<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0120-3347</journal-id>
<journal-title><![CDATA[Colombian Journal of Anestesiology]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. colomb. anestesiol.]]></abbrev-journal-title>
<issn>0120-3347</issn>
<publisher>
<publisher-name><![CDATA[SCARE-Sociedad Colombiana de Anestesiología y Reanimación]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0120-33472010000300009</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Controversias sobre la presión cricoidea o maniobra de Sellick]]></article-title>
<article-title xml:lang="en"><![CDATA[Controversial issue of cricoid pressure or Sellick maneuver]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Páez L]]></surname>
<given-names><![CDATA[John Jairo]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Navarro V]]></surname>
<given-names><![CDATA[J. Ricardo]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad Nacional de Colombia  ]]></institution>
<addr-line><![CDATA[Bogotá ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Universidad Nacional de Colombia Asociado de Anestesiología y Reanimación ]]></institution>
<addr-line><![CDATA[Bogotá ]]></addr-line>
<country>Colombia</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>10</month>
<year>2010</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>10</month>
<year>2010</year>
</pub-date>
<volume>38</volume>
<numero>3</numero>
<fpage>377</fpage>
<lpage>383</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0120-33472010000300009&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0120-33472010000300009&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0120-33472010000300009&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Introducción. La maniobra de Sellick o presión cricoidea es un procedimiento que se realiza de rutina en la profilaxis de la aspiración pulmonar como parte de la inducción/intubación de secuencia rápida. Ha sido objeto de múltiples controversias especialmente sobre su utilidad como práctica estándar de seguridad en el manejo de la vía aérea en urgencias. Se ha considerado la maniobra como una presión, sin embargo se designa la medida en Newton (N), sin tener en cuenta el área del cartílago cricoides, de este modo es preciso referirse a la maniobra no en términos de presión cricoidea sino de fuerza cricoidea Objetivo. Destacar la importancia de revisar las controversias que ha tenido una maniobra que se acerca a los 50 años de vigencia en el manejo de la vía aérea y la prevención de la broncoaspira-ción; incluso resaltar que ha habido errores en su descripción utilizando medidas de fuerza y no de presión. Método. Mediante la revisión de la literatura se realiza este artículo de reflexión sobre las controversias de una maniobra usual en la práctica de urgencias del anestesiólogo, la Maniobra de Sellick. Conclusión. Desde 1961 cuando el doctor Brian Arthur Sellick describió la presión cricoidea como una maniobra útil para prevenir la regurgitación del contenido gástrico hacia la faringe, hasta la actualidad cuando se utiliza como medida importante en la técnica de inducción/intubación de secuencia rápida, se han venido encontrando una serie de controversias en cuanto a la seguridad que puede brindar en el manejo de la vía aérea, dignas de revisar y de discutir, y además, de recomendar una aclaración en cuanto a la designación de los términos presión y fuerza, que se han venido utilizando de manera indistinta para referirse a esta maniobra sin tener en cuenta el área del cartílago cricoides, que de hecho es diferente entre los individuos.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Introduction. The Sellick maneuver or cricoid pressure is a procedure that is routinely performed in the prophylaxis for pulmonary aspiration as part of a rapid sequence intubation. It has been considered very controversial specifically on its usefulness as a standard safety practice in the emergent airway management. It usually has been considered a pressure maneuver, however it usually has seen assessed measuring Newtons (N) without considering the area of the cricoid cartilage. For this reason, it must be understood in terms of cricoid force instead of cricoid pressure. Objetive. To highlight the controversial issues this maneuver has had over the 50 years of its use in airway management and pulmonary aspiration prevention. To explain the common error of describing it in terms of force and not pressure. Methods. Literature review about the controversial aspects of the Sellick maneuver in emergent scenarios in anesthesia. Conclusion. Since the initial description by Dr. Brian Arthur Sellick in 1961 of the maneuver, using cricoid pressure to prevent them regurgitation of gastric contents to the pharynx used as part of the rapid sequence induction/ intubation, there have been multiple criticisms worthwhile to review, regarding the safety it provides in protecting the airway. We recommend that the terms pressure and force be differentiated and be used more appropriately when describing the maneuver, as the area of the cartilage should be considered in these measurements.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[cartílago cricoides]]></kwd>
<kwd lng="es"><![CDATA[presión]]></kwd>
<kwd lng="es"><![CDATA[vértebras cervicales]]></kwd>
<kwd lng="es"><![CDATA[neumonía por aspiración]]></kwd>
<kwd lng="en"><![CDATA[Cricoid cartilage]]></kwd>
<kwd lng="en"><![CDATA[pressure]]></kwd>
<kwd lng="en"><![CDATA[cervical vertebrae]]></kwd>
<kwd lng="en"><![CDATA[acid aspiration syndrome]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <font face="Verdana" size="2">     <p align="right"><b>Art&iacute;culos de Reflexi&oacute;n</b></p>     <p align="center"><b><font face="Verdana" size="3">Controversias sobre la presi&oacute;n cricoidea o maniobra de Sellick</font></b></p>     <p align="center">&nbsp;</p>     <p align="left"><b>John Jairo P&aacute;ez L.*, J. Ricardo Navarro V.**</b></p>     <p>* Estudiante de primer ano de Postgrado de Anestesiolog&iacute;a, de la Universidad Nacional de Colombia. Bogot&aacute;, Colombia. <a href="mailto:jjpaezl@hotmail.com">jjpaezl@hotmail.com</a>.    <br> ** Profesor Asociado de Anestesiolog&iacute;a y Reanimaci&oacute;n, de la Universidad Nacional de Colombia. Bogot&aacute;, Colombia.     <p>Recibido: mayo 16 de 2010. Enviado para modificaciones: junio 7 de 2010. Aceptado: julio 13 de 2010.</p> <hr size="1" />     <p><b><font face="Verdana" size="3">RESUMEN</font></b></p>     <p><b><i>Introducci&oacute;n.</i></b><i> La maniobra de Sellick o presi&oacute;n cricoidea es un procedimiento que se realiza de rutina en la profilaxis de la aspiraci&oacute;n pulmonar como parte de la inducci&oacute;n/intubaci&oacute;n de secuencia r&aacute;pida. Ha sido objeto de m&uacute;ltiples controversias especialmente sobre su utilidad como pr&aacute;ctica est&aacute;ndar de seguridad en el manejo de la v&iacute;a a&eacute;rea en urgencias. Se ha considerado la maniobra como una presi&oacute;n, sin embargo se designa la medida en Newton (N), sin tener en cuenta el &aacute;rea del cart&iacute;lago cricoides, de este modo es preciso referirse a la maniobra no en t&eacute;rminos de presi&oacute;n cricoidea sino de fuerza cricoidea</i></p>     ]]></body>
<body><![CDATA[<p><i><b>Objetivo.</b> Destacar la importancia de revisar las controversias que ha tenido una maniobra que se acerca a los 50 a&ntilde;os de vigencia en el manejo de la v&iacute;a a&eacute;rea y la prevenci&oacute;n de la broncoaspira-ci&oacute;n; incluso resaltar que ha habido errores en su descripci&oacute;n utilizando medidas de fuerza y no de presi&oacute;n.</i></p>     <p><i><b>M&eacute;todo. </b>Mediante la revisi&oacute;n de la literatura se realiza este art&iacute;culo de reflexi&oacute;n sobre las controversias de una maniobra usual en la pr&aacute;ctica de urgencias del anestesi&oacute;logo, la Maniobra de Sellick.</i></p>     <p><i><b>Conclusi&oacute;n.</b> Desde 1961 cuando el doctor Brian Arthur Sellick describi&oacute; la presi&oacute;n cricoidea como una maniobra &uacute;til para prevenir la regurgitaci&oacute;n del contenido g&aacute;strico hacia la faringe, hasta la actualidad cuando se utiliza como medida importante en la t&eacute;cnica de inducci&oacute;n/intubaci&oacute;n de secuencia r&aacute;pida, se han venido encontrando una serie de controversias en cuanto a la seguridad que puede brindar en el manejo de la v&iacute;a a&eacute;rea, dignas de revisar y de discutir, y adem&aacute;s, de recomendar una aclaraci&oacute;n en cuanto a la designaci&oacute;n de los t&eacute;rminos presi&oacute;n y fuerza, que se han venido utilizando de manera indistinta para referirse a esta maniobra sin tener en cuenta el &aacute;rea del cart&iacute;lago cricoides, que de hecho es diferente entre los individuos.</i></p>     <p><i><b><font face="Verdana" size="3">Palabras clave:</font></b> cart&iacute;lago cricoides, presi&oacute;n, v&eacute;rtebras cervicales, neumon&iacute;a por aspiraci&oacute;n</i> (Fuente: DeCS, BIREME).</p> <hr size="1" />     <p><b><font face="Verdana" size="3">INTRODUCCIÓN</font></b></p>     <p>La maniobra de Sellick o presi&oacute;n cricoidea (PC) fue descrita por el anestesi&oacute;logo ingl&eacute;s Brian Arthur Sellick, en 1961 (1), y consiste en aplicar presi&oacute;n hacia atr&aacute;s sobre el cart&iacute;lago cricoides para oprimir y ocluir el es&oacute;fago superior contra las v&eacute;rtebras cervicales y as&iacute; prevenir la regurgitaci&oacute;n de contenido g&aacute;strico a la faringe. Esta maniobra luego fue incluida en la secuencia de inducci&oacute;n/intubaci&oacute;n r&aacute;pida descrita por Safar, en 1970 (2), y ha persistido desde entonces como un pilar en el manejo del est&oacute;mago lleno (3,4). Actualmente, hay mucha controversia acerca de si esta maniobra realmente disminuye la incidencia de aspiraci&oacute;n pulmonar. Para responder esta pregunta mediante un ensayo cl&iacute;nico, se tendr&iacute;an que superar dos grandes obst&aacute;culos. En primera instancia, se necesitar&iacute;a una muestra muy grande de pacientes, dada la baja incidencia de la aspiraci&oacute;n pulmonar (1,4 /10.000 anestesias); segundo se tendr&iacute;an que tener en cuenta los aspectos &eacute;ticos para llevar a cabo esta investigaci&oacute;n, por lo cual la recomendaci&oacute;n actual para su uso cl&iacute;nico es grado D (5).</p>     <p>Neelakanta, en 2003, report&oacute; un caso en el cual s&oacute;lo hasta que al paciente se le liber&oacute; la presi&oacute;n cricoidea, despu&eacute;s de haber sido intubado, present&oacute; abundante contenido l&iacute;quido en su boca; &eacute;sta se considera una de las mejores evidencias de la efectividad de la presi&oacute;n cricoidea en prevenir la aspiraci&oacute;n pulmonar (6). Sin embargo, hay que tener en cuenta muchos otros hallazgos que se han venido registrando desde la introducci&oacute;n de la PC en la pr&aacute;ctica cl&iacute;nica; por ejemplo: 9/12 pacientes, en un estudio prospectivo donde los sujetos ten&iacute;an alto riesgo de aspiraci&oacute;n pulmonar, presentaban infiltrados pulmonares, a pesar de haberles ralizado la PC (7).</p>     <p>Dos casos de s&iacute;ndrome de aspiraci&oacute;n pulmonar fatal ocurrieron a pesar de haber recibido anti&aacute;cidos y PC (8). En un reporte de mortalidad materna en el Reino Unido, entre 1972 y 1975, hubo trece casos de aspiraci&oacute;n pulmonar, cinco de los cuales hab&iacute;an recibido PC de manera incorrecta (9). Williamson report&oacute; tres casos con resultados adversos luego de la PC, uno en quien &eacute;sta ocasion&oacute; hipo antes de la inducci&oacute;n y termin&oacute; en aspiraci&oacute;n pulmonar y muerte; un segundo paciente con contenido de abundante material l&iacute;quido en orofaringe, a pesar de hab&eacute;rsele realizado la PC de manera correcta, y un tercer paciente que la PC le produjo obstrucci&oacute;n de la visibilidad de las cuerdas vocales (10).</p>     <p>Algunos estudios han pretendido determinar la utilidad de la PC enfoc&aacute;ndose en desenlaces secundarios como intubaci&oacute;n exitosa, visi&oacute;n durante la laringoscopia, tono del esf&iacute;nter esof&aacute;gico inferior, insuflaci&oacute;n g&aacute;strica y oclusi&oacute;n esof&aacute;gica evaluada por estudios imaginol&oacute;gicos.</p>     <p>En el estudio de Turgeon y colaboradores, se compar&oacute; la PC frente a la no PC, y se report&oacute; que no hab&iacute;a diferencias en la tasa de intubaciones fallidas ni en la visi&oacute;n durante la laringoscopia (11). Otros resultados en cuanto a la visi&oacute;n la-ringosc&oacute;pica son contradictorios; unos la reportan como una ayuda para acceder a la intubaci&oacute;n traqueal (12), otros no encuentran ning&uacute;n cambio, similar a los resultados obtenidos por Turgeon y colaboradores (11,13), y Snider y colaboradores encontraron serias desventajas con la PC cuando se combina con la maniobra BURP para facilitar la laringoscopia (14). Moynihan y colaboradores encontraron que la PC disminu&iacute;a la insuflaci&oacute;n g&aacute;strica durante la ventilaci&oacute;n con m&aacute;scara en ni&ntilde;os (15).</p>     ]]></body>
<body><![CDATA[<p>Respecto a la anatom&iacute;a de la v&iacute;a a&eacute;rea, se ha asumido que el es&oacute;fago est&aacute; localizado detr&aacute;s del cart&iacute;lago cricoides, y &eacute;ste, a su vez, est&aacute; por delante de la columna cervical a lo largo de un plano axial; sin embargo, cuando se han realizado estudios de tomograf&iacute;a computarizada, se han observado hallazgos controversiales. Smith realiz&oacute; estudios basados en resonancia magn&eacute;tica y encontr&oacute; que en la mitad de los sujetos el es&oacute;fago no se halla detr&aacute;s del cart&iacute;lago cricoides, y cuando se realizaba la PC, &eacute;ste se desplazaba lateralmente en el 90 % de los sujetos (16). Rice, por el contrario, en un estudio en el que tambi&eacute;n utiliz&oacute; la resonancia magn&eacute;tica, observ&oacute; que durante la PC se ocluye la hipofaringe y no el es&oacute;fago, por lo cual la posici&oacute;n de este &uacute;ltimo no es importante (17).</p>     <p>Con este panorama, se puede inferir que la maniobra descrita por Sellick hace ya casi 50 a&ntilde;os involucra muchas variables que incluyen al paciente y al operador (18). El efecto de la presi&oacute;n cricoidea sobre la laringe va a depender de las caracter&iacute;sticas de cada paciente, del m&eacute;todo de aplicaci&oacute;n de la fuerza, de la relaci&oacute;n entre el es&oacute;fago, el cricoides y la columna cervical, de la t&eacute;cnica de la ventilaci&oacute;n, etc. No hay una evidencia fuerte sobre los beneficios en minimizar la distensi&oacute;n g&aacute;strica y disminuir el riesgo de aspiraci&oacute;n pulmonar (19,20).</p>     <p>Como toda opci&oacute;n terap&eacute;utica en medicina, se debe valorar riesgo-beneficio, y como lo afirman Ellis y colaboradores (18), un paciente con alto riesgo de aspiraci&oacute;n pulmonar y bajo riesgo de desaturaci&oacute;n (por ejemplo, paciente con apendi-citis) puede beneficiarse de esta maniobra; a diferencia de un paciente con bajo riesgo de aspiraci&oacute;n y alto riesgo de desaturaci&oacute;n (paciente con hipoxia y taquipnea secundario a una neumon&iacute;a severa), a quien no se le recomendar&iacute;a la PC.</p>     <p>Es controvertida, tambi&eacute;n, la forma como se ha medido la presi&oacute;n cricoidea en la mayor&iacute;a de estos estudios. Sellick no propuso ning&uacute;n m&eacute;todo cuantitativo para determinar la fuerza aplicada durante la PC, &eacute;l s&oacute;lo describi&oacute; la maniobra: &quot;cuando inicia la anestesia, se ejerce una presi&oacute;n sobre el cart&iacute;lago cricoideo&quot;; &quot;un paciente consciente puede tolerar una moderada presi&oacute;n sin malestar&quot;; &quot;tan pronto como se pierda la conscien-cia, se puede aplicar una presi&oacute;n firme&quot; (1,20).</p>     <p>En 1983, Wraight y colaboradores midieron la fuerza sobre el cricoides (producida por un &quot;yugo&quot; cricoideo) para prevenir el reflujo de soluci&oacute;n salina a trav&eacute;s de un tubo traqueal modificado, colocado dentro del es&oacute;fago de 24 pacientes bajo anestesia electiva (21). A partir de estos datos y de medidas previas de presi&oacute;n intrag&aacute;strica en pacientes despiertos, ellos estimaron que la presi&oacute;n cricoidea para prevenir la aspiraci&oacute;n pulmonar de pacientes que requer&iacute;an anestesia de emergencia correspond&iacute;a a 44 N (9,81 N = 1 kg = 2,2 lb).</p>     <p>Clayton y Vanner (22) propusieron que al aplicar una fuerza hacia atr&aacute;s sobre el cart&iacute;lago cricoi-des se altera la medici&oacute;n del peso de la persona que aplica la fuerza; es decir, si la persona que aplica la fuerza sobre el cricoides se para sobre una b&aacute;scula, presentar&aacute; una disminuci&oacute;n aparente de 1 kg de peso, que corresponde a una fuerza de 9,81 N (newton). Con estos datos, el peso que se aplica en la mayor&iacute;a de los estudios (aproximadamente 2,5 a 3 kg), corresponder&iacute;a a una fuerza entre 25 N y 30 N, que es la recomendada cuando se realiza la PC.</p>     <p>De esto surge otra controversia: ¿Por qu&eacute; se usan unidades de fuerza para cuantificar una presi&oacute;n? Seg&uacute;n el sistema internacional de pesos y medidas, la presi&oacute;n es definida como la fuerza ejercida por unidad de &aacute;rea, y su unidad es el pascal, que corresponde a una fuerza de 1 newton ejercida sobre un &aacute;rea de 1 metro cuadrado (23). Por lo tanto, la presi&oacute;n cricoidea deber&iacute;a estar reportada en pascales, o en otras unidades de presi&oacute;n, como mmHg o cmH2O, y no en unidades de fuerza o de masa, porque as&iacute; se est&aacute; dejando de apreciar un componente importante: el &aacute;rea del cart&iacute;lago cricoides.</p>     <p>Al tener en cuenta estos par&aacute;metros, una fuerza de 30 N sobre un &aacute;rea de 6,25 cm2 (el &aacute;rea de la l&aacute;mina del cricoides es de 4 a 9 cm2), ejerce una presi&oacute;n de 48 kPa (kilopascales), mientras que la misma fuerza sobre un &aacute;rea de 4 cm2 ejerce una presi&oacute;n de 74 kPa, que es mucho mayor que la primera y podr&iacute;a causar alteraciones en la visi&oacute;n laringosc&oacute;pica. Este puede ser un factor importante en la variaci&oacute;n de los resultados de los estudios de PC.</p>     <p>Hay dos posibles soluciones para este problema: cambiar la magnitud con la que se mide la presi&oacute;n cricoidea (pascales o mmHg) o cambiar el nombre de la maniobra a fuerza cricoidea. Aunque parezcan detalles insignificantes, no es bien visto que la medicina, una ciencia verificable, no mida adecuadamente alguna magnitud usada en sus estudios.</p>     <p>Futuros trabajos sobre la presi&oacute;n cricoidea deben cuantificar la presi&oacute;n con unidades precisas y adecuadas, y tener en cuenta el &aacute;rea del cart&iacute;lago cricoides, que puede ser otro factor de variaci&oacute;n en la efectividad de la maniobra.</p>     ]]></body>
<body><![CDATA[<p>Como conclusi&oacute;n, la maniobra de Sellick es un procedimiento que se ha venido utilizando en la profilaxis de la aspiraci&oacute;n pulmonar como parte de la inducci&oacute;n/intubaci&oacute;n de secuencia r&aacute;pida; sin embargo, hay muchas controversias alrededor de ella y a&uacute;n no se puede considerar una pr&aacute;ctica est&aacute;ndar de seguridad en el manejo de la v&iacute;a a&eacute;rea basada en la evidencia, incluso los autores resaltan el error de considerar la maniobra como una presi&oacute;n, cuando se designa la medida en newtons, sin tener en cuenta el &aacute;rea del cart&iacute;lago cricoides. De esta forma, ser&iacute;a correcto no referirse en t&eacute;rminos de presi&oacute;n cricoidea, sino de fuerza cricoidea.</p>     <p><b><font face="Verdana" size="3">REFERENCIAS</font></b></p>     <!-- ref --><p>1.&nbsp;Sellick BA. Cricoid pressure to control regurgitation of stomach contents during induction of anaesthesia. Lancet. 1961;2(7199):404-6.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000035&pid=S0120-3347201000030000900001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>2.&nbsp;Stept WJ, Safar P. Rapid induction/intubation for prevention of gastric-content aspiration. Anesth An-alg. 1970;49(4):633-6.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000036&pid=S0120-3347201000030000900002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>3.&nbsp;Rosen M. Anaesthesia for obstetrics. Anaesthesia. 1981;36(2):145-6.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000037&pid=S0120-3347201000030000900003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>4.&nbsp;Kron SS. Questionable effectiveness of cricoid pressure in preventing aspiration. Anesthesiology. 1995; 83(2):431-2.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000038&pid=S0120-3347201000030000900004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>5.&nbsp;Neilipovitz DT, Crosby ET. No evidence for decreased incidence of aspiration after rapid sequence induction. Can J Anaesth. 2007;54(9):748-64.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000039&pid=S0120-3347201000030000900005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>6.&nbsp;Neelakanta G. Cricoid pressure is effective in preventing esophageal regurgitation. Anaesthesiology. 2003;99(1):242.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000040&pid=S0120-3347201000030000900006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>7.&nbsp;Howells TH, Chamney AR, Wraight WJ, Simons RS. The application of cricoids pressure. An assessment and survey of its practice. Anaesthesia. 1983;38(5):457-60.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000041&pid=S0120-3347201000030000900007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>8.&nbsp;Whittington RM, Robinson JS, Thompson JM. Fatal aspiration (Mendelson's) syndrome despite antacids and cricoids pressure. Lancet. 1979;314(8136):228-30.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000042&pid=S0120-3347201000030000900008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>9.&nbsp;Moir DD. Maternal mortality and anaesthesia. Br J Anaesth. 1980;52(1):1-3&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000043&pid=S0120-3347201000030000900009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>10.&nbsp;Williamson R. Cricoid pressure. Can J Anaesth. 1989;36(5):601.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000044&pid=S0120-3347201000030000900010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>11.&nbsp;Turgeon AF, Nicole PC, Trepanier CA, Marcoux S, Lessard MR. Cricoid pressure does not increase the rate of failed intubation by direct laryngoscopy in adults. Anesthesiology. 2005; 102(2):315-9.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000045&pid=S0120-3347201000030000900011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>12.&nbsp;Vanner RG, Clarke P, Moore W, Raftery S. The effect of cricoid pressure and neck support on the view at layngoscopy. Anaesthesia. 1997;52(9):896-900.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000046&pid=S0120-3347201000030000900012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>13.&nbsp;Brimacombe J, White A, Berry A. Effect of cricoid pressure on the ease of insertion of the laryngeal mask airway. Br J Anaesth. 1993;71(6):800-2.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000047&pid=S0120-3347201000030000900013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>14.&nbsp;Snider DD, Clarke D, Finucane BT. The &quot;BURP&quot; maneuver worsens the glotic view when applied in combination with cricoid pressure. Can J Anaesth. 2005;52(1):100-4.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000048&pid=S0120-3347201000030000900014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>15.&nbsp;Moynihan RJ, Brock-Utne JG, Archer JH, Feld LH, Kreitzman TR. The effect of cricoid pressure on preventing gastric insufflation in infants and children. Anesthesiology. 1993;78(4):652-6.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000049&pid=S0120-3347201000030000900015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>16.&nbsp;Smith KJ, Dobranowski J, Yip G, Dauphin A, Choi PT. Cricoid pressure displaces the esophagus: an observational study using magnetic resonance imaging. Anesthesiology. 2003;99(1):60-4.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000050&pid=S0120-3347201000030000900016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>17.&nbsp;Rice MJ, Mancuso AA, Gibbs C, Morey TE, Gravenstein N, Deitte LA. Cricoid pressure results in compression of the postcricoid hypopharynx: the esophageal position is irrelevant. Anesth Analg. 2009;109(5):1546-52.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000051&pid=S0120-3347201000030000900017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>18.&nbsp;Ellis DY, Harris T, Zideman D. Cricoid pressure in emergency department rapid sequence Tracheal intubations: a risk-benefit analysis. Ann Emerg Med. 2007;50(6):653-65.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000052&pid=S0120-3347201000030000900018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>19.&nbsp;Brimacombe JR, Berry AM. Cricoid pressure. Can J Anaesth. 1997;44(4):414-25.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000053&pid=S0120-3347201000030000900019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>20.&nbsp;Priebe HJ. Cricoid pressure: an alternative view. Semin Anesth Per Med Pain. 2005;24(2):120-6.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000054&pid=S0120-3347201000030000900020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>21.&nbsp;Wraight WJ, Chamney AR, Howells TH. The determination of an effective cricoid pressure. Anaesthesia. 1983;38(5):461-6.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000055&pid=S0120-3347201000030000900021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>22.&nbsp;Clayton TJ, Vanner RG. A novel method of measuring cricoid force. Anaesthesia 2002;57(4):326-9.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000056&pid=S0120-3347201000030000900022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>23.&nbsp;Mushambi M, Smith G. Basic physics for the anaesthetist. In: Textbook of anaesthesia. 4th Ed. London: Churchill Livingstone; 2001. p. 373-408.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000057&pid=S0120-3347201000030000900023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><p><font size="2" face="Verdana"><b>Conflicto de intereses:</b> ninguno declarado. </font></p>       ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sellick]]></surname>
<given-names><![CDATA[BA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cricoid pressure to control regurgitation of stomach contents during induction of anaesthesia]]></article-title>
<source><![CDATA[Lancet.]]></source>
<year>1961</year>
<volume>2</volume>
<numero>7199</numero>
<issue>7199</issue>
<page-range>404-6</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Stept]]></surname>
<given-names><![CDATA[WJ]]></given-names>
</name>
<name>
<surname><![CDATA[Safar]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Rapid induction/intubation for prevention of gastric-content aspiration]]></article-title>
<source><![CDATA[Anesth An-alg.]]></source>
<year>1970</year>
<volume>49</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>633-6</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rosen]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Anaesthesia for obstetrics]]></article-title>
<source><![CDATA[Anaesthesia.]]></source>
<year>1981</year>
<volume>36</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>145-6</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kron]]></surname>
<given-names><![CDATA[SS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Questionable effectiveness of cricoid pressure in preventing aspiration]]></article-title>
<source><![CDATA[Anesthesiology.]]></source>
<year>1995</year>
<volume>83</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>431-2</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Neilipovitz]]></surname>
<given-names><![CDATA[DT]]></given-names>
</name>
<name>
<surname><![CDATA[Crosby]]></surname>
<given-names><![CDATA[ET]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[No evidence for decreased incidence of aspiration after rapid sequence induction]]></article-title>
<source><![CDATA[Can J Anaesth.]]></source>
<year>2007</year>
<volume>54</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>748-64</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Neelakanta]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cricoid pressure is effective in preventing esophageal regurgitation]]></article-title>
<source><![CDATA[Anaesthesiology.]]></source>
<year>2003</year>
<volume>99</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>242</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Howells]]></surname>
<given-names><![CDATA[TH]]></given-names>
</name>
<name>
<surname><![CDATA[Chamney]]></surname>
<given-names><![CDATA[AR]]></given-names>
</name>
<name>
<surname><![CDATA[Wraight]]></surname>
<given-names><![CDATA[WJ]]></given-names>
</name>
<name>
<surname><![CDATA[Simons]]></surname>
<given-names><![CDATA[RS.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An assessment and survey of its practice]]></article-title>
<source><![CDATA[Anaesthesia.]]></source>
<year>1983</year>
<volume>38</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>457-60</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Whittington]]></surname>
<given-names><![CDATA[RM]]></given-names>
</name>
<name>
<surname><![CDATA[Robinson]]></surname>
<given-names><![CDATA[JS]]></given-names>
</name>
<name>
<surname><![CDATA[Thompson]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fatal aspiration (Mendelson's) syndrome despite antacids and cricoids pressure]]></article-title>
<source><![CDATA[Lancet.]]></source>
<year>1979</year>
<volume>314</volume>
<numero>8136</numero>
<issue>8136</issue>
<page-range>228-30</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Moir]]></surname>
<given-names><![CDATA[DD]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Maternal mortality and anaesthesia]]></article-title>
<source><![CDATA[Br J Anaesth.]]></source>
<year>1980</year>
<volume>52</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>1-3</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Williamson]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cricoid pressure]]></article-title>
<source><![CDATA[Can J Anaesth.]]></source>
<year>1989</year>
<volume>36</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>601</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Turgeon]]></surname>
<given-names><![CDATA[AF]]></given-names>
</name>
<name>
<surname><![CDATA[Nicole]]></surname>
<given-names><![CDATA[PC]]></given-names>
</name>
<name>
<surname><![CDATA[Trepanier]]></surname>
<given-names><![CDATA[CA]]></given-names>
</name>
<name>
<surname><![CDATA[Marcoux]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Lessard]]></surname>
<given-names><![CDATA[MR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cricoid pressure does not increase the rate of failed intubation by direct laryngoscopy in adults]]></article-title>
<source><![CDATA[Anesthesiology.]]></source>
<year>2005</year>
<volume>102</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>315-9</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vanner]]></surname>
<given-names><![CDATA[RG]]></given-names>
</name>
<name>
<surname><![CDATA[Clarke]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Moore]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Raftery]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The effect of cricoid pressure and neck support on the view at layngoscopy]]></article-title>
<source><![CDATA[Anaesthesia.]]></source>
<year>1997</year>
<volume>52</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>896-900</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Brimacombe]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[White]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Berry]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of cricoid pressure on the ease of insertion of the laryngeal mask airway]]></article-title>
<source><![CDATA[Br J Anaesth.]]></source>
<year>1993</year>
<volume>71</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>800-2</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Snider]]></surname>
<given-names><![CDATA[DD]]></given-names>
</name>
<name>
<surname><![CDATA[Clarke]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Finucane]]></surname>
<given-names><![CDATA[BT]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The "BURP" maneuver worsens the glotic view when applied in combination with cricoid pressure]]></article-title>
<source><![CDATA[Can J Anaesth.]]></source>
<year>2005</year>
<volume>52</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>100-4</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Moynihan]]></surname>
<given-names><![CDATA[RJ]]></given-names>
</name>
<name>
<surname><![CDATA[Brock-Utne]]></surname>
<given-names><![CDATA[JG]]></given-names>
</name>
<name>
<surname><![CDATA[Archer]]></surname>
<given-names><![CDATA[JH]]></given-names>
</name>
<name>
<surname><![CDATA[Feld]]></surname>
<given-names><![CDATA[LH]]></given-names>
</name>
<name>
<surname><![CDATA[Kreitzman]]></surname>
<given-names><![CDATA[TR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The effect of cricoid pressure on preventing gastric insufflation in infants and children]]></article-title>
<source><![CDATA[Anesthesiology.]]></source>
<year>1993</year>
<volume>78</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>652-6</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Smith]]></surname>
<given-names><![CDATA[KJ]]></given-names>
</name>
<name>
<surname><![CDATA[Dobranowski]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Yip]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Dauphin]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Choi]]></surname>
<given-names><![CDATA[PT]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cricoid pressure displaces the esophagus: an observational study using magnetic resonance imaging]]></article-title>
<source><![CDATA[Anesthesiology.]]></source>
<year>2003</year>
<volume>99</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>60-4</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rice]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[Mancuso]]></surname>
<given-names><![CDATA[AA]]></given-names>
</name>
<name>
<surname><![CDATA[Gibbs]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Morey]]></surname>
<given-names><![CDATA[TE]]></given-names>
</name>
<name>
<surname><![CDATA[Gravenstein]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Deitte]]></surname>
<given-names><![CDATA[LA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cricoid pressure results in compression of the postcricoid hypopharynx: the esophageal position is irrelevant]]></article-title>
<source><![CDATA[Anesth Analg.]]></source>
<year>2009</year>
<volume>109</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>1546-52</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ellis]]></surname>
<given-names><![CDATA[DY]]></given-names>
</name>
<name>
<surname><![CDATA[Harris]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Zideman]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cricoid pressure in emergency department rapid sequence Tracheal intubations: a risk-benefit analysis]]></article-title>
<source><![CDATA[Ann Emerg Med.]]></source>
<year>2007</year>
<volume>50</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>653-65</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Brimacombe]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Berry]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cricoid pressure]]></article-title>
<source><![CDATA[Can J Anaesth.]]></source>
<year>1997</year>
<volume>44</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>414-25</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Priebe]]></surname>
<given-names><![CDATA[HJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cricoid pressure: an alternative view]]></article-title>
<source><![CDATA[Semin Anesth Per Med Pain.]]></source>
<year>2005</year>
<volume>24</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>120-6</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wraight]]></surname>
<given-names><![CDATA[WJ]]></given-names>
</name>
<name>
<surname><![CDATA[Chamney]]></surname>
<given-names><![CDATA[AR]]></given-names>
</name>
<name>
<surname><![CDATA[Howells]]></surname>
<given-names><![CDATA[TH]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The determination of an effective cricoid pressure]]></article-title>
<source><![CDATA[Anaesthesia.]]></source>
<year>1983</year>
<volume>38</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>461-6</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Clayton]]></surname>
<given-names><![CDATA[TJ]]></given-names>
</name>
<name>
<surname><![CDATA[Vanner]]></surname>
<given-names><![CDATA[RG]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A novel method of measuring cricoid force]]></article-title>
<source><![CDATA[Anaesthesia]]></source>
<year>2002</year>
<volume>57</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>326-9</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mushambi]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Smith]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Basic physics for the anaesthetist]]></article-title>
<source><![CDATA[Textbook of anaesthesia]]></source>
<year>2001</year>
<edition>4</edition>
<page-range>373-408</page-range><publisher-loc><![CDATA[London ]]></publisher-loc>
<publisher-name><![CDATA[Churchill Livingstone]]></publisher-name>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>
