido ribonucleico (ARN) de partida, y esta normalmente es funci&oacute;n del proceso de extracci&oacute;n, de la matriz de an&aacute;lisis, lo que puede generar problemas de conmutabilidad con los MR disponibles. </p>     <p>Normalmente las metodolog&iacute;as disponibles requieren de procesos de extracci&oacute;n, purificaci&oacute;n, detecci&oacute;n y cuantificaci&oacute;n del ADN. Sin embargo, los est&aacute;ndares basados en ADN gen&oacute;mico o amplificaciones por PCR no son lo suficientemente estables, ya que dan como resultado un n&uacute;mero de copias variable. La preparaci&oacute;n de la curva de calibraci&oacute;n al igual que en otros procedimientos anal&iacute;ticos est&aacute; sujeta a errores, con una veracidad dependiente de la calidad del ADN que se emplea como MR y la precisi&oacute;n en la preparaci&oacute;n en la curva de calibraci&oacute;n (32).</p>     ]]></body>
<body><![CDATA[<p>Debido a la diversidad de analitos, as&iacute; como al tipo de mediciones que se llevan a cabo en el &aacute;rea de qu&iacute;mica cl&iacute;nica, los sistemas de medici&oacute;n se pueden clasificar en dos: los que son trazables al SI (analitos libres y familias de analitos) y los que se expresan en UI, no trazables al SI. </p>     <p><B><I>Materiales de Referencia</I></B></p>     <p>El uso apropiado de un MRC es indispensable para asegurar la calidad de la mediciones, disminuir el sesgo y mejorar precisi&oacute;n de los resultados cl&iacute;nicos y de las t&eacute;cnicas anal&iacute;ticas (33, 34). Los MR cl&iacute;nicos con valores conocidos, seg&uacute;n De Bi&eacute;vre (35), son destinados a la validaci&oacute;n de un procedimiento y la verificaci&oacute;n de un instrumento de medici&oacute;n (es decir, para asegurar que se proporciona adecuada, precisa y reproduciblemente la informaci&oacute;n), adem&aacute;s son una herramienta ampliamente usada como control de calidad. Emplear MR en la etapa de validaci&oacute;n, previo al an&aacute;lisis de muestras de rutina, permite evaluar las contribuciones a la incertidumbre de los resultados de medici&oacute;n seg&uacute;n el procedimiento validado (36). </p>     <p>La exactitud global en los resultados de los ensayos cl&iacute;nicos de rutina es atribuida a un mecanismo de dos pasos, en primer lugar a la b&uacute;squeda de la veracidad por medio de la calibraci&oacute;n, y en segundo lugar al aseguramiento de la coherencia de la veracidad a trav&eacute;s del control de calidad. Ambos pasos implican una serie de actividades, de acuerdo con el desarrollo de la t&eacute;cnica de medici&oacute;n espec&iacute;fica, que conectan los resultados con una referencia de mayor orden metrol&oacute;gico, como un MR o un m&eacute;todo de referencia, trazable al SI. La calibraci&oacute;n conlleva directamente al uso de calibradores que cumplen los requisitos de un MR: valores de las propiedades definidos y asignados por un procedimiento metrol&oacute;gicamente v&aacute;lido (37). </p>     <p>Un ejemplo de MR desarrollados para el &aacute;rea cl&iacute;nica son los 13 MRC en concentraci&oacute;n o cantidad de materia de creatinina registrados en la base de datos de la Joint Committee for </p>     <p>Traceability in Laboratory Medicine (JCTLM), estos materiales, seg&uacute;n se reporta, han sido elaborados por INM de pa&iacute;ses como Jap&oacute;n, EEUU y M&eacute;xico en matrices como suero humano, suero bovino o certificados en pureza; tienen como objetivo ser utilizados en la validaci&oacute;n de m&eacute;todos anal&iacute;ticos. Sin embargo, la JCTLM tambi&eacute;n relaciona MR no trazables al SI, sino a protocolos reconocidos internacionalmente, un ejemplo son los factores de coagulaci&oacute;n (38). </p>     <p><B>Mecanismos actuales para asegurar la trazabilidad</B></p>     <p>En Europa en 1998 se gener&oacute; la directiva  EC IVDD 98/79/EC con el objetivo de promover la estandarizaci&oacute;n y armonizaci&oacute;n global para los laboratorios cl&iacute;nicos, aplica para los productores de dispositivos de diagn&oacute;stico in vitro (IVDD); esta directiva establece que los productos empleados como instrumentos o aparatos de diagn&oacute;stico con funci&oacute;n primaria de medici&oacute;n anal&iacute;tica deber&aacute;n dise&ntilde;arse y fabricarse de forma que proporcionen mediciones con una exactitud adecuada, dentro de unos m&aacute;rgenes convenientes de acuerdo con la finalidad prevista del producto, m&eacute;todos de medici&oacute;n y materiales de referencia disponibles. Adicionalmente, esta directiva exige la aplicaci&oacute;n de un sistema de calidad por parte de los fabricantes en el que se documenten los ex&aacute;menes y ensayos que se efect&uacute;an antes, durante y despu&eacute;s de la fabricaci&oacute;n, la frecuencia y el equipo empleado, junto con la calibraci&oacute;n realizada, para la cual se debe garantizar una correlaci&oacute;n apropiada, ente otros requisitos (39). De acuerdo con esto, se observa que se hace necesario establecer una cadena de trazabilidad de los productos empleados en los laboratorios cl&iacute;nicos. Con el cumplimiento de los lineamientos de esta directiva los productores pueden portar en sus productos el sello CE como garant&iacute;a de la calidad del mismo, permiti&eacute;ndoles la comercializaci&oacute;n dentro de la Comunidad Europea. </p>     <p>Con el objetivo de apoyar y soportar la directiva EC IVDD 98/79/EC, a trav&eacute;s de la identificaci&oacute;n de materiales y m&eacute;todos de referencia, en el 2002 se estableci&oacute; una declaraci&oacute;n de cooperaci&oacute;n entre BIPM, IFCC, y la Cooperaci&oacute;n Internacional de Acreditaci&oacute;n de Laboratorios (ILAC), dando origen al  JCTLM, cuya principal funci&oacute;n es la de satisfacer la necesidad de una plataforma internacional que promueva y brinde directivas para el reconocimiento y la aceptaci&oacute;n de equivalencias de las mediciones en laboratorios cl&iacute;nicos, as&iacute; como la trazabilidad a est&aacute;ndares de medici&oacute;n apropiados. Dicha labor se ha venido desarrollando a trav&eacute;s del establecimiento de una base de datos de laboratorios de medici&oacute;n de referencia, MR y procedimientos de medici&oacute;n del m&aacute;s alto orden jer&aacute;rquico, de modo que puedan ser usados por la industria de los IVDD y los usuarios interesados (organizaciones para el aseguramiento de la calidad en el &aacute;rea de los laboratorios cl&iacute;nicos, entidades regulatorias, organizaciones internacionales, institutos nacionales de metrolog&iacute;a e investigadores). </p>     <p>El JCTLM est&aacute; conformado por dos grupos de trabajo: WG1 (por sus siglas en ingl&eacute;s), responsable de identificar procedimientos de medici&oacute;n y MR internacionalmente aceptados, y WG2, encargado de identificar laboratorios de referencia para proveer procedimientos de medici&oacute;n de referencia aceptados internacionalmente para ser usados en la asignaci&oacute;n de valores para MR y la evaluaci&oacute;n de la conmutabilidad (40). </p>     ]]></body>
<body><![CDATA[<p>En cuanto a los MR, el JCTLM hace una clasificaci&oacute;n en dos grupos: tipo A, aquellos compuestos bien caracterizados, disponibles en forma pura y que pueden ser expresados en unidades del SI, y tipo B, donde el mensurando no est&aacute; completamente definido, normalmente hace referencia a mezclas heterog&eacute;neas, expresados en unidades arbitrarias como las UI. </p>     <p>No todos los mensurandos evaluados en los laboratorios cl&iacute;nicos cuentan con un MRC disponible, ya que su naturaleza, las metodolog&iacute;as dise&ntilde;adas, los efectos matriciales asociados, entre otros, no lo permiten. La ISO 17511 (41) establece cinco casos donde expone todas las posibilidades en cuanto a la manera de generar trazabilidad y a su vez una comparabilidad de las mediciones. La  <a href="#t1">Tabla 1</a> describe cada uno de los casos y presenta algunos ejemplos: </p>     <p align="center"><a name="t1"></a><img src="img/revistas/rcq/v43n1/v43n1a05t1.jpg"></p>     <p>El caso 1 se da para los MR tipo A, que corresponden a compuestos qu&iacute;micamente puros, para los que se han desarrollado procedimientos de medici&oacute;n de referencia independientes de los procesos anal&iacute;ticos de rutina. </p>      <p>Los casos 2 a 5, son caracter&iacute;sticos de analitos tipo B, donde los procesos de estandarizaci&oacute;n son m&aacute;s complejos dada su naturaleza heterog&eacute;nea, tanto los MR como los procedimientos de medici&oacute;n, normalmente, se obtienen por consenso entre representantes de las partes interesadas. En el caso 4 se encuentra una limitante adicional, a varios de los MR no se les ha evaluado su conmutabilidad con matrices reales o muestras cl&iacute;nicas o ya se ha demostrado que no son conmutables (42). En el caso 5, donde no existen materiales ni procedimientos de referencia, el mecanismo de trabajo consiste en establecer procesos de medici&oacute;n bajo consenso de tal forma que se logre la armonizaci&oacute;n de los resultados, de esta forma la trazabilidad est&aacute; dada a los procedimientos desarrollados por cada uno de los fabricantes de los IVDD. </p>     <p>De acuerdo con la base de datos de JCTLM, cerca del 20% de los mensurandos son tipo A, y el 80% son tipo B. Dada la importancia de los analitos tipos B en el campo m&eacute;dico, espec&iacute;ficamente en &aacute;reas como oncolog&iacute;a, la necesidad de establecer los mecanismos que conduzcan a la armonizaci&oacute;n de los procedimientos de medici&oacute;n para los casos 4 y 5 es cr&iacute;tica. </p>     <p><font size="3"><b>Conclusiones</b></font></p>     <p>En un esfuerzo por solucionar el problema actual de comparabilidad de resultados, la comunidad cient&iacute;fica del &aacute;rea cl&iacute;nica, busca desarrollar procesos de medici&oacute;n estandarizados y materiales de referencia trazables y de conmutabilidad demostrada, que permitan obtener resultados de medici&oacute;n confiables, facilitando su interpretaci&oacute;n cl&iacute;nica y permitiendo continuidad en el diagn&oacute;stico de un paciente. Uno de los mecanismos encontrados es la implementaci&oacute;n de procedimientos reconocidos internacionalmente que se relacionen con referencias metrol&oacute;gicas aceptadas; en este desarrollo se han identificado varios actores claves: institutos de metrolog&iacute;a, fabricantes de dispositivos de diagn&oacute;stico <I>in vitro</I>, laboratorios cl&iacute;nicos, organizaciones profesionales del &aacute;rea, los organismos de gobierno, universidades y los proveedores de programas de evaluaci&oacute;n externa de la calidad. </p> <hr>     <p><B><font size="3">Referencias</font></b></p>     <!-- ref --><p>1. BIPM. <I>International vocabulary of metrology - Basic and general concepts and associated terms (VIM)</I>.; 2012.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000072&pid=S0120-2804201400010000500001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>2. Panteghini M.; Forest J.C. Standardization in laboratory medicine: new challenges. <I>Clin. Chim. Acta.</I> 2005. <B>355</B>(1-2): 1-12.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000074&pid=S0120-2804201400010000500002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>3. Murat J.B.; Dard C.; Fricker Hidalgo H.; Dard&eacute; M.L.; Brenier-Pinchart M.P.; Pelloux H. Comparison of the Vidas system and two recent fully automated assays for diagnosis and follow-up of toxoplasmosis in pregnant women and newborns. <I>Clin. Vaccine Immunol.</I> 2013. <B>20</B>(8): 1203-1212.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000076&pid=S0120-2804201400010000500003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>4. Horn P.S.; Pesce A.J. Reference intervals: an update. <I>Clin. Chim. Acta</I>. 2003. <B>334</B>(1-2): 5-23.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000078&pid=S0120-2804201400010000500004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>5. Aytekin M.; Emerk K. Accurate reference intervals are required for accurate diagnosis and monitoring of patients. <I>Electron. J. Int. Fed. Clin. Chem. Lab. Med.</I> 2008. <B>19</B>(2): 1-5.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000080&pid=S0120-2804201400010000500005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>6. Dufour D.R.; Lott J.A.; Nolte F.S.; Gretch D.R.; Koff R.S.; Seeff L.B. Diagnosis and monitoring of hepatic injury. I. Performance characteristics of laboratory tests. <I>Clin. Chem.</I> 2000. <B>46</B>(12): 2027-2049.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000082&pid=S0120-2804201400010000500006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>7. Infusino I.; Bonora R.; Panteghini M. Traceability in clinical enzymology. <I>Clin. Biochem. Rev.</I> 2007. <B>28</B>(4): 155-161.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000084&pid=S0120-2804201400010000500007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>8. Thienpont L.M.; Van Uytfanghe K.; De Leenheer A.P. Reference measurement systems in clinical chemistry. <I>Clin. Chim. Acta.</I> 2002. <B>323</B>(1-2): 73-87.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000086&pid=S0120-2804201400010000500008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>9. Siekmann L. Establishing measurement traceability in clinical chemistry. <I>Accredit. Qual. Assur.</I> 2004. <B>9</B>(1-2): 5-17.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000088&pid=S0120-2804201400010000500009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>10. Bock J.L; Eckfeldt J.H. Advances in standardization of laboratory measurement procedures: implications for measuring biomarkers of folate and vitamin B-12 status in NHANES. <I>Am. J. Clin. Nutr.</I> 2011. <B>94</B>(1): 332S-336S.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000090&pid=S0120-2804201400010000500010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>11. F&eacute;rard G.; Edwards J.; Kanno T.; Lessinger J.M.; Moss D.W.; Schiele F.; Tietz N.W.; Vassault A. Interassay calibration as a major contribution to the comparability of results in clinical enzymology. <I>Clin. Biochem.</I> 1998. <B>31</B>(6): 489-494.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000092&pid=S0120-2804201400010000500011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>12. Franzini C.; Ceriotti F. Impact of reference materials on accuracy in clinical chemistry. <I>Clin. Biochem.</I> 1998. <B>31</B>(6): 449-457.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000094&pid=S0120-2804201400010000500012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>13. Ric&oacute;s C.; Juvany R.; Sim&oacute;n M.; Hernandez A.; Alvarez V.; Jimenez C.V.; Minchinela J.; Perich C. Commutability and traceability: their repercussions on analytical bias and inaccuracy. <I>Clin. Chim. Acta.</I> 1999. <B>280</B>(1-2): 135-145.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000096&pid=S0120-2804201400010000500013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>14. Miller W.G. Specimen materials, target values and commutability for external quality assessment (proficiency testing) schemes. <I>Clin. Chim. Acta.</I> 2003. <B>327</B>(1-2): 25-37.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000098&pid=S0120-2804201400010000500014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>15. Panteghini M.; Ceriotti F.; Schumann G.; Siekmann L. Establishing a reference system in clinical enzymology. <I>Clin. Chem. Lab. Med.</I> 2001. <B>39</B>(9): 795-800.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000100&pid=S0120-2804201400010000500015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>16. Vesper H.W.; Miller W.G.; Myers G.L. Reference materials and commutability. <I>Clin. Biochem. Rev.</I> 2007. <B>28</B>(4): 139-147.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000102&pid=S0120-2804201400010000500016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>17. Van Nevel L.; &Ouml;rnemark U.; Smeyers P.; Harper C.; Taylor P.D.P. <I>IMEP-17 Trace and Minor Constituents EUR 20657 EN Report to Participants</I>.; 2003.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000104&pid=S0120-2804201400010000500017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>18. Panteghini M.; Myers G.L.; Miller W.G.; Greenberg N. La importancia de la trazabilidad metrol&oacute;gica en la validez de la medici&oacute;n de creatinina como &iacute;ndice de funci&oacute;n renal. <I>Acta Bioquim. Clin. Latinoam.</I> 2009. <B>43</B>(2): 271-277.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000106&pid=S0120-2804201400010000500018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>19. Lawson N.S.; Williams T.L.; Long T. Matrix effects and accuracy assessment. Identifying matrix-sensitive methods from real-time proficiency testing data. <I>Arch. Pathol. Lab. Med.</I> 1993. <B>117</B>(4): 401-411.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000108&pid=S0120-2804201400010000500019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>20. Eckfeldt J.H.; Copeland K.R. Accuracy verification and identification of matrix effects. The College of American Pathologists' Protocol. <I>Arch. Pathol. Lab. Med.</I> 1993. <B>117</B>(4): 381-386.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000110&pid=S0120-2804201400010000500020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>21. S&aacute;nchez M.; Canalias F.; Palencia T.; Gella F.J. Creatine kinase 2 mass measurement: methods comparison and study of the matrix effect. <I>Clin. Chim. Acta.</I> 1999. <B>288</B>(1-2): 111-119.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000112&pid=S0120-2804201400010000500021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>22. Jackson C.M.; Esnouf M.P.; Winzor D.J.; Duewer D.L. Defining and measuring biological activity: applying the principles of metrology. <I>Accredit. Qual. Assur.</I> 2007. <B>12</B>(6): 283-294.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000114&pid=S0120-2804201400010000500022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>23. F&eacute;rard G.; Lessinger J.M. Preparation of enzyme calibration materials. <I>Clin. Chim. Acta.</I> 1998. <B>278</B>(2): 151-162.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000116&pid=S0120-2804201400010000500023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>24. <I>National Committee for Clinical Laboratory Standards - </I>NCCLS. <I>C28-A2: How to Define and Determine Reference Intervals in the Clinical Laboratory; Approved Guideline</I>. Second. 2000: 172.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000118&pid=S0120-2804201400010000500024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>25. Schnabl K.; Khun M.; Adeli K. Pediatric reference intervals: critical gap analysis and establishment of a national initiative. <I>Electron. J. Int. Fed. Clin. Chem. Lab. Med.</I> 2008. <B>19</B>(2): 1 - 8.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000120&pid=S0120-2804201400010000500025&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>26. Horowitz G.L. Reference intervals: Practical aspects. <I>Electron. J. Int. Fed. Clin. Chem. Lab. Med.</I> 2008. <B>19</B>(2): 1-11.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000122&pid=S0120-2804201400010000500026&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>27. Stenman U.H. Immunoassay Standardization: Is It Possible , Who Is Responsible , Who Is Capable? <I>Clin. Chem.</I> 2001. <B>47</B>(5): 815-820.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000124&pid=S0120-2804201400010000500027&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>28. Miller J.N.; Miller J.C. <I>Estadistica y quimiometria para quimica analitica</I>. 4a ed. Madrid: Pearson Educacion S.A. 2002: pp. 296.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000126&pid=S0120-2804201400010000500028&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>29. IUPAC IU of P and AC, Chemistry, IFCC IF of C. Expert panel on quantities and units in clinical chemistry (recommendations 1979). <I>Pure Appl. Chem. Chem.</I> 1979. <b>1</b>: 2451-2479.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000128&pid=S0120-2804201400010000500029&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>30. Rigg J.C.; Brown S.S.; Dybkaer R.; Olsen H. <I>Compendio de terminolog&iacute;a y nomenclatura de propiedades en las ciencias de laboratorio cl&iacute;nico</I>. IUPAC, Union Internacional de Quimica Pura y Aplicada, e IFCC, Federacion Internacional de Quimica Clinica; 1993: pp. 125.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000130&pid=S0120-2804201400010000500030&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>31. Doumas B.T.; Laessig R.H.; Larson F.C. The sanitized Syst&egrave;me International (SI) d'Unit&eacute;s. Opinion. <I>Clin. Chim. Acta</I>. 1987. <B>167</B>: 113 - 116.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000132&pid=S0120-2804201400010000500031&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>32. Rutledge R.G.; C&ocirc;t&eacute; C. Mathematics of quantitative kinetic PCR and the application of standard curves. <I>Nucleic Acids Res.</I> 2003. <B>31</B>(16): e93.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000134&pid=S0120-2804201400010000500032&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>33. Davies K.W.; Park H. Quality assurance in clinical chemistry laboratories in the UK. <I>Accredit. Qual. Assur.</I> 1999. <B>4</B>: 18-26.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000136&pid=S0120-2804201400010000500033&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>34. Ib&aacute;&ntilde;ez C.; L&oacute;pez J.F.; Sahuquillo A. Certified reference materials for analytical mercury speciation in biological and environmental matrices: do they meet user needs?; a review. <I>Anal. Chim. Acta</I>. 2012. <B>720</B>: 9-15.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000138&pid=S0120-2804201400010000500034&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>35. De Bi&eacute;vre P.; Dybkaer R.; Fajgelj A.; Hibbert D.B. Metrological traceability of measurement results in chemistry: Concepts and implementation ( IUPAC Technical Report )*. 2011. <B>83</B>(10): 1873-1935.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000140&pid=S0120-2804201400010000500035&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>36. Buzoianu M.; Aboul-Enein H.Y. Clinical reference materials for the validation of the performance of photometric systems used for clinical analyses. <I>Accredit. Qual. Assur.</I> 1997. <B>2</B>(8): 375-380.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000142&pid=S0120-2804201400010000500036&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>37. International Organization for Standardization. ISO Guide 35:2006 Reference materials - General and statistical principles for certification. 2006: 72.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000144&pid=S0120-2804201400010000500037&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>38. JCTLM Laboratory medicine and vin vitro diagnostics. <I>List of all available certified reference materials</I>. 2013: 1-76.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000146&pid=S0120-2804201400010000500038&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>39. Parlamento Europeo y del Consejo. Directiva 98/79/CE. 1998. (6): 37.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000148&pid=S0120-2804201400010000500039&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>     <!-- ref --><p>40. BIPM - Bureau International des Poids et Mesures. BIPM. Disponible en: <a href="http://www.bipm.org/" target="_blank">http://www.bipm.org/</a>. &#91;Consultado el 17 de Febrero de 2014&#93;    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000150&pid=S0120-2804201400010000500040&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref -->. </p>     <!-- ref --><p>41. International Organization for Standardization. ISO 17511:2003 In diagnostic medical devices - Measurement of quantities in biological samples - Metrological traceability of values assigned to calibrators and control materials. 2003: 23 &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000152&pid=S0120-2804201400010000500041&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>42. Greg Miller W.; Myers G.L.; Lou Gantzer M.; Kahn S.E.; Sch&ouml;nbrunner E.R.; Thienpont L.M.; Bunk D.M.; Christenson R.H.; Eckfeldt J.H.; Lo S.F.; N&uuml;bling C.M.; Sturgeon C.M. Roadmap for harmonization of clinical laboratory measurement procedures. <I>Clin. Chem.</I> 2011. <B>57</B>(8): 1108-1117.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000153&pid=S0120-2804201400010000500042&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> </p>  </font>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="">
<collab>BIPM</collab>
<source><![CDATA[International vocabulary of metrology - Basic and general concepts and associated terms (VIM)]]></source>
<year>2012</year>
</nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Panteghini]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Forest]]></surname>
<given-names><![CDATA[J.C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Standardization in laboratory medicine: new challenges]]></article-title>
<source><![CDATA[Clin. Chim. Acta]]></source>
<year>2005</year>
<volume>355</volume>
<numero>1-2</numero>
<issue>1-2</issue>
<page-range>1-12</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Murat]]></surname>
<given-names><![CDATA[J.B]]></given-names>
</name>
<name>
<surname><![CDATA[Dard]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Fricker Hidalgo]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Dardé]]></surname>
<given-names><![CDATA[M.L]]></given-names>
</name>
<name>
<surname><![CDATA[Brenier-Pinchart]]></surname>
<given-names><![CDATA[M.P]]></given-names>
</name>
<name>
<surname><![CDATA[Pelloux]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of the Vidas system and two recent fully automated assays for diagnosis and follow-up of toxoplasmosis in pregnant women and newborns]]></article-title>
<source><![CDATA[Clin. Vaccine Immunol]]></source>
<year>2013</year>
<volume>20</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>1203-1212</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Horn]]></surname>
<given-names><![CDATA[P.S]]></given-names>
</name>
<name>
<surname><![CDATA[Pesce]]></surname>
<given-names><![CDATA[A.J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reference intervals: an update]]></article-title>
<source><![CDATA[Clin. Chim. Acta]]></source>
<year>2003</year>
<volume>334</volume>
<numero>1-2</numero>
<issue>1-2</issue>
<page-range>5-23</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Aytekin]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Emerk]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Accurate reference intervals are required for accurate diagnosis and monitoring of patients]]></article-title>
<source><![CDATA[Electron. J. Int. Fed. Clin. Chem. Lab. Med]]></source>
<year>2008</year>
<volume>19</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>1-5</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dufour]]></surname>
<given-names><![CDATA[D.R]]></given-names>
</name>
<name>
<surname><![CDATA[Lott]]></surname>
<given-names><![CDATA[J.A]]></given-names>
</name>
<name>
<surname><![CDATA[Nolte]]></surname>
<given-names><![CDATA[F.S]]></given-names>
</name>
<name>
<surname><![CDATA[Gretch]]></surname>
<given-names><![CDATA[D.R]]></given-names>
</name>
<name>
<surname><![CDATA[Koff]]></surname>
<given-names><![CDATA[R.S]]></given-names>
</name>
<name>
<surname><![CDATA[Seeff]]></surname>
<given-names><![CDATA[L.B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Diagnosis and monitoring of hepatic injury. I. Performance characteristics of laboratory tests]]></article-title>
<source><![CDATA[Clin. Chem]]></source>
<year>2000</year>
<volume>46</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>2027-2049</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Infusino]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Bonora]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Panteghini]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Traceability in clinical enzymology]]></article-title>
<source><![CDATA[Clin. Biochem. Rev]]></source>
<year></year>
<volume>28</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>155-161</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Thienpont]]></surname>
<given-names><![CDATA[L.M]]></given-names>
</name>
<name>
<surname><![CDATA[Van Uytfanghe]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[De Leenheer]]></surname>
<given-names><![CDATA[A.P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reference measurement systems in clinical chemistry]]></article-title>
<source><![CDATA[Clin. Chim. Acta]]></source>
<year>2002</year>
<volume>323</volume>
<numero>1-2</numero>
<issue>1-2</issue>
<page-range>73-87</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Siekmann]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Establishing measurement traceability in clinical chemistry]]></article-title>
<source><![CDATA[Accredit. Qual. Assur]]></source>
<year>2004</year>
<volume>9</volume>
<page-range>1-2</page-range><page-range>5-17</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bock]]></surname>
<given-names><![CDATA[J.L]]></given-names>
</name>
<name>
<surname><![CDATA[Eckfeldt]]></surname>
<given-names><![CDATA[J.H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Advances in standardization of laboratory measurement procedures: implications for measuring biomarkers of folate and vitamin B-12 status in NHANES]]></article-title>
<source><![CDATA[Am. J. Clin. Nutr]]></source>
<year>2011</year>
<volume>94</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>332S-336S</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Férard]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Edwards]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Kanno]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Lessinger]]></surname>
<given-names><![CDATA[J.M]]></given-names>
</name>
<name>
<surname><![CDATA[Moss]]></surname>
<given-names><![CDATA[D.W]]></given-names>
</name>
<name>
<surname><![CDATA[Schiele]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Tietz]]></surname>
<given-names><![CDATA[N.W]]></given-names>
</name>
<name>
<surname><![CDATA[Vassault]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Interassay calibration as a major contribution to the comparability of results in clinical enzymology]]></article-title>
<source><![CDATA[Clin. Biochem]]></source>
<year>1998</year>
<volume>31</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>489-494</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Franzini]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Ceriotti]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Impact of reference materials on accuracy in clinical chemistry]]></article-title>
<source><![CDATA[Clin. Biochem]]></source>
<year>1998</year>
<volume>31</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>449-457</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ricós]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Juvany]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Simón]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Hernandez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Alvarez]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Jimenez]]></surname>
<given-names><![CDATA[C.V]]></given-names>
</name>
<name>
<surname><![CDATA[Minchinela]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Perich]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Commutability and traceability: their repercussions on analytical bias and inaccuracy]]></article-title>
<source><![CDATA[Clin. Chim. Acta]]></source>
<year>1999</year>
<volume>280</volume>
<numero>1-2</numero>
<issue>1-2</issue>
<page-range>135-145</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Miller]]></surname>
<given-names><![CDATA[W.G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Specimen materials, target values and commutability for external quality assessment (proficiency testing) schemes]]></article-title>
<source><![CDATA[Clin. Chim. Acta]]></source>
<year>2003</year>
<volume>327</volume>
<numero>1-2</numero>
<issue>1-2</issue>
<page-range>25-37</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Panteghini]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Ceriotti]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Schumann]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Siekmann]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Establishing a reference system in clinical enzymology]]></article-title>
<source><![CDATA[Clin. Chem. Lab. Med]]></source>
<year>2001</year>
<volume>39</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>795-800</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vesper]]></surname>
<given-names><![CDATA[H.W]]></given-names>
</name>
<name>
<surname><![CDATA[Miller]]></surname>
<given-names><![CDATA[W.G]]></given-names>
</name>
<name>
<surname><![CDATA[Myers]]></surname>
<given-names><![CDATA[G.L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reference materials and commutability]]></article-title>
<source><![CDATA[Clin. Biochem. Rev]]></source>
<year>2007</year>
<volume>28</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>139-147</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Van Nevel]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Örnemark]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Smeyers]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Harper]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Taylor]]></surname>
<given-names><![CDATA[P.D.P]]></given-names>
</name>
</person-group>
<source><![CDATA[IMEP-17 Trace and Minor Constituents EUR 20657 EN Report to Participants]]></source>
<year>2003</year>
</nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Panteghini]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Myers]]></surname>
<given-names><![CDATA[G.L]]></given-names>
</name>
<name>
<surname><![CDATA[Miller]]></surname>
<given-names><![CDATA[W.G]]></given-names>
</name>
<name>
<surname><![CDATA[Greenberg]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[La importancia de la trazabilidad metrológica en la validez de la medición de creatinina como índice de función renal]]></article-title>
<source><![CDATA[Acta Bioquim. Clin. Latinoam]]></source>
<year>2009</year>
<volume>43</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>271-277</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lawson]]></surname>
<given-names><![CDATA[N.S]]></given-names>
</name>
<name>
<surname><![CDATA[Williams]]></surname>
<given-names><![CDATA[T.L]]></given-names>
</name>
<name>
<surname><![CDATA[Long]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Matrix effects and accuracy assessment. Identifying matrix-sensitive methods from real-time proficiency testing data]]></article-title>
<source><![CDATA[Arch. Pathol. Lab. Med]]></source>
<year>1993</year>
<volume>117</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>401-411</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Eckfeldt]]></surname>
<given-names><![CDATA[J.H]]></given-names>
</name>
<name>
<surname><![CDATA[Copeland]]></surname>
<given-names><![CDATA[K.R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Accuracy verification and identification of matrix effects. The College of American Pathologists' Protocol]]></article-title>
<source><![CDATA[Arch. Pathol. Lab. Med]]></source>
<year>1993</year>
<volume>117</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>381-386</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sánchez]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Canalias]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Palencia]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Gella]]></surname>
<given-names><![CDATA[F.J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Creatine kinase 2 mass measurement: methods comparison and study of the matrix effect]]></article-title>
<source><![CDATA[Clin. Chim. Acta]]></source>
<year>1999</year>
<volume>288</volume>
<numero>1-2</numero>
<issue>1-2</issue>
<page-range>111-119</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jackson]]></surname>
<given-names><![CDATA[C.M]]></given-names>
</name>
<name>
<surname><![CDATA[Esnouf]]></surname>
<given-names><![CDATA[M.P]]></given-names>
</name>
<name>
<surname><![CDATA[Winzor]]></surname>
<given-names><![CDATA[D.J]]></given-names>
</name>
<name>
<surname><![CDATA[Duewer]]></surname>
<given-names><![CDATA[D.L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Defining and measuring biological activity: applying the principles of metrology]]></article-title>
<source><![CDATA[Accredit. Qual. Assur]]></source>
<year>2007</year>
<volume>12</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>283-294</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Férard]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Lessinger]]></surname>
<given-names><![CDATA[J.M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Preparation of enzyme calibration materials]]></article-title>
<source><![CDATA[Clin. Chim. Acta]]></source>
<year>1998</year>
<volume>278</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>151-162</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="">
<collab>National Committee for Clinical Laboratory Standards - NCCLS</collab>
<source><![CDATA[C28-A2: How to Define and Determine Reference Intervals in the Clinical Laboratory; Approved Guideline]]></source>
<year>2000</year>
<page-range>172</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schnabl]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Khun]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Adeli]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Pediatric reference intervals: critical gap analysis and establishment of a national initiative]]></article-title>
<source><![CDATA[Electron. J. Int. Fed. Clin. Chem. Lab. Med]]></source>
<year>2008</year>
<volume>19</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>1 - 8</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Horowitz]]></surname>
<given-names><![CDATA[G.L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reference intervals: Practical aspects]]></article-title>
<source><![CDATA[Electron. J. Int. Fed. Clin. Chem. Lab. Med]]></source>
<year>2008</year>
<volume>19</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>1-11</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Stenman]]></surname>
<given-names><![CDATA[U.H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Immunoassay Standardization: Is It Possible , Who Is Responsible , Who Is Capable?]]></article-title>
<source><![CDATA[Clin. Chem]]></source>
<year></year>
<volume>47</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>815-820</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Miller]]></surname>
<given-names><![CDATA[J.N]]></given-names>
</name>
<name>
<surname><![CDATA[Miller]]></surname>
<given-names><![CDATA[J.C]]></given-names>
</name>
</person-group>
<source><![CDATA[Estadistica y quimiometria para quimica analitica]]></source>
<year>2002</year>
<edition>4</edition>
<page-range>296</page-range><publisher-loc><![CDATA[Madrid ]]></publisher-loc>
<publisher-name><![CDATA[Pearson Educacion S.A]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<collab>IUPAC IU of P and AC, Chemistry, IFCC IF of C</collab>
<article-title xml:lang="en"><![CDATA[Expert panel on quantities and units in clinical chemistry (recommendations 1979)]]></article-title>
<source><![CDATA[Pure Appl. Chem. Chem]]></source>
<year>1979</year>
<volume>1</volume>
<page-range>2451-2479</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rigg]]></surname>
<given-names><![CDATA[J.C]]></given-names>
</name>
<name>
<surname><![CDATA[Brown]]></surname>
<given-names><![CDATA[S.S]]></given-names>
</name>
<name>
<surname><![CDATA[Dybkaer]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Olsen]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<source><![CDATA[Compendio de terminología y nomenclatura de propiedades en las ciencias de laboratorio clínico. IUPAC]]></source>
<year>1993</year>
<page-range>125</page-range><publisher-name><![CDATA[Union Internacional de Quimica Pura y Aplicada, e IFCC, Federacion Internacional de Quimica Clinica]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Doumas]]></surname>
<given-names><![CDATA[B.T]]></given-names>
</name>
<name>
<surname><![CDATA[Laessig]]></surname>
<given-names><![CDATA[R.H]]></given-names>
</name>
<name>
<surname><![CDATA[Larson]]></surname>
<given-names><![CDATA[F.C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The sanitized Système International (SI) d'Unités. Opinion]]></article-title>
<source><![CDATA[Clin. Chim. Acta]]></source>
<year>1987</year>
<volume>167</volume>
<page-range>113 - 116</page-range></nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rutledge]]></surname>
<given-names><![CDATA[R.G]]></given-names>
</name>
<name>
<surname><![CDATA[Côté]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Mathematics of quantitative kinetic PCR and the application of stan Dard Curves]]></article-title>
<source><![CDATA[Nucleic Acids Res]]></source>
<year>2003</year>
<volume>31</volume>
<numero>16</numero>
<issue>16</issue>
<page-range>e93</page-range></nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Davies]]></surname>
<given-names><![CDATA[K.W]]></given-names>
</name>
<name>
<surname><![CDATA[Park]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Quality assurance in clinical chemistry laboratories in the UK]]></article-title>
<source><![CDATA[Accredit. Qual. Assur]]></source>
<year>1999</year>
<volume>4</volume>
<page-range>18-26</page-range></nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ibáñez]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[López]]></surname>
<given-names><![CDATA[J.F]]></given-names>
</name>
<name>
<surname><![CDATA[Sahuquillo]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Certified reference materials for analytical mercury speciation in biological and environmental matrices: do they meet user needs?; a review]]></article-title>
<source><![CDATA[Anal. Chim. Acta]]></source>
<year>2012</year>
<numero>720</numero>
<issue>720</issue>
<page-range>9-15</page-range></nlm-citation>
</ref>
<ref id="B35">
<label>35</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[De Biévre]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Dybkaer]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Fajgelj]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Hibbert]]></surname>
<given-names><![CDATA[D.B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Metrological traceability of measurement results in chemistry: Concepts and implementation]]></article-title>
<source><![CDATA[IUPAC Technical Report]]></source>
<year>2011</year>
<volume>83</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>1873-1935</page-range></nlm-citation>
</ref>
<ref id="B36">
<label>36</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Buzoianu]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Aboul-Enein]]></surname>
<given-names><![CDATA[H.Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Clinical reference materials for the validation of the performance of photometric systems used for clinical analyses]]></article-title>
<source><![CDATA[Accredit. Qual. Assur]]></source>
<year>1997</year>
<volume>2</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>375-380</page-range></nlm-citation>
</ref>
<ref id="B37">
<label>37</label><nlm-citation citation-type="">
<collab>International Organization for Standardization</collab>
<source><![CDATA[ISO Guide 35: 2006 Reference materials - General and statistical principles for certification]]></source>
<year>2006</year>
<page-range>72</page-range></nlm-citation>
</ref>
<ref id="B38">
<label>38</label><nlm-citation citation-type="">
<collab>JCTLM Laboratory medicine and vin vitro diagnostics</collab>
<source><![CDATA[List of all available certified reference materials]]></source>
<year>2013</year>
<page-range>1-76</page-range></nlm-citation>
</ref>
<ref id="B39">
<label>39</label><nlm-citation citation-type="">
<collab>Parlamento Europeo y del Consejo</collab>
<source><![CDATA[Directiva 98/79/CE]]></source>
<year>1998</year>
<volume>6</volume>
<page-range>37</page-range></nlm-citation>
</ref>
<ref id="B40">
<label>40</label><nlm-citation citation-type="book">
<collab>BIPM - Bureau International des Poids et Mesures</collab>
<source><![CDATA[]]></source>
<year></year>
<publisher-name><![CDATA[BIPM]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B41">
<label>41</label><nlm-citation citation-type="">
<collab>International Organization for Standardization</collab>
<source><![CDATA[ISO 17511: 2003 In diagnostic medical devices - Measurement of quantities in biological samples - Metrological traceability of values assigned to calibrators and control materials]]></source>
<year>2003</year>
<page-range>23</page-range></nlm-citation>
</ref>
<ref id="B42">
<label>42</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Greg Miller]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Myers]]></surname>
<given-names><![CDATA[G.L]]></given-names>
</name>
<name>
<surname><![CDATA[Lou Gantzer]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Kahn]]></surname>
<given-names><![CDATA[S.E]]></given-names>
</name>
<name>
<surname><![CDATA[Schönbrunner]]></surname>
<given-names><![CDATA[E.R]]></given-names>
</name>
<name>
<surname><![CDATA[Thienpont]]></surname>
<given-names><![CDATA[L.M]]></given-names>
</name>
<name>
<surname><![CDATA[Bunk]]></surname>
<given-names><![CDATA[D.M]]></given-names>
</name>
<name>
<surname><![CDATA[Christenson]]></surname>
<given-names><![CDATA[R.H]]></given-names>
</name>
<name>
<surname><![CDATA[Eckfeldt]]></surname>
<given-names><![CDATA[J.H]]></given-names>
</name>
<name>
<surname><![CDATA[Lo]]></surname>
<given-names><![CDATA[S.F]]></given-names>
</name>
<name>
<surname><![CDATA[Nübling]]></surname>
<given-names><![CDATA[C.M]]></given-names>
</name>
<name>
<surname><![CDATA[Sturgeon]]></surname>
<given-names><![CDATA[C.M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Roadmap for harmonization of clinical laboratory measurement procedures]]></article-title>
<source><![CDATA[Clin. Chem]]></source>
<year>2011</year>
<volume>57</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>1108-1117</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
