<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0120-3347</journal-id>
<journal-title><![CDATA[Colombian Journal of Anestesiology]]></journal-title>
<abbrev-journal-title><![CDATA[Rev. colomb. anestesiol.]]></abbrev-journal-title>
<issn>0120-3347</issn>
<publisher>
<publisher-name><![CDATA[SCARE-Sociedad Colombiana de Anestesiología y Reanimación]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0120-33472012000400005</article-id>
<article-id pub-id-type="doi">10.1016/j.rca.2012.05.014</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Cateterismo de la arteria radial para monitorización invasiva: evitar las complicaciones, un reto en anestesia]]></article-title>
<article-title xml:lang="en"><![CDATA[Radial artery catheterism for invasive monitoring: Preventing complications, a challenge in anesthesia]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Chaparro Mendoza]]></surname>
<given-names><![CDATA[Katheryne]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Fundación Clínica Valle del Lili  ]]></institution>
<addr-line><![CDATA[Cali ]]></addr-line>
<country>Colombia</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2012</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2012</year>
</pub-date>
<volume>40</volume>
<numero>4</numero>
<fpage>262</fpage>
<lpage>265</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0120-33472012000400005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0120-33472012000400005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0120-33472012000400005&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Introducción: La canalización de la arteria radial es una intervención común en anestesia. La falsa sensación de seguridad en su uso proviene de la relativa escasa frecuencia de complicaciones. Identificar los principales factores asociados y las controversias aún existentes son elementos esenciales en el desafío de evitar complicaciones. Método: Se presenta el caso de una mujer llevada a cirugía que presentó lesión isquémica permanente en la mano después de la inserción de un catéter en la arteria radial. Se realiza una revisión reflexiva de la literatura sobre los factores de riesgo y las controversias sobre las intervenciones que han sido implementadas para prevenir las complicaciones. Resultados: La canalización de la arteria radial puede generar lesiones isquémicas permanentes hasta en un 0,09%. El 38% de los casos presenta trombosis con la canalización, el riesgo aumenta con el tiempo de canalización y permanece aun después de la decanulación. El test de Allen ha demostrado no ser adecuado para predecir lesiones isquémicas. Factores como la edad, el tabaquismo, la diabetes mellitus, la insuficiencia renal y la hipertensión arterial son reconocidos como riesgo para ateromatosis de la arterial radial. Otros elementos, como el tamaño y el material del catéter, han sido asociados con el riesgo de complicaciones. Las perfusiones a través del catéter permanecen en controversia y la canalización guiada con ultrasonido solo facilita el procedimiento. Conclusiones:Definitivamente este procedimiento no está exento de riesgos, y aunque muchos factores han sido claramente documentados, no es posible controlarlos todos y las intervenciones dirigidas a prevenirlas no han demostrado ser eficaces.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Introduction: Radial artery line placement is a common intervention in anesthesia. There Arteries is a sensation of false safety generated by the relatively low complication incidence. Identification of the primary association factors and controversies on the matter are key for prevention of complications. Methods: We presents the case of a female patient who suffered permanent ischemia in her hand after inserting a catheter in the radial artery. A reflexive review of the literature on risk factors and controversies on interventions that have been implemented is included. Results:Placing a line in the radial artery may cause permanent ischemic injuries in as much as 0,09% of cases. Thirty-eight per cent of cases develop thrombosis with the procedure, the risk of thrombosis increases over time and remains even after removing the cannula. The Allen test has shown to be a poorpredictor of ischemic lesions. Age, use of tobacco, diabetes, renal failure and arterial hypertension are all risk factors for radial artery atheromatosis. Other elements such as the size and the material the catheter is made of have also been related to the risk of complications. Infusions through the catheter remain a controversy. Ultrasound guides for catheterism eases the procedure. Conclusions: This procedure is definitely not without risks. Even though many factors have been carefully documented they cannot be fully controlled and interventions aimed at prevention have not been proven to be effective.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Arterias]]></kwd>
<kwd lng="es"><![CDATA[Arteria radial]]></kwd>
<kwd lng="es"><![CDATA[Catéteres de permanencia]]></kwd>
<kwd lng="es"><![CDATA[Monitores de presión sanguínea]]></kwd>
<kwd lng="en"><![CDATA[Arteries]]></kwd>
<kwd lng="en"><![CDATA[Radial artery]]></kwd>
<kwd lng="en"><![CDATA[Catheters indwelling]]></kwd>
<kwd lng="en"><![CDATA[Blood pressure monitors]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  <font size="2" face="Verdana">     <p><a href="http://dx.doi.org/10.1016/j.rca.2012.05.014" target="_blank">http://dx.doi.org/10.1016/j.rca.2012.05.014</a></p>      <p align="right">Reflexi&oacute;n</p>      <p align="center"><b><font size="4" face="Verdana">Cateterismo de la arteria radial para monitorizaci&oacute;n invasiva: evitar las complicaciones, un reto en anestesia</font></b></p>     <p align="center"><b><font size="3" face="Verdana">Radial artery catheterism for invasive monitoring: Preventing complications, a challenge in anesthesia</font></b></p>      <p> </p>     <p><b>Katheryne Chaparro Mendoza *</b></p>     <p>Anestesi&oacute;loga, Fundaci&oacute;n Cl&iacute;nica Valle del Lili, Hospital Universitario del Valle, Cali, Colombia.</p>      <p>* Autor para correspondencia: Calle 45 # 99-39 Apto 401 E unidad residencial Entreparques. Cali, Colombia. Correo electr&oacute;nico: <a href="mailto:jacok20@hotmail.com">jacok20@hotmail.com</a>    <br> &copy; 2012 Publicado por Elsevier Espa&ntilde;a, S.L. en nombre de Sociedad Colombiana de Anestesiolog&iacute;a y Reanimaci&oacute;n.</p> <hr> INFORMACI&Oacute;N DEL ART&Iacute;CULO      ]]></body>
<body><![CDATA[<p>Historia del art&iacute;culo: Recibido el 20 de enero de 2012 Aceptado el 19 de mayo de 2012    <br>    On-line el 12 de julio de 2012.</p> <b><font size="3">Resumen</font></b>     <p><b>Introducci&oacute;n</b>: La canalizaci&oacute;n de la arteria radial es una intervenci&oacute;n com&uacute;n en anestesia. La falsa sensaci&oacute;n de seguridad en su uso proviene de la relativa escasa frecuencia de complicaciones. Identificar los principales factores asociados y las controversias a&uacute;n existentes son elementos esenciales en el desaf&iacute;o de evitar complicaciones.</p>     <p><b>M&eacute;todo</b>: Se presenta el caso de una mujer llevada a cirug&iacute;a que present&oacute; lesi&oacute;n isqu&eacute;mica permanente en la mano despu&eacute;s de la inserci&oacute;n de un cat&eacute;ter en la arteria radial. Se realiza una revisi&oacute;n reflexiva de la literatura sobre los factores de riesgo y las controversias sobre las intervenciones que han sido implementadas para prevenir las complicaciones. Resultados: La canalizaci&oacute;n de la arteria radial puede generar lesiones isqu&eacute;micas permanentes hasta en un 0,09%. El 38% de los casos presenta trombosis con la canalizaci&oacute;n, el riesgo aumenta con el tiempo de canalizaci&oacute;n y permanece aun despu&eacute;s de la decanulaci&oacute;n. El test de Allen ha demostrado no ser adecuado para predecir lesiones isqu&eacute;micas. Factores como la edad, el tabaquismo, la diabetes mellitus, la insuficiencia renal y la hipertensi&oacute;n arterial son reconocidos como riesgo para ateromatosis de la arterial radial. Otros elementos, como el tama&ntilde;o y el material del cat&eacute;ter, han sido asociados con el riesgo de complicaciones. Las perfusiones a trav&eacute;s del cat&eacute;ter permanecen en controversia y la canalizaci&oacute;n guiada con ultrasonido solo facilita el procedimiento.</p>     <p><b>Conclusiones</b>:Definitivamente este procedimiento no est&aacute; exento de riesgos, y aunque muchos factores han sido claramente documentados, no es posible controlarlos todos y las intervenciones dirigidas a prevenirlas no han demostrado ser eficaces.</p>      <p><b>Palabras clave</b>:Arterias, Arteria radial, Cat&eacute;teres de permanencia, Monitores de presi&oacute;n sangu&iacute;nea.</p>      <p>&copy; 2012 Publicado por Elsevier Espa&ntilde;a, S.L. en nombre de Sociedad Colombiana de Anestesiolog&iacute;a y Reanimaci&oacute;n.</p> <hr>      <p><font size="3" face="Verdana"><b>Abstract</b></font></p> <b>Introduction</b>: Radial artery line placement is a common intervention in anesthesia. There Arteries is a sensation of false safety generated by the relatively low complication incidence. Identification   of the primary association factors and controversies on the matter are key for  prevention of complications.     <p><b>Methods</b>: We presents the case of a female patient who suffered permanent ischemia in her hand after inserting a catheter in the radial artery. A reflexive review of the literature on risk factors and controversies on interventions that have been implemented is included.</p>     <p> <b>Results</b>:Placing a line in the radial artery may cause permanent ischemic injuries in as much as 0,09% of cases. Thirty-eight per cent of cases develop thrombosis with the procedure, the risk of thrombosis increases over time and remains even after removing the cannula. The Allen test has shown to be a poorpredictor of ischemic lesions. Age, use of tobacco, diabetes, renal failure and arterial hypertension are all risk factors for radial artery atheromatosis. Other elements such as the size and the material the catheter is made of have also been related to the risk of complications. Infusions through the catheter remain a controversy. Ultrasound guides for catheterism eases the procedure.</p>      ]]></body>
<body><![CDATA[<p><b>Conclusions</b>: This procedure is definitely not without risks. Even though many factors have been carefully documented they cannot be fully controlled and interventions aimed at prevention have not been proven to be effective.</p>     <p><b>Keywords:</b> Arteries,   Radial artery,   Catheters indwelling,  Blood pressure monitors.</p>     <p>&copy; 2012 Published by Elsevier Espa&ntilde;a, S.L. on behalf of Sociedad Colombiana de Anestesiolog&iacute;a y Reanimaci&oacute;n.</p>  <hr>      <p>Una mujer de 31 a&ntilde;os de edad fue hospitalizada para trasplante renal y pancre&aacute;tico, con diagn&oacute;stico de s&iacute;ndrome poliglandular autoinmune, hipotiroidismo, diabetes mellitus insulinodependiente, insuficiencia renal cr&oacute;nica estadio 5 e hipertensi&oacute;n arterial. Se realiz&oacute; inducci&oacute;n anest&eacute;sica endovenosa y mantenimiento con anestesia balanceada. Se instaur&oacute; monitorizaci&oacute;n invasiva a trav&eacute;s de un cat&eacute;ter venoso central yugular interno izquierdo, se canaliz&oacute; la arteria radial izquierda con un angiocat n.&deg; 20 tras m&uacute;ltiples intentos y se inici&oacute; perfusi&oacute;n de heparina, 2U/ml, a trav&eacute;s de la misma. El procedimiento transcurri&oacute; sin requerimiento de soporte vasopresor. Despu&eacute;s de 6 h de cirug&iacute;a la paciente fue extubada y se traslad&oacute; a la unidad de cuidados intensivos, donde se le retir&oacute; el cat&eacute;ter arterial 24 h m&aacute;s tarde. Al tercer d&iacute;a posquir&uacute;rgico la paciente refiri&oacute; dolor en el tercer dedo de la mano izquierda, y al cuarto d&iacute;a se evidenci&oacute; cianosis y frialdad en el segundo y tercer dedos de la mano izquierda con llenado capilar lento, pulso radial presente y sim&eacute;trico en relaci&oacute;n con la otra extremidad. El manejo inicial fue con hidromorfona, sin lograr el adecuado control del dolor, por lo cual al octavo d&iacute;a posquir&uacute;rgico se le realiz&oacute; un bloqueo del ganglio estrellado izquierdo, tras el cual present&oacute; disminuci&oacute;n parcial del dolor sin cambios cl&iacute;nicos del fen&oacute;meno isqu&eacute;mico. El doppler arterial del miembro superior izquierdo evidenci&oacute; disminuci&oacute;n del calibre de la arteria radial con flujo laminar y ecocardiograma transesof&aacute;gico que descart&oacute; fen&oacute;meno cardioemb&oacute;lico. El servicio de cirug&iacute;a vascular decidi&oacute; manejo expectante, anticoagulaci&oacute;n con heparina no fraccionada y uso de calcioantagonistas. La cl&iacute;nica del dolor realiz&oacute; titulaci&oacute;n de opi&aacute;ceos y gabapentina para el manejo del dolor. El d&iacute;a 14 se le realiz&oacute; nuevamente un bloqueo del ganglio estrellado izquierdo sin que presentara mejor&iacute;a de los s&iacute;ntomas, evolucionando con necrosis severa hasta la falange proximal del tercer dedo de la mano izquierda, que finalmente requiri&oacute; amputaci&oacute;n un mes despu&eacute;s.</p>     <p>Insertar un cat&eacute;ter intraarterial para monitorizar de forma invasiva la presi&oacute;n arterial es una intervenci&oacute;n frecuente en anestesia, con indicaciones claras como el requerimiento de monitorizaci&oacute;n continua en tiempo real de la presi&oacute;n arterial, manipulaci&oacute;n cardiovascular farmacol&oacute;gica o mec&aacute;nica, extracci&oacute;n repetida de muestras sangu&iacute;neas, incapacidad para la determinaci&oacute;n indirecta de la presi&oacute;n arterial, requerimiento de informaci&oacute;n diagn&oacute;stica a partir de la onda y determinaci&oacute;n de la respuesta al volumen a partir de la presi&oacute;n sist&oacute;lica o la variabilidad de la presi&oacute;n de pulso<sup>1</sup>. La arteria radial es el sitio preferido para la canalizaci&oacute;n por su f&aacute;cil acceso, su simplicidad y su escaso mantenimiento. Aunque poco comunes, la mayor&iacute;a de las complicaciones tras la canalizaci&oacute;n son asintom&aacute;ticas y se resuelven espont&aacute;neamente<sup>2</sup>. Se ha documentado lesi&oacute;n isqu&eacute;mica permanente de la mano en el 0,09% de los casos, as&iacute; como sepsis (0,13%), infecci&oacute;n local (0,72%), pseudoaneurisma (0,09%), hematoma (14%) y sangrado (0,5%)<sup>3</sup>.</p>     <p>Bedford y Wollman<sup>4</sup> documentaron trombosis en el 38,5% de los casos tras la canalizaci&oacute;n de la arteria radial, con permanencia del flujo distal evidenciado por doppler en el 92,5% de los casos y por pulso palpable en el 72,5%, secundario a la circulaci&oacute;n colateral por la arteria ulnar. Tambi&eacute;n encontraron relaci&oacute;n entre la formaci&oacute;n de trombos y el tiempo de canalizaci&oacute;n, que fue mayor despu&eacute;s de 20 h. Se identificaron casos de trombosis y vasoespasmo aun despu&eacute;s de la decanulaci&oacute;n, donde solo el 10% de los casos manifestaron signos cl&iacute;nicos de compromiso vascular que se resolvieron a los 7 d&iacute;as. El retorno de la permeabilidad de algunas de las arterias comprometidas se demor&oacute; hasta 75 d&iacute;as. Por otra parte, Slogoff y Keats<sup>5</sup> encontraron que m&aacute;s del 25% de los pacientes presentaban oclusi&oacute;n parcial o completa de la arteria radial, pero ninguno mostr&oacute; signos cl&iacute;nicos de isquemia, los cuales se ha descrito que pueden aparecer tard&iacute;amente —como en el caso de esta paciente— y estar acompa&ntilde;ados de la presencia de pulso radial, de modo que el diagn&oacute;stico puede requerir el uso de elementos como el eco-doppler y la angiograf&iacute;a.</p>     <p>Hasta este momento se reconoc&iacute;a la alta incidencia de compromiso del flujo arterial tras la inserci&oacute;n de cat&eacute;teres evidenciado por doppler, por lo cual se dirigi&oacute; la atenci&oacute;n a la b&uacute;squeda de elementos que pudieran predecir dicha complicaci&oacute;n. El test de Allen se ha utilizado para evaluar la calidad de la circulaci&oacute;n colateral de la mano durante la oclusi&oacute;n temporal de la arteria radial para predecir lesi&oacute;n isqu&eacute;mica si dicha circulaci&oacute;n se interrumpe permanentemente. En un estudio de Slogoff, solo el 3,9% presentaron un test de Allen anormal y ninguno de ellos present&oacute; complicaciones tras ser canalizados, concluyendo que el test de Allen no es un buen predictor de isquemia en ausencia de enfermedad vascular. Barone y Madlinger<sup>6</sup> realizaron una revisi&oacute;n de la literatura, encontrando que no hay acuerdo sobre cu&aacute;ndo un test es anormal y ni sobre su significado; por lo tanto, no se considera adecuado para predecir complicaciones.</p>     <p>Estudios en pacientes llevados a revascularizaci&oacute;n mioc&aacute;rdica han revelado que la edad mayor de 50 a&ntilde;os, el tabaquismo, la hipertensi&oacute;n arterial, la diabetes mellitus y la insuficiencia renal cr&oacute;nica son los factores m&aacute;s asociados con el desarrollo de hiperplasia, calcificaci&oacute;n y ateromatosis de la arteria radial<sup>7</sup>, sugiriendo que aunque se trataba de una paciente joven, sus comorbilidades eran el principal factor de riesgo para el desarrollo de complicaciones con la monitorizaci&oacute;n invasiva.</p>     <p>Los factores de riesgo asociados a las complicaciones de la canalizaci&oacute;n arterial son el tiempo de canalizaci&oacute;n (m&aacute;s de 20 h), el material del cat&eacute;ter, el tama&ntilde;o del cat&eacute;ter, la punta cerrada del cat&eacute;ter, el di&aacute;metro peque&ntilde;o de la mu&ntilde;eca, la hipotensi&oacute;n arterial, los estados hipercoagulables, el uso de vasopresores, la enfermedad autoinmune, la diabetes mellitus, el g&eacute;nero femenino, la edad mayor de 65 a&ntilde;os y el hematoma en el sitio de la punci&oacute;n<sup>3,8</sup>. Generalmente los cat&eacute;teres de tefl&oacute;n se han asociado con menor formaci&oacute;n de trombosis arterial que los de polipropileno<sup>9</sup>. En 1977 Bedford<sup>10</sup> encontr&oacute; una mayor proporci&oacute;n de trombosis arterial al usar cat&eacute;teres de 18 G que en los de 20 G (36 vs. 8%, respectivamente) y evidenci&oacute; una relaci&oacute;n directa entre la formaci&oacute;n de trombosis y el di&aacute;metro de la arteria (mayor para arterias menores de 2 mm de di&aacute;metro) y un mayor tiempo de recanalizaci&oacute;n en los vasos peque&ntilde;os. Este hallazgo se explica porque los cat&eacute;teres de 18 G ocupan mayor &aacute;rea transversal de los vasos que los de 20 G. El m&eacute;todo de punci&oacute;n (directa o transfixiante) no se ha visto asociado a un incremento del riesgo de trombosis, ni la recanalizaci&oacute;n de una arteria previamente canalizada aumenta la frecuencia de oclusi&oacute;n<sup>8</sup>. Por otro lado, los cat&eacute;teres arteriales de inserci&oacute;n a trav&eacute;s de gu&iacute;a con t&eacute;cnica de Seldinger modificada generaron la expectativa de permitir realizar el procedimiento con mayor tasa de &eacute;xito en comparaci&oacute;n con los convencionales, pero los estudios han demostrado que no hay diferencia en la misma ni en el tiempo de inserci&oacute;n, y adicionalmente no se han reportado diferencias en la incidencia de complicaciones isqu&eacute;micas<sup>11-13</sup>.</p>     <p>Las perfusiones a trav&eacute;s del cat&eacute;ter arterial son otra consideraci&oacute;n frente al riesgo de complicaciones. Aunque algunos estudios sobre el efecto de las perfusiones de heparina a dosis tales como 4U/ml han demostrado ser m&aacute;s eficaces que las perfusiones de soluci&oacute;n salina normal al 0,9% para mantener la permeabilidad de los cat&eacute;teres arteriales y disminuir la formaci&oacute;n de trombos hasta durante 96 h<sup>14</sup>, otras investigaciones con dosis menores —hasta de 1 U/ml de heparina— evidenciaron que no hab&iacute;a diferencia significativa en la duraci&oacute;n y la funcionalidad del cat&eacute;ter<sup>15</sup>. Adem&aacute;s se ha probado que aun con dosis bajas algunos pacientes pueden presentar alteraci&oacute;n del tiempo parcial de tromboplastina<sup>16</sup>.</p>     ]]></body>
<body><![CDATA[<p>Una nueva estrategia implementada para aumentar el &eacute;xito de la canalizaci&oacute;n de la arteria es la punci&oacute;n guiada por ultrasonograf&iacute;a, que permite determinar la presencia, la localizaci&oacute;n y la permeabilidad de la arteria. Un estudio en el que se compar&oacute; la t&eacute;cnica de canalizaci&oacute;n con ultrasonograf&iacute;a (US) versus la cl&aacute;sica con palpaci&oacute;n demostr&oacute; que la tasa de &eacute;xito en el primer intento fue mayor con US que con palpaci&oacute;n (62 vs. 34%), y adem&aacute;s el n&uacute;mero de intentos por paciente fue menor con US<sup>17</sup>. A pesar de estos hallazgos, no se recomienda el uso rutinario de la US para la inserci&oacute;n de cat&eacute;teres arteriales, y es considerada m&aacute;s efectiva como una t&eacute;cnica de rescate<sup>18</sup>.</p>     <p>Aunque las variantes anat&oacute;micas de la arteria radial han sido asociadas con la presentaci&oacute;n de complicaciones isqu&eacute;micas tras su canalizaci&oacute;n, se ha reportado que hasta el 30% de las personas pueden presentar estas variantes en su origen y trayecto, siendo menores en la parte distal donde es usualmente canalizada<sup>19</sup>. Adicionalmente diferentes estudios han mostrado la presencia del arco palmar superficial completo en m&aacute;s del 80% de las manos y el arco palmar profundo en el 90 al 95%<sup>20</sup>. Valentine y Modrall<sup>21</sup>, tras la revisi&oacute;n de los casos de isquemia secundaria a la canalizaci&oacute;n arterial a lo largo de 5 a&ntilde;os, encontraron que ninguno presentaba variantes anat&oacute;micas importantes, y el hallazgo com&uacute;n fue la presencia de trombosis arterial y vasoespasmo de la circulaci&oacute;n de la mano. El eco-doppler realizado a la paciente demostr&oacute; disminuci&oacute;n del calibre de la arteria radial sugiriendo vasoespasmo, raz&oacute;n por la cual el tratamiento se dirigi&oacute; hacia medidas que produjeran vasodilataci&oacute;n, como el bloqueo simp&aacute;tico del ganglio estrellado y el uso de calcioantagonistas. El tratamiento de las complicaciones isqu&eacute;micas de la canalizaci&oacute;n arterial es controvertido y generalmente debe ser individualizado, dado que la causa de la isquemia no es completamente clara. Aunque se ha postulado que la lesi&oacute;n local puede inducir trombosis y/o vasoespasmo con la consecuente disminuci&oacute;n del flujo, se esperar&iacute;a que la circulaci&oacute;n colateral lo compensara, de modo que se ha sugerido que un fen&oacute;meno emb&oacute;lico hacia la circulaci&oacute;n colateral o arterias digitales fuera el responsable de la isquemia distal y de las lesiones residuales cuando se interviene quir&uacute;rgicamente. Ante un paciente con esta complicaci&oacute;n se aconseja retirar el cat&eacute;ter y manejar con vasodilatadores y anticoagulaci&oacute;n en pacientes sintom&aacute;ticos con importante vasoespasmo y trombosis arterial, y en casos m&aacute;s severos, con disminuci&oacute;n del flujo e isquemia de la mano con trombectom&iacute;a y reparaci&oacute;n de la arteria radial<sup>9,10,22,23</sup>.</p>     <p>Desde de la primera descripci&oacute;n Peterson en 1949<sup>24</sup>, el uso de la canalizaci&oacute;n arterial para monitorizaci&oacute;n invasiva se ha extendido por el valor de la informaci&oacute;n que proporciona y por ser un procedimiento sencillo. Sin embargo, se ha generado una falsa sensaci&oacute;n de seguridad dada la escasa frecuencia de complicaciones. A lo largo del tiempo se han identificado algunos factores asociados con ellas y se han implementado intervenciones orientadas a prevenirlas, pero hasta el momento persisten controversias sobre su efectividad. Es necesario no pasar por alto que este procedimiento puede dejar secuelas permanentes y que el profesional que lo realice debe conocer todos los elementos que disminuyan las complicaciones de esta pr&aacute;ctica.</p>     <p><b>Fuente de financiaci&oacute;n</b></p>     <p>Recursos propios.</p>     <p><b>Conflicto de intereses</b></p>     <p>Ninguno declarado.</p>       <p><b><font size="3" face="Verdana">REFERENCIAS</font></b></p>      <!-- ref --><p>1. Mark JB, Slaughter TF. Cardiovascular monitoring. En: Miller RD, editor. Anesthesia. 6.a ed. Filadelfia: Churchill Livingstone Inc; 2005. p. 1272-4&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000041&pid=S0120-3347201200040000500001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>2. Bowdle TA. Complications of invasive monitoring. Anesthesiol Clin North America. 2002;20:571-88.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000042&pid=S0120-3347201200040000500002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>3. Scheer BV, Perel A, Pfeiffer UJ. Clinical Review: Complications and risk factor of peripheral arterial cathetes used for haemodynamic monitoring in anaesthesia and intensive care medicine. Critical Care. 2002;6:198-204.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000044&pid=S0120-3347201200040000500003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>4. Bedford RF, Wollman H. Comparison of percutaneous radial artery cannulation: an objective, prospective study in man. Anesthesiology. 1973;38:228-36.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000046&pid=S0120-3347201200040000500004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>5. Slogoff S, Keats AS, Arlund C. On the safety of radial artery cannulation. Anesthesiology. 1983;59:42-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000048&pid=S0120-3347201200040000500005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>6. Barone JE, Madlinger RV. Should an Allen test be performed before radial artery cannulation?. J Trauma. 2006;61:468-70.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000050&pid=S0120-3347201200040000500006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>7. Chowdhury UK, Airan B, Mishra PK, Kothari SS, Subramaniam GK, Ray R, et al. Histopathology and morphometry of radial artery conduits: basic study and clinical application. Ann Thorac Surg. 2004;78:1614-21.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000052&pid=S0120-3347201200040000500007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>8. Coulter TD, Wiedemann HP. Complications of hemodynamic monitoring. Clin Chest Med. 1999;20:2.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000054&pid=S0120-3347201200040000500008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>9. Bedford RF. Percutaneous radial artery cannulation increased safety using teflon catheters. Anesthesiology. 1975;42:219-22.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000056&pid=S0120-3347201200040000500009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>10. Bedford RF. Radial arterial function following percutaneouscannulation with 18 and 20 gauge catheters. Anesthesiology. 1977;47:37-9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000058&pid=S0120-3347201200040000500010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>11. Gerber DR, Zeifman CWE, Khouli HI, Dib H, Pratter MR. Comparison of wire-guided and nonwire-guided radial artery catheters. Chest. 1996;109:761-4.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000060&pid=S0120-3347201200040000500011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>12. Mangar D, Thrush DN, Connell GR, Downs JB. Direct or modified seldinger guide wire-directed for arterial catheter insertion. Anesth Analg. 1993;76:714-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000062&pid=S0120-3347201200040000500012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>13. Ohara Y, Nakayama S, Furukawa H, Satoh Y, Suzuki H, Yanai H. Use of a wire-guided cannula for radial arterial cannulation. J Anesth. 2007;21:83-5.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000064&pid=S0120-3347201200040000500013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>14. Randolph AG, Cook DJ, Gonzalez CA, Andrew M. Benefit of heparin in peripheral venous and arterial catheters: systematic review and meta-analysis of randomised controlled trials. BMJ. 1998;316:969-75.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000066&pid=S0120-3347201200040000500014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>15. Tuncali BE, Kuvaki B, Tuncali B, Capar E. A comparison of the efficacy of heparinized and nonheparinized solution for maintenance of perioperative radial arterial catheter patency and subsequent occlusion. Anesth Analg. 2005;100:1117-21.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000068&pid=S0120-3347201200040000500015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>16. del Cotillo M, Grane N, Llavor&eacute; M, Quintana S. Heparinized solution vs. saline solution in the maintenance of arterial catheters: a double blind randomized clinical trial. Intensive Care Med. 2008;34:339-43.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000070&pid=S0120-3347201200040000500016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>17. Levin PD, Sheinin O, Gozal Y. Use of ultrasound guidance in the insertion of radial artery catheters. Crit Care Med. 2003;31:481-4.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000072&pid=S0120-3347201200040000500017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>18. Troianos CA, Hartman GS, Glas KE, Skubas NJ, Eberhardt RT, Walker JD, et al. Guidelines for performing ultrasound guided vascular cannulation: recommendations of the American society of echocardiography and the society of cardiovascular anesthesiologists. Anesth Analg. 2012;114:46-72.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000074&pid=S0120-3347201200040000500018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>19. McCormack LJ, Cauldwell EW, Anson BJ. Brachial and antebrachial arterial patterns; a study of 750 extremities. Surg Gynecol Obstet. 1953;96:43-54.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000076&pid=S0120-3347201200040000500019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>20. Brzezinski M, Luisetti T, London MJ. Radial artery cannulation: a comprehensive review of recent anatomic and physiologic investigations. Anesth Analg. 2009;109:1763-81.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000078&pid=S0120-3347201200040000500020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>21. Valentine RJ, Modrall JG, Clagett GP. Hand ischemia after radial cannulation. J Am Coll Surg. 2005;201:18-22.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000080&pid=S0120-3347201200040000500021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>22. Steven G, Wallac H. Cannulation injury of the radial artery: diagnosis and treatment algorithm. Am J Crit Care. 2004;13:315-9.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000082&pid=S0120-3347201200040000500022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>23. Lee ML, Lee IO, Kong MH. Surgical treatment of digital ischemia occurred after radial artery catheterization. J Korean Med Sci. 2001;16:375-7.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000084&pid=S0120-3347201200040000500023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>24. Peterson LH, Dripps RD, Risman GC. A method for recording the arterial pressure pulse and blood pressure in man. Am Heart J. 1949;37:771-82.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000086&pid=S0120-3347201200040000500024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p> </font>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mark]]></surname>
<given-names><![CDATA[JB]]></given-names>
</name>
<name>
<surname><![CDATA[Slaughter]]></surname>
<given-names><![CDATA[TF]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Cardiovascular monitoring]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Miller]]></surname>
<given-names><![CDATA[RD]]></given-names>
</name>
</person-group>
<source><![CDATA[Anesthesia]]></source>
<year>2005</year>
<edition>6</edition>
<page-range>1272-4</page-range><publisher-loc><![CDATA[Filadelfia ]]></publisher-loc>
<publisher-name><![CDATA[Churchill Livingstone Inc]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bowdle]]></surname>
<given-names><![CDATA[TA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Complications of invasive monitoring]]></article-title>
<source><![CDATA[Anesthesiol Clin North America.]]></source>
<year>2002</year>
<volume>20</volume>
<page-range>571-88</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Scheer]]></surname>
<given-names><![CDATA[BV]]></given-names>
</name>
<name>
<surname><![CDATA[Perel]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Pfeiffer]]></surname>
<given-names><![CDATA[UJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Clinical Review: Complications and risk factor of peripheral arterial cathetes used for haemodynamic monitoring in anaesthesia and intensive care medicine]]></article-title>
<source><![CDATA[Critical Care.]]></source>
<year>2002</year>
<volume>6</volume>
<page-range>198-204</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bedford]]></surname>
<given-names><![CDATA[RF]]></given-names>
</name>
<name>
<surname><![CDATA[Wollman]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of percutaneous radial artery cannulation: an objective, prospective study in man]]></article-title>
<source><![CDATA[Anesthesiology.]]></source>
<year>1973</year>
<volume>38</volume>
<page-range>228-36</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Slogoff]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Keats]]></surname>
<given-names><![CDATA[AS]]></given-names>
</name>
<name>
<surname><![CDATA[Arlund]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[On the safety of radial artery cannulation]]></article-title>
<source><![CDATA[Anesthesiology.]]></source>
<year>1983</year>
<volume>59</volume>
<page-range>42-7</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Barone]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
<name>
<surname><![CDATA[Madlinger]]></surname>
<given-names><![CDATA[RV]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Should an Allen test be performed before radial artery cannulation?]]></article-title>
<source><![CDATA[J Trauma.]]></source>
<year>2006</year>
<volume>61</volume>
<page-range>468-70</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chowdhury]]></surname>
<given-names><![CDATA[UK]]></given-names>
</name>
<name>
<surname><![CDATA[Airan]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Mishra]]></surname>
<given-names><![CDATA[PK]]></given-names>
</name>
<name>
<surname><![CDATA[Kothari]]></surname>
<given-names><![CDATA[SS]]></given-names>
</name>
<name>
<surname><![CDATA[Subramaniam]]></surname>
<given-names><![CDATA[GK]]></given-names>
</name>
<name>
<surname><![CDATA[Ray]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Histopathology and morphometry of radial artery conduits: basic study and clinical application]]></article-title>
<source><![CDATA[Ann Thorac Surg.]]></source>
<year>2004</year>
<volume>78</volume>
<page-range>1614-21</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Coulter]]></surname>
<given-names><![CDATA[TD]]></given-names>
</name>
<name>
<surname><![CDATA[Wiedemann]]></surname>
<given-names><![CDATA[HP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Complications of hemodynamic monitoring]]></article-title>
<source><![CDATA[Clin Chest Med.]]></source>
<year>1999</year>
<volume>20</volume>
<page-range>2</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bedford]]></surname>
<given-names><![CDATA[RF]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Percutaneous radial artery cannulation increased safety using teflon catheters]]></article-title>
<source><![CDATA[Anesthesiology.]]></source>
<year>1975</year>
<volume>42</volume>
<page-range>219-22</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bedford]]></surname>
<given-names><![CDATA[RF]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Radial arterial function following percutaneouscannulation with 18 and 20 gauge catheters]]></article-title>
<source><![CDATA[Anesthesiology.]]></source>
<year>1977</year>
<volume>47</volume>
<page-range>37-9</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gerber]]></surname>
<given-names><![CDATA[DR]]></given-names>
</name>
<name>
<surname><![CDATA[Zeifman]]></surname>
<given-names><![CDATA[CWE]]></given-names>
</name>
<name>
<surname><![CDATA[Khouli]]></surname>
<given-names><![CDATA[HI]]></given-names>
</name>
<name>
<surname><![CDATA[Dib]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Pratter]]></surname>
<given-names><![CDATA[MR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of wire-guided and nonwire-guided radial artery catheters]]></article-title>
<source><![CDATA[Chest.]]></source>
<year>1996</year>
<volume>109</volume>
<page-range>761-4</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mangar]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Thrush]]></surname>
<given-names><![CDATA[DN]]></given-names>
</name>
<name>
<surname><![CDATA[Connell]]></surname>
<given-names><![CDATA[GR]]></given-names>
</name>
<name>
<surname><![CDATA[Downs]]></surname>
<given-names><![CDATA[JB]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Direct or modified seldinger guide wire-directed for arterial catheter insertion]]></article-title>
<source><![CDATA[Anesth Analg.]]></source>
<year>1993</year>
<volume>76</volume>
<page-range>714-7</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ohara]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Nakayama]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Furukawa]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Satoh]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Suzuki]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Yanai]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Use of a wire-guided cannula for radial arterial cannulation]]></article-title>
<source><![CDATA[J Anesth.]]></source>
<year>2007</year>
<volume>21</volume>
<page-range>83-5</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Randolph]]></surname>
<given-names><![CDATA[AG]]></given-names>
</name>
<name>
<surname><![CDATA[Cook]]></surname>
<given-names><![CDATA[DJ]]></given-names>
</name>
<name>
<surname><![CDATA[Gonzalez]]></surname>
<given-names><![CDATA[CA]]></given-names>
</name>
<name>
<surname><![CDATA[Andrew]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Benefit of heparin in peripheral venous and arterial catheters: systematic review and meta-analysis of randomised controlled trials]]></article-title>
<source><![CDATA[BMJ.]]></source>
<year>1998</year>
<volume>316</volume>
<page-range>969-75</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tuncali]]></surname>
<given-names><![CDATA[BE]]></given-names>
</name>
<name>
<surname><![CDATA[Kuvaki]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Tuncali]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Capar]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A comparison of the efficacy of heparinized and nonheparinized solution for maintenance of perioperative radial arterial catheter patency and subsequent occlusion]]></article-title>
<source><![CDATA[Anesth Analg.]]></source>
<year>2005</year>
<volume>100</volume>
<page-range>1117-21</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[del Cotillo]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Grane]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Llavoré]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Quintana]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Heparinized solution vs. saline solution in the maintenance of arterial catheters: a double blind randomized clinical trial]]></article-title>
<source><![CDATA[Intensive Care Med.]]></source>
<year>2008</year>
<volume>34</volume>
<page-range>339-43</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Levin]]></surname>
<given-names><![CDATA[PD]]></given-names>
</name>
<name>
<surname><![CDATA[Sheinin]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Gozal]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Use of ultrasound guidance in the insertion of radial artery catheters]]></article-title>
<source><![CDATA[Crit Care Med.]]></source>
<year>2003</year>
<volume>31</volume>
<page-range>481-4</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Troianos]]></surname>
<given-names><![CDATA[CA]]></given-names>
</name>
<name>
<surname><![CDATA[Hartman]]></surname>
<given-names><![CDATA[GS]]></given-names>
</name>
<name>
<surname><![CDATA[Glas]]></surname>
<given-names><![CDATA[KE]]></given-names>
</name>
<name>
<surname><![CDATA[Skubas]]></surname>
<given-names><![CDATA[NJ]]></given-names>
</name>
<name>
<surname><![CDATA[Eberhardt]]></surname>
<given-names><![CDATA[RT]]></given-names>
</name>
<name>
<surname><![CDATA[Walker]]></surname>
<given-names><![CDATA[JD]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Guidelines for performing ultrasound guided vascular cannulation: recommendations of the American society of echocardiography and the society of cardiovascular anesthesiologists]]></article-title>
<source><![CDATA[Anesth Analg.]]></source>
<year>2012</year>
<volume>114</volume>
<page-range>46-72</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[McCormack]]></surname>
<given-names><![CDATA[LJ]]></given-names>
</name>
<name>
<surname><![CDATA[Cauldwell]]></surname>
<given-names><![CDATA[EW]]></given-names>
</name>
<name>
<surname><![CDATA[Anson]]></surname>
<given-names><![CDATA[BJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Brachial and antebrachial arterial patterns; a study of 750 extremities]]></article-title>
<source><![CDATA[Surg Gynecol Obstet.]]></source>
<year>1953</year>
<volume>96</volume>
<page-range>43-54</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Brzezinski]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Luisetti]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[London]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Radial artery cannulation: a comprehensive review of recent anatomic and physiologic investigations]]></article-title>
<source><![CDATA[Anesth Analg.]]></source>
<year>2009</year>
<volume>109</volume>
<page-range>1763-81</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Valentine]]></surname>
<given-names><![CDATA[RJ]]></given-names>
</name>
<name>
<surname><![CDATA[Modrall]]></surname>
<given-names><![CDATA[JG]]></given-names>
</name>
<name>
<surname><![CDATA[Clagett]]></surname>
<given-names><![CDATA[GP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Hand ischemia after radial cannulation]]></article-title>
<source><![CDATA[J Am Coll Surg.]]></source>
<year>2005</year>
<volume>201</volume>
<page-range>18-22</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Steven]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Wallac]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cannulation injury of the radial artery: diagnosis and treatment algorithm]]></article-title>
<source><![CDATA[Am J Crit Care.]]></source>
<year>2004</year>
<volume>13</volume>
<page-range>315-9</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[ML]]></given-names>
</name>
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[IO]]></given-names>
</name>
<name>
<surname><![CDATA[Kong]]></surname>
<given-names><![CDATA[MH]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Surgical treatment of digital ischemia occurred after radial artery catheterization]]></article-title>
<source><![CDATA[J Korean Med Sci.]]></source>
<year>2001</year>
<volume>16</volume>
<page-range>375-7</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Peterson]]></surname>
<given-names><![CDATA[LH]]></given-names>
</name>
<name>
<surname><![CDATA[Dripps]]></surname>
<given-names><![CDATA[RD]]></given-names>
</name>
<name>
<surname><![CDATA[Risman]]></surname>
<given-names><![CDATA[GC]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A method for recording the arterial pressure pulse and blood pressure in man]]></article-title>
<source><![CDATA[Am Heart J.]]></source>
<year>1949</year>
<volume>37</volume>
<page-range>771-82</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
