<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0120-5609</journal-id>
<journal-title><![CDATA[Ingeniería e Investigación]]></journal-title>
<abbrev-journal-title><![CDATA[Ing. Investig.]]></abbrev-journal-title>
<issn>0120-5609</issn>
<publisher>
<publisher-name><![CDATA[Facultad de Ingeniería, Universidad Nacional de Colombia.]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0120-56092010000100013</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Influencia de la incorporación de lixiviados sobre la biodegradabilidad anaerobia de aguas residuales domésticas]]></article-title>
<article-title xml:lang="en"><![CDATA[The influence of incorporating leachate on anaerobic biodegradability of domestic sewage]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Barba]]></surname>
<given-names><![CDATA[Luz Edith]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Torres]]></surname>
<given-names><![CDATA[Patricia]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rodríguez Victoria]]></surname>
<given-names><![CDATA[Jenny Alexandra]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Marmolej]]></surname>
<given-names><![CDATA[Luís Fernando]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Pizarro]]></surname>
<given-names><![CDATA[Carlos Alexander]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad del Valle  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>Colombia</country>
</aff>
<pub-date pub-type="pub">
<day>01</day>
<month>04</month>
<year>2010</year>
</pub-date>
<pub-date pub-type="epub">
<day>01</day>
<month>04</month>
<year>2010</year>
</pub-date>
<volume>30</volume>
<numero>1</numero>
<fpage>75</fpage>
<lpage>79</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0120-56092010000100013&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0120-56092010000100013&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0120-56092010000100013&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[El tratamiento de los lixiviados constituye uno de los retos más importantes en el diseño y operación de rellenos sanitarios; la combinación de éstos con aguas residuales domésticas para su tratamiento mediante sistemas anaerobios constituye una opción con alto potencial de aplicación, principalmente en países en vía de desarrollo. Este trabajo presenta un estudio de la influencia de la incorporación de lixiviados generados en un relleno sanitario en el que se disponen residuos sólidos residenciales sobre la biodegradabilidad anaerobia de aguas residuales típicamente domésticas. Fueron estudiados cinco sustratos que correspondieron a agua residual doméstica y lixiviado, y tres mezclas de agua residual y lixiviado en proporciones de 10, 20 y 30% de lixiviado. El seguimiento de la biodegradabilidad se realizó durante 30 días mediante la medición de la producción acumulada de metano y la variación en la concentración y composición de los ácidos grasos volátiles (AGV); al final del ensayo se hizo el análisis de los componentes de la demanda química de oxígeno (DQO). Los resultados obtenidos indicaron que en las condiciones en que fue realizado el ensayo y para el tipo de lixiviado evaluado, la proporción máxima en volumen que puede ser degradada conjuntamente con agua residual doméstica por vía anaerobia sin que cause efectos inhibitorios significativos fue del 10%. Proporciones de lixiviados superiores presentaron comportamiento similar al del lixiviado, indicando potenciales efectos inhibitorios en el proceso anaerobio.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Treating leachate is one of the most important challenges in designing and operating a sanitary landfill. Anaerobic treatment u-sing a mixture of leachate and domestic sewage represents a suitable treatment option having good potential applicability in developing countries. The influence of adding leachate from a domestic sanitary landfill on the anaerobic biodegradability of domestic sewage has been evaluated in this paper. Five samples were evaluated for the study: 100% domestic sewage (DS), 100% leachate (L) and three leachate mixtures (L) with domestic sewage (DS) as follows: 10%(L):90%(DS), 20%(L):80%(DS) and 30%(L):70%(DS). The samples´ anaerobic biodegradability was monitored for 30 days using methane production accumulation and variation in volatile fatty acid (VFA) concentration and composition. A detailed analysis of chemical oxygen demand (COD) composition was performed at the end of the monitoring period. The results of the study showed that a 10%(L):90%(DS) mixture provided the maximum leachate (L) domestic sewage (DS) combination mixture which could be anaerobically biodegradable with no significantly inhibitory effects. Mixtures using a higher percentage of leachate showed significantly potential inhibition effects on the anaerobic biodegradation of domestic sewage.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[agua residual doméstica]]></kwd>
<kwd lng="es"><![CDATA[biodegradabilidad anaerobia]]></kwd>
<kwd lng="es"><![CDATA[inhibición]]></kwd>
<kwd lng="es"><![CDATA[lixiviado]]></kwd>
<kwd lng="en"><![CDATA[anaerobic biodegradability]]></kwd>
<kwd lng="en"><![CDATA[domestic sewage]]></kwd>
<kwd lng="en"><![CDATA[inhibition]]></kwd>
<kwd lng="en"><![CDATA[leachate]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  <font size = "2" face = "verdana">     <p>    <center><font size = "4"><b> Influencia de la incorporaci&oacute;n de lixiviados sobre la  biodegradabilidad anaerobia de aguas residuales dom&eacute;sticas</b></font></center></p>     <p>    <center><font size = "3"><b>The influence of incorporating  leachate on anaerobic biodegradability of domestic sewage</b></font></center></p>     <p><b> Luz Edith Barba<sup>1</sup>, Patricia Torres<sup>2</sup>, Jenny Alexandra Rodr&iacute;guez Victoria<sup>3</sup>, Lu&iacute;s Fernando Marmolejo<sup>4</sup>y Carlos Alexander Pizarro<sup>5</sup></b></p>     <p> <sup>1</sup>  Qu&iacute;mico. M.Sc., Universidad del Valle, Colombia. Profesora titular, Facultad de  Ingenier&iacute;a, Universidad del Valle, Colombia.<a href = "mailto:luebarba@univalle.edu.co"> luebarba@univalle.edu.co</a>  <sup>2</sup> Ingeniera sanitaria, Universidad del Valle, Colombia. M.Sc. y Ph.D.,  Universidad Sao Paulo, Brasil. Profesora asociada, Facultad de Ingenier&iacute;a,  Universidad del Valle, Colombia. <a href = "mailto:patoloz@univalle.edu.co">patoloz@univalle.edu.co</a> <sup>3</sup> Ingeniera  sanitaria, Universidad del Valle, Colombia. M.Sc. y Ph.D., Universidad Sao  Paulo, Brasil. Profesora asociada, Facultad de Ingenier&iacute;a, Universidad del  Valle, Colombia. <a href = "mailto:yennyrod@univalle.edu.co">yennyrod@univalle.edu.co</a> <sup>4</sup> Ingeniero sanitario, M.Sc., Universidad del Valle, Colombia. Candidato a Ph.D.,  en Ingenier&iacute;a &Aacute;rea de &Eacute;nfasis Ingenier&iacute;a Sanitaria y Ambiental. Profesor  asistente, Facultad de Ingenier&iacute;a, Universidad del Valle, Colombia. <a href = "mailto:lufermar@univalle.edu.co">lufermar@univalle.edu.co</a> <sup>5</sup>  Ingeniero  sanitario, Universidad del Valle, Colombia. Estudiante M.Sc.,en Ingenier&iacute;a &Aacute;rea  de &Eacute;nfasis Ingenier&iacute;a Sanitaria y Ambiental, Facultad de Ingenier&iacute;a,  Universidad del Valle, Colombia. <a href = "mailto:carpizar@univalle.edu.co">carpizar@univalle.edu.co</a> </p> <hr size = "1">     <p><b>RESUMEN</b></p>    <p>   El tratamiento de los lixiviados constituye uno de los  retos m&aacute;s importantes en el dise&ntilde;o y operaci&oacute;n de rellenos sanitarios; la  combinaci&oacute;n de &eacute;stos con aguas residuales dom&eacute;sticas para su tratamiento  mediante sistemas anaerobios constituye una opci&oacute;n con alto potencial de  aplicaci&oacute;n, principalmente en pa&iacute;ses en v&iacute;a de desarrollo. Este trabajo  presenta un estudio de la influencia de la incorporaci&oacute;n de lixiviados generados  en un relleno sanitario en el que se disponen residuos s&oacute;lidos residenciales  sobre la biodegradabilidad anaerobia de aguas residuales t&iacute;picamente  dom&eacute;sticas. Fueron estudiados cinco sustratos que correspondieron a agua  residual dom&eacute;stica y lixiviado, y tres mezclas de agua residual y lixiviado en  proporciones de 10, 20 y 30% de lixiviado. El seguimiento de la  biodegradabilidad se realiz&oacute; durante 30 d&iacute;as mediante la medici&oacute;n de la  producci&oacute;n acumulada de metano y la variaci&oacute;n en la concentraci&oacute;n y composici&oacute;n  de los &aacute;cidos grasos vol&aacute;tiles (AGV); al final del ensayo se hizo el an&aacute;lisis  de los componentes de la demanda qu&iacute;mica de ox&iacute;geno (DQO). Los resultados  obtenidos indicaron que en las condiciones en que fue realizado el ensayo y para el tipo de  lixiviado evaluado, la proporci&oacute;n m&aacute;xima en volumen que puede ser degradada  conjuntamente con agua residual dom&eacute;stica por v&iacute;a anaerobia sin que cause  efectos inhibitorios significativos fue del 10%. Proporciones de lixiviados superiores presentaron comportamiento similar  al del lixiviado, indicando potenciales efectos inhibitorios en el proceso  anaerobio.</p>     <p><b>Palabras clave</b>: agua residual  dom&eacute;stica, biodegradabilidad anaerobia, inhibici&oacute;n, lixiviado. </p> <hr size = "1">     ]]></body>
<body><![CDATA[<p><b>ABSTRACT </b></p>    <p>   Treating leachate is one of the most important  challenges in designing and operating a sanitary landfill. Anaerobic treatment  u-sing a mixture of leachate and domestic sewage represents a suitable  treatment option having good potential applicability in developing countries.  The influence of adding leachate from a domestic sanitary landfill on the  anaerobic biodegradability of domestic sewage has been evaluated in this paper.  Five samples were evaluated for the study: 100% domestic sewage (DS), 100%  leachate (L) and three leachate mixtures (L) with domestic sewage (DS) as  follows: 10%(L):90%(DS), 20%(L):80%(DS) and 30%(L):70%(DS). The samples  anaerobic biodegradability was monitored for 30 days using methane production  accumulation and variation in volatile fatty acid (VFA) concentration and  composition. A detailed analysis of chemical oxygen demand (COD) composition  was performed at the end of the monitoring period. The results of the study  showed that a 10%(L):90%(DS) mixture provided the maximum leachate (L) domestic  sewage (DS) combination mixture which could be anaerobically biodegradable with  no significantly inhibitory effects. Mixtures using a higher percentage of  leachate showed significantly potential inhibition effects on the anaerobic  biodegradation of domestic sewage. </p>     <p><b>Keywords:</b> anaerobic  biodegradability, domestic sewage, inhibition, leachate.</p>  <hr size = "1">     <p>Recibido: febrero  26 de 2009  Aceptado: marzo  1 de 2010</p>     <p><font size = "3"><b>Introducci&oacute;n</b></font></p>     <p>Uno de los problemas m&aacute;s importantes en el dise&ntilde;o y  mantenimiento de rellenos sanitarios es el manejo de los lixiviados genera-dos  por la percolaci&oacute;n del agua a trav&eacute;s del suelo, los cuales representan un  riesgo potencial para la salud de los ecosistemas y de la poblaci&oacute;n (Salem et  &aacute;l., 2008). El agua residual dom&eacute;stica &mdash;ARD&mdash; es un residuo l&iacute;quido que por su  alto contenido de materia org&aacute;nica biodegradable &mdash;alta relaci&oacute;n de demanda  bioqu&iacute;mica de ox&iacute;geno (DBO)5/DQO&mdash; y adecuado nivel de nutrientes (relaci&oacute;n DBO5:  N: P) puede ser tratada de una forma eficiente a trav&eacute;s de procesos biol&oacute;gicos  como los anaerobios, principalmente en pa&iacute;ses de clima tropical donde las  condiciones de temperatura (mayor a 20 &deg;C) son favorables para el adecuado  desarrollo de los procesos anaerobios (Speece, 1996; Foresti, 2002).</p>     <p>El  agua residual dom&eacute;stica &mdash;ARD&mdash; es un residuo l&iacute;quido que por su alto contenido  de materia org&aacute;nica biodegradable &mdash;alta relaci&oacute;n de demanda bioqu&iacute;mica de  ox&iacute;geno (DBO)5/DQO&mdash; y adecuado nivel de nutrientes (relaci&oacute;n DBO5:  N: P) puede ser tratada de una forma eficiente a trav&eacute;s de procesos biol&oacute;gicos  como los anaerobios, principalmente en pa&iacute;ses de clima tropical donde las  condiciones de temperatura (mayor a 20 &deg;C) son favorables para el adecuado  desarrollo de los procesos anaerobios (Speece, 1996; Foresti, 2002). </p>    <p>     La  incorporaci&oacute;n de lixiviados al tratamiento anaerobio de ARD viene siendo  utilizada en los &uacute;ltimos a&ntilde;os como una estrategia de manejo de lixiviados  debido principalmente a su sencillez y bajos costos operativos (Ahn <i>et &aacute;l</i>., 2002). Un argumento a favor del  tratamiento combinado de estos residuos es el aporte de nitr&oacute;geno en forma  amoniacal por parte del lixiviado y de f&oacute;sforo del ARD, lo que permite suprimir  o reducir la adici&oacute;n de nutrientes al sistema de tratamiento (Renou <i>et &aacute;l</i>., 2008); adicionalmente, se  disminuye el requerimiento de ajuste del pH dadas las caracter&iacute;sticas alcalinas  del lixiviado (Borzaconni <i>et &aacute;l</i>.,  1996; Torres <i>et &aacute;l</i>., 2005).</p>    <p>     Experiencias  como las reportadas por Facchin <i>et &aacute;l</i>.  (2000), Silva <i>et &aacute;l</i>. (2002), Tavares <i>et &aacute;l</i>. (2002) y Bohdziewicz <i>et  &aacute;l</i>. (2008) evidencian la potencialidad de  tratar en forma conjunta el ARD y los lixiviados en sistemas anaerobios; aunque  una estimativa de la producci&oacute;n de lixiviados y de aguas residuales dom&eacute;sticas  de una comunidad representa una relaci&oacute;n volum&eacute;trica de tan solo 1 a 2% de lixiviados, las  experiencias reportan porcentajes de lixiviado hasta del 20%, debido a que en  muchos lugares se encuentran grandes vol&uacute;menes almacenados en lagunas de  lixiviados. En algunos de esos estudios se observ&oacute; la reducci&oacute;n en la  eficiencia del tratamiento por problemas de inhibici&oacute;n causados por la  presencia en el lixiviado de metales pesados y compuestos org&aacute;nicos de baja  biodegradabilidad (Ce&ccedil;en y Aktas, 2004).</p>    <p>     Una forma de mitigar los posibles  efectos inhibitorios sobre el tratamiento anaerobio causados por el lixiviado  es la de determinar la cantidad m&aacute;xima a ser incorporada al ARD, lo cual puede  realizarse con estudios de tratabilidad a escala de laboratorio, entre los que  se incluye la biodegradabilidad anaerobia, que cuantifica la fracci&oacute;n m&aacute;xima de  materia org&aacute;nica que podr&aacute; ser transformada por digesti&oacute;n anaerobia durante un  determinado periodo de tiempo y en determinadas condiciones operacionales, en  comparaci&oacute;n con la fracci&oacute;n te&oacute;rica estequiom&eacute;tricamente convertida (Field,  1994; Rozzi <i>et &aacute;l</i>., 2004, citados por  Amaral <i>et &aacute;l</i>., 2008). Los ensayos de  biodegradabilidad anaerobia se basan en el seguimiento de la producci&oacute;n  acumulada de biog&aacute;s, particularmente el metano, o del acompa&ntilde;amiento de la  reducci&oacute;n en la concentraci&oacute;n del sustrato, tal como se observa en la <a href="#fig1">Figura 1</a>.  La mayor&iacute;a de los ensayos emplea m&eacute;todos volum&eacute;tricos o manom&eacute;tricos para el  monitoreo de la producci&oacute;n de metano y cromatograf&iacute;a para determinar la  composici&oacute;n del biog&aacute;s (Amaral <i>et &aacute;l</i>.,  2008). </p>         ]]></body>
<body><![CDATA[<p>           <center><a name="fig1">         <img src="img/revistas/iei/v30n1/1a13f01.jpg"></a>       </center>     </p>         <p>     Para determinar la cantidad m&aacute;xima de lixiviado que puede ser tratada  de manera conjunta con el ARD de forma que garantice una buena eficiencia en el  tratamiento anaerobio y minimice efectos inhibitorios, en este estudio se  evalu&oacute; la influencia de la incorporaci&oacute;n de lixiviados generados en un relleno  sanitario regional sobre la biodegradabilidad anaerobia de aguas residuales  t&iacute;pica-mente dom&eacute;sticas, evaluando diferentes proporciones de lixiviado a  incorporar al ARD (10, 20, 30 y 100%).</p>        <p><font size = "3"><b> Desarrollo experimental</b></font></p>        <p><b>In&oacute;culo </b></p>    <p>     El  in&oacute;culo fue obtenido del lodo proveniente de un reactor UASB que trata ARD, el  cual fue evaluado en t&eacute;rminos de la concentraci&oacute;n de s&oacute;lidos totales y  vol&aacute;tiles (APHA<i>,</i> 2005),  sedimentabilidad, estabilidad y actividad metanog&eacute;nica espec&iacute;fica &mdash;AME&mdash; (Field,  1994). Antes de iniciar los ensayos el in&oacute;culo fue sometido a un lavado con  agua destilada para eliminar residuos de materia org&aacute;nica. Las concentraciones  utilizadas para la realizaci&oacute;n de los ensayos correspondieron a 1,5 g SSV/L para sustratos  con valores de DQO menores de 4g/L, y para valores superiores se aument&oacute; la  cantidad sin exceder una relaci&oacute;n lodo: sustrato (L:S) de 1:2,7. </p>    <p><b>Sustrato</b></p>    <p>     Los  sustratos utilizados en el ensayo se relacionan en la <a href="#tab1">Tabla 1</a>. </p>         <p>           <center><a name="tab1">         <img src="img/revistas/iei/v30n1/1a13t01.jpg"></a>       </center>     </p>       ]]></body>
<body><![CDATA[<p>El lixiviado fue obtenido de un  relleno sanitario regional del departamento del Valle del Cauca que opera desde  hace diez a&ntilde;os y que recibe los residuos s&oacute;lidos dom&eacute;sticos de diecis&eacute;is  municipios. El sitio de toma de muestra fue seleccionado teniendo en cuenta que  fuera representativo de la generaci&oacute;n de lixiviados del relleno, el cual  present&oacute; una concentraci&oacute;n promedia de DQO de 6267 mg/L. El  ARD se tom&oacute; de la unidad de cribado de una planta de tratamiento de aguas  residuales dom&eacute;sticas en una zona t&iacute;picamente residencial de la ciudad de Cali,  con una concentraci&oacute;n promedia de DQO de 478 mg/L.</p>    <p>    Los  sustratos fueron caracterizados a trav&eacute;s de la determinaci&oacute;n de pH, DQO,  alcalinidad bicarbon&aacute;tica y total, NTK, N-NH<sub>4</sub>+ y  P total seg&uacute;n APHA(2005); los AGV  fueron medidos por cromatograf&iacute;a gaseosa seg&uacute;n Franco (2000).</p>      <p><b>Montaje del ensayo de biodegradabilidad anaerobia</b></p>      <p>Los  ensayos se llevaron a cabo en reactores de 1 L, en los que se adicion&oacute; el in&oacute;culo y el  respectivo sustrato. Se corrieron en forma paralela blancos de lodo sin  sustrato para corregir el aporte de metano por parte del lodo. En los ensayos no se adicionaron untrientes ni se  acondicion&oacute; el pH.&nbsp; La <a href="#fig2">Figura 2</a>  presenta el montaje b&aacute;sico del ensayo realizado con una temperatura controlada  de 30 &plusmn; 2 &deg;C;  cada uno de los sustratos y los blancos fueron evaluados por triplicado.</p>      <p>        <center><a name="fig2">      <img src="img/revistas/iei/v30n1/1a13f02.jpg" ></a>    </center>  </p>      <p><b>Seguimiento y control</b></p>      <p>     La  biodegradabilidad anaerobia se determin&oacute; mediante el monitoreo durante 30 d&iacute;as  de la producci&oacute;n acumulada de metano, el consumo diario del sustrato (DQO) y la  formaci&oacute;n de productos intermedios (composici&oacute;n de AGV) dos veces por semana.  La producci&oacute;n de metano se determin&oacute; por el m&eacute;todo volum&eacute;trico a trav&eacute;s del  sistema de desplazamiento de l&iacute;quido (NaOH 3%) siguiendo la metodolog&iacute;a  descrita por Field (1994).</p>    <p>     Para  calcular la fracci&oacute;n biodegradable en cada uno de los reactores, se convirti&oacute;  el volumen acumulado de metano en masa de DQO considerando que  estequiom&eacute;tricamente, a 30 oC, 1 g de DQO corresponde a 393 mL de metano, y se  dividi&oacute; ese valor por la masa incubada de DQO (Chernicharo, 2007). Al final del  ensayo se evaluaron los componentes de la DQO en cada uno de los sustratos.</p>         <p><font size = "3"><b>Resultados y discusi&oacute;n</b></font></p>         ]]></body>
<body><![CDATA[<p><b>Caracterizaci&oacute;n del in&oacute;culo y los sustratos</b></p>     <p>Los  resultados de la caracterizaci&oacute;n del in&oacute;culo se presentan en la <a href="#tab2">Tabla 2</a>.</p>     <p>       <center><a name="tab2">     <img src="img/revistas/iei/v30n1/1a13t02.jpg"></a>   </center> </p>      <p>Con base en los valores y referencias  reportados en la <a href="#tab2">Tabla 2</a>, y de acuerdo con la clasificaci&oacute;n de Field <i>et &aacute;l</i>. (1995), el lodo usado como  in&oacute;culo presenta caracter&iacute;sticas entre floculento y disperso, y adem&aacute;s cumple  con los requisitos y caracter&iacute;sticas m&iacute;nimas para tratamiento anaerobio (Field,  1994; Espitia <i>et &aacute;l</i>.<i>,</i> 1998) respecto de su contenido de ST,  STV, estabilidad y AME.</p>    <p>     En la   <a href="#tab3">Tabla 3</a>, donde se se&ntilde;alan las caracter&iacute;sticas de los  sustratos, se aprecia que en general &eacute;stos presentaron condiciones adecuadas  para su tratabilidad anaerobia, una vez que la predominancia de la alcalinidad en forma  bicarbon&aacute;tica en el lixiviado fue favorable para garantizar la capacidad de  tamp&oacute;n al sistema; adicionalmente, no se present&oacute; d&eacute;ficit de nutrientes ya que  la relaci&oacute;n DQO : N: P fue superior a 350:5:1, valor recomendado  para la o-peraci&oacute;n eficiente de reactores anaerobios (Chernicharo, 2007). Los valores de pH presentes en las mezclas con  lixiviados se hallan tambi&eacute;n en el rango establecido para la digesti&oacute;n  anaerobia (Field, 1994). A pesar de que el nitr&oacute;geno amoniacal present&oacute;  concentraciones cercanas a 1.500 mg/L, valor que seg&uacute;n Amaral <i>et &aacute;l.</i> (2008) puede causar efecto  inhibitorio al proceso anaerobio, Field (1994)  reporta que una  inhibici&oacute;n severa s&oacute;lo se presenta por encima de los 3.500 mg/L con un lodo  adaptado. </p>      <p>        <center><a name="tab3">      <img src="img/revistas/iei/v30n1/1a13t03.jpg"></a>    </center>  </p>      <p><b>Ensayos  de biodegradabilidad</b></p>        <p><b><i>AGV</i></b></p>    ]]></body>
<body><![CDATA[<p>     El seguimiento de la degradaci&oacute;n anaerobia a trav&eacute;s  del an&aacute;lisis de los AGV para los diferentes sustratos se muestra en la <a href="#fig3">Figura 3</a>. Se evidencia que el &aacute;cido ac&eacute;tico fue el predominante, seguido por el &aacute;cido  but&iacute;rico, lo que favoreci&oacute; la biodegradabilidad anaerobia del sustrato, ya que  la metanog&eacute;nesis acetocl&aacute;stica es la responsable de la mayor fracci&oacute;n de metano  producido a partir de la degradaci&oacute;n anaerobia de la materia  org&aacute;nica (Van Haandel y Lettinga, 1994). </p>        <p>          <center><a name="fig5">        <img src="img/revistas/iei/v30n1/1a13f05.jpg"></a>      </center>             <center><a name="fig6">        <img src="img/revistas/iei/v30n1/1a13f06.jpg"></a>      </center>           <center><a name="fig3">        <img src="img/revistas/iei/v30n1/1a13f03.jpg"></a>      </center>    </p>        <p>     La fase acidog&eacute;nica vari&oacute; en cada sustrato, siendo  m&aacute;s lenta a medida que aument&oacute; el porcentaje de lixiviado incorporado; mientras  que en el ARD la m&aacute;xima producci&oacute;n de AGV se present&oacute; el d&iacute;a 3 y una reducci&oacute;n  completa el d&iacute;a 12, en el lixiviado puro se alcanzaron los m&aacute;s altos niveles de  &aacute;cido ac&eacute;tico entre el d&iacute;a 12 y el d&iacute;a 15, y su m&aacute;xima reducci&oacute;n, que estuvo  alrededor del 30% del valor inicial, se obtuvo el d&iacute;a 30. Este comportamiento  indica que el ARD es un sustrato f&aacute;cilmente acidificable y que ocurri&oacute; un  efecto inhibitorio gradual por la incorporaci&oacute;n del lixiviado.</p>         <p><b><i>           <center>       Biodegradabilidad       </center>     </i></b></p>    <p>     La <a href="#fig4">Figura 4</a> muestra la composici&oacute;n de la DQO de los diferentes  sustratos al final del ensayo, donde se puede observar la biodegradabilidad  total o DQO biodegradable que est&aacute; constituida por la transformada en  crecimiento celular (Cel) y metano (M) y la fracci&oacute;n de AGV no degradada (AGV).  La DQO  biodegradable representa la DQO  reducida.</p>         <p>           ]]></body>
<body><![CDATA[<center><a name="fig4">         <img src="img/revistas/iei/v30n1/1a13f04.jpg"></a>       </center>     </p>         <p>     En el ARD el 85% de la materia org&aacute;nica fue  biodegradable y completamente transformada a metano, lo cual es un  comportamiento t&iacute;pico de sustratos f&aacute;cilmente acidificables (Chernicharo,  2007); el 15% restante represent&oacute; la materia org&aacute;nica resistente a la  degradaci&oacute;n anaerobia.</p>    <p>     En el lixiviado puro se obtuvo una biodegradabilidad  del 46%, del que apenas el 13% correspondi&oacute; a la fracci&oacute;n transformada a  metano, mostrando efectos inhibitorios sobre la etapa metanog&eacute;nica causados por la  posible presencia en el lixiviado de compuestos org&aacute;nicos de baja  biodegradabilidad, como lo reportan Ce&ccedil;en y Aktas (2004). </p>    <p>     La  biodegradabilidad anaerobia obtenida fue similar a la alcanzada por Berrueta <i>et &aacute;l</i>. (1996), oscilando entre 40 y 50%.  Otros autores (Torres <i>et &aacute;l</i>., 1997;  Santos <i>et &aacute;l</i>., 2004; Collazos y  G&oacute;mez, 2006 y Amaral <i>et &aacute;l</i>., 2008)  reportan valores hasta del 93%; estas diferencias est&aacute;n asociadas tanto a las  caracter&iacute;sticas del lixiviado (origen, edad, etc.) como a las condiciones en  las cuales se realiza el ensayo de biodegradabilidad anaerobia (cantidad y  calidad de in&oacute;culo, relaci&oacute;n lodo-sustrato, tiempo del ensayo, etc&eacute;tera).</p>    <p>     En los sustratos con mezclas de ARD y lixiviados se  ve que, a medida que el porcentaje en volumen del lixiviado se incrementa,  ocurre un aumento de la DQO  resistente, alcanzando valores de 27, 47 y 51% para los porcentajes de 10, 20 y  30% de lixiviado, respectivamente. Valores por encima del 20% fueron similares  al hallado para el lixiviado puro (54%), indicando que para porcentajes iguales  o superiores al 20% la inhibici&oacute;n es significativa y tan compleja como la degradaci&oacute;n  del lixiviado puro. En t&eacute;rminos ge-nerales, la DQO resistente se asocia a la presencia de  sustratoscomplejos que no son degradados debido a que la biomasa anaerobia aun  no se encuentra adaptada, o a la presencia de compuestos biol&oacute;gicamente inertes  (Field, 1994). Autores como Renou <i>et &aacute;l</i>.  (2008) mencionan que estas proporciones pueden ser  mayores cuando se efect&uacute;a un  pretratamiento al lixiviado como la adsorci&oacute;n con carb&oacute;n activado. </p>     <p><font size = "3"><b> Conclusiones</b></font></p>    <p>     La  incorporaci&oacute;n de lixiviado al ARD caus&oacute; un retardo en el desarrollo de la etapa  acidog&eacute;nica y un desequilibrio  entre &eacute;sta y la etapa metanog&eacute;nica del proceso  de biodegradaci&oacute;n anaerobia, lo que se tradujo en una acumulaci&oacute;n de los AGV.  Este efecto fue m&aacute;s notorio en la medida en que se increment&oacute; el porcentaje en  volumen de lixiviado.</p>    <p>     En las condiciones del ensayo y para el tipo de  lixiviado evaluado, se encontr&oacute; que la proporci&oacute;n m&aacute;xima en volumen que puede  ser degradada anaer&oacute;bicamente conjuntamente con agua residual dom&eacute;stica y sin  causar efectos inhibitorios significativos, es del 10%, pues a valores mayores  se incrementa el porcentaje de DQO resistente.</p>    <p>     Se recomienda usar los ensayos de  biodegradabilidad anaerobia para definir previamente y en cada caso en  particular (tipo y caracter&iacute;sticas de lixiviado, agua residual e in&oacute;culo  disponible) la fracci&oacute;n m&aacute;xima de lixiviado que puede ser incorporada a un  sistema de tratamiento anaerobio de aguas residuales dom&eacute;sticas, sin generar  problemas de inhibici&oacute;n que comprometan el desempe&ntilde;o y eficiencia de &eacute;ste.</p>         <p><font size = "3"><b>Bibliograf&iacute;a </b></font></p>    ]]></body>
<body><![CDATA[<!-- ref --><p>     Ahn, W. Y., Kang, M. S.,  Yim, S. K. Choi, K. H., Advanced Landfill Leachate Treatment Using Integrated  Membrane Process., Desalination, Vol. 149, 2002, pp. 109-114.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000073&pid=S0120-5609201000010001300001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>     Amaral, M., Ferreira, C.,  Lange, L., Aquino, S., Avaliacao da Biodegrabilidade Anaer&oacute;bia de Lixiviados de  Aterrro Sanit&aacute;rio., Revista Engenharia Sanit&aacute;ria e Ambiental, Vol.13, No. 1,  2008, pp. 38 -45.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000074&pid=S0120-5609201000010001300002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>     American Public Health  Association (APHA)., Standard Methods for the Examination of Water and Wastewater, 20th  edition, Washington D.C.,   USA, 2005 &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000075&pid=S0120-5609201000010001300003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>     Berrueta, J., Guti&eacute;rrez, A.,  Fueyo, G., Anaerobic Treatment of Leachates in Pilot-Scale UASB: Strategy of  Star-Up., Journal of Chemical Technology and Biotechnology,Vol. 67, No. 3, 1996, pp. 302-314.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000076&pid=S0120-5609201000010001300004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>     Bohdziewicz, J., Neczaj, E.,  Kwarciakreuse, A., Landfill Leachate Treatment by Means of Anaerobic Membrane  Bireactor., Desalination, Vol. 221, 2008, pp. 559-565.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000077&pid=S0120-5609201000010001300005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>     Borzacconi, L., Lopez, I., Ohanian, M., &amp; Vi&ntilde;as,  M., Degradaci&oacute;n Anaerobia de Lixiviado de Relleno Sanitario y Postratamiento  Aerobio., Memorias del IV Seminario-Taller Latinoamericano de Tratamiento  Anaerobio de Aguas Residuales, Bucaramanga, Colombia, Universidad Industrial de  Santander, 1996, pp. 569-578.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000078&pid=S0120-5609201000010001300006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>     Ce&ccedil;en, F., Aktas, O.,  Aerobic Co-Treatment of Landfill Leachate with Domestic Wastewater.,  Environmental Engineering Science, Vol. 21, No. 3, 2004, pp. 303-312.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000079&pid=S0120-5609201000010001300007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>     Chernicharo, C. A.,  Princ&iacute;pios Do Tratamiento Biol&oacute;gico de &Aacute;guas Residu&aacute;rias., Reatores Anaer&oacute;bios,  Vol. 5, UFMG (ed.), Brasil, 2007, pp. 379.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000080&pid=S0120-5609201000010001300008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>     Collazos, C. J., G&oacute;mez, L., Biodegradabilidad  Anaerobia del Lixiviado del Relleno Sanitario Do&ntilde;a Juana., Memorias del IX  Seminario Internacional de Medio Ambiente y Desarrollo Sostenible, Universidad  Industrial de Santander, Bucaramanga, Colombia,&nbsp;  2006, pp. 123-134.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000081&pid=S0120-5609201000010001300009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>     Espitia, S., Vargas, C., Diaz-Baez, M.,  Caracterizaci&oacute;n Fisicoqu&iacute;-mica y Microbiol&oacute;gica de Lodos Utilizados en Plantas  de Tratamiento Anaerobio., Memorias del V Taller y Seminario Latinoamericano  Tratamiento Anaerobio de Aguas Residuales, Vi&ntilde;a del Mar, Chile, Universidad Cat&oacute;lica  de Valpara&iacute;so -Universidad T&eacute;cnica Federico Santa Mar&iacute;a, 1998.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000082&pid=S0120-5609201000010001300010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>     Facchin, J., Colombo, M., da  Silva, S., Reichert, G., Avalia&ccedil;&atilde;o do Tratamento Combinado de Esgoto e  Lixiviado de Aterro Sanit&aacute;rio na Ete Lami (Porto Alegre) ap&oacute;s o Primeiro Ano de  Opera&ccedil;&atilde;o., Memorias del XXVII Congresso Interamericano de Engenharia Sanit&aacute;ria  e Ambiental, Porto Alegre, Brasil, Associa&ccedil;&atilde;o Brasileira de Engenharia  Sanit&aacute;ria e Ambiental, 2000, pp. 1-11.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000083&pid=S0120-5609201000010001300011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>     Field, J., Medici&oacute;n de Par&aacute;metros, Manual de Arranque y Operaci&oacute;n de Sistemas  de Flujo Ascendente con Manto de Lodo - UASB., Universidad del Valle, CVC,  Universidad Agr&iacute;cola de Wageningen, Colombia, 1994. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000084&pid=S0120-5609201000010001300012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>Field, J., Sierra, R., Lettinga, G., Effect  Wastewater Characteristics and Environmental Factors., Curso Internacional de  Tratamiento Anaerobio de Aguas Residuales, Universidad de Wageningen, Holanda, 1995.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000085&pid=S0120-5609201000010001300013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>     Foresti, E., Anaerobic  Treatment of Domestic Sewage: Stablished Technologies and Perspectives., Water  Science and Technology, Vol. 45, No. 10, 2002, pp. 181-186.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000086&pid=S0120-5609201000010001300014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>     Franco, D. F., Estudio de  las Metodolog&iacute;as Anal&iacute;ticas para la Determinaci&oacute;n de las Caracter&iacute;sticas  Fisicoqu&iacute;micas de Lodos Anaerobios y Sustrato.,&nbsp;  Tesis presentada a la   Universidad del Valle, para optar al grado de Qu&iacute;mico, 2000.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000087&pid=S0120-5609201000010001300015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>     van Haandel, A., Lettinga,  G., Anaerobic sewage treatment: A Practical Guide for Regions with a Hot  Climate., John Wiley &amp; Sons Ltd (ed.), Chichester, England,  1994, pp. 226.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000088&pid=S0120-5609201000010001300016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>     Renou, S., Givaudan, J.,  Poulain, S., Dirassouyan, F., Moulin, P., Landfill Leachate Treatment: Review and  Opportunity., Journal of Hazardous Materials, Vol. 150, 2008, pp. 468-493. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000089&pid=S0120-5609201000010001300017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>     Salem, Z., Hamouri, K., Djemaa, R., Allia. K., Evaluation  of Landfill Leachate Pollution and Treatment., Desalination, Vol. 220, 2008,  pp. 108-114. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000090&pid=S0120-5609201000010001300018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>     Santos, A., Kato, M., Florencio,  L., Estudo Comparativo Entre a Biodegradabilidade Aer&oacute;bia e Anaer&oacute;bia de  Chorume de Aterro Controlado., Memorias del XI SILUBESA - Simp&oacute;sio LusoBrasileiro  de Engenharia Sanit&aacute;ria e Ambiental, Natal, Brasil, 2004. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000091&pid=S0120-5609201000010001300019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>     Silva, M., Duarte, V.,  Prasad, S., Silva W., Barbosa, G., Tratamento Biol&oacute;gico Conjugado de Percolado  e Esgoto Sanit&aacute;rio em   Reator UASB., Memorias del VI Simp&oacute;sio &Iacute;talo Brasileiro de  Engenharia Sanit&aacute;ria e Ambiental, Vit&oacute;ria, Brasil, 2002.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000092&pid=S0120-5609201000010001300020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>     Speece, R., Anaerobic  Biotechnology for the Industrial Wastewaters., Archae Press (Ed.), Vanderbilt University, Tennessee, USA,  1996, pp. 394.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000093&pid=S0120-5609201000010001300021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>     Tavares, J., Duarte, V.,  Silva, W., Dantas, F., Barbosa, G., Batista, J., Avalia&ccedil;&atilde;o de Par&acirc;metros  Operacionais UASB Tratando L&iacute;quido Percolado Conjuntamente Esgotos Dom&eacute;sticos.,  Memorias del VI Simp&oacute;sio &Iacute;talo Brasileiro de Engenharia Sanit&aacute;ria e Ambiental,  Vit&oacute;ria, Brasil, 2002. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000094&pid=S0120-5609201000010001300022&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>     Torres,  P., Barba, L., Riascos, J., Vidal, J., Tratabilidade biol&oacute;gica de chorume  produzido em aterro nao controlado, Engenharia Sanit&aacute;ria e Ambiental, Vol. 2,  No. 2, 1997, pp. 55-62.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000095&pid=S0120-5609201000010001300023&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p>     Torres, P., Rodr&iacute;guez, J., Barba, L., Moran, A.,  Narv&aacute;ez, J., Tratamiento Anaerobio de Lixiviados en Reactores UASB., Revista  Ingenier&iacute;a y Desarrollo, No. 18, 2005, pp. 50-60. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000096&pid=S0120-5609201000010001300024&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --> ]]></body><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ahn]]></surname>
<given-names><![CDATA[W. Y]]></given-names>
</name>
<name>
<surname><![CDATA[Kang]]></surname>
<given-names><![CDATA[M. S]]></given-names>
</name>
<name>
<surname><![CDATA[Yim]]></surname>
<given-names><![CDATA[S. K]]></given-names>
</name>
<name>
<surname><![CDATA[Choi]]></surname>
<given-names><![CDATA[K. H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Advanced Landfill Leachate Treatment Using Integrated Membrane Process]]></article-title>
<source><![CDATA[Desalination]]></source>
<year>2002</year>
<volume>149</volume>
<page-range>109-114</page-range></nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Amaral]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Ferreira]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Lange]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Aquino]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="pt"><![CDATA[Avaliacao da Biodegrabilidade Anaeróbia de Lixiviados de Aterrro Sanitário]]></article-title>
<source><![CDATA[Revista Engenharia Sanitária e Ambiental]]></source>
<year>2008</year>
<volume>13</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>38 -45</page-range></nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="">
<collab>American Public Health Association</collab>
<source><![CDATA[Standard Methods for the Examination of Water and Wastewater]]></source>
<year>2005</year>
<edition>20th edition</edition>
<publisher-loc><![CDATA[Washington D.C ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Berrueta]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Gutiérrez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Fueyo]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Anaerobic Treatment of Leachates in Pilot-Scale UASB: Strategy of Star-Up]]></article-title>
<source><![CDATA[Journal of Chemical Technology and Biotechnology]]></source>
<year>1996</year>
<volume>67</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>302-314</page-range></nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bohdziewicz]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Neczaj]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Kwarciakreuse]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Landfill Leachate Treatment by Means of Anaerobic Membrane Bireactor]]></article-title>
<source><![CDATA[Desalination]]></source>
<year>2008</year>
<volume>221</volume>
<page-range>559-565</page-range></nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Borzacconi]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Lopez]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Ohanian]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Viñas]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<source><![CDATA[Degradación Anaerobia de Lixiviado de Relleno Sanitario y Postratamiento Aerobio]]></source>
<year></year>
<conf-name><![CDATA[ Memorias del IV Seminario-Taller Latinoamericano de Tratamiento Anaerobio de Aguas Residuales]]></conf-name>
<conf-date>1996</conf-date>
<conf-loc>Bucaramanga </conf-loc>
<page-range>569-578</page-range></nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ceçen]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Aktas]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Aerobic Co-Treatment of Landfill Leachate with Domestic Wastewater]]></article-title>
<source><![CDATA[Environmental Engineering Science]]></source>
<year>2004</year>
<volume>21</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>303-312</page-range></nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chernicharo]]></surname>
<given-names><![CDATA[C. A]]></given-names>
</name>
</person-group>
<article-title xml:lang="pt"><![CDATA[Princípios Do Tratamiento Biológico de Águas Residuárias]]></article-title>
<source><![CDATA[Reatores Anaeróbios]]></source>
<year>2007</year>
<volume>5</volume>
<page-range>379</page-range><publisher-name><![CDATA[UFMG]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Collazos]]></surname>
<given-names><![CDATA[C. J]]></given-names>
</name>
<name>
<surname><![CDATA[Gómez]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<source><![CDATA[Biodegradabilidad Anaerobia del Lixiviado del Relleno Sanitario Doña Juana]]></source>
<year></year>
<conf-name><![CDATA[ Memorias del IX Seminario Internacional de Medio Ambiente y Desarrollo Sostenible]]></conf-name>
<conf-date>2006</conf-date>
<conf-loc>Bucaramanga </conf-loc>
<page-range>123-134</page-range></nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Espitia]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Vargas]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Diaz-Baez]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<source><![CDATA[Caracterización Fisicoquí-mica y Microbiológica de Lodos Utilizados en Plantas de Tratamiento Anaerobio]]></source>
<year></year>
<conf-name><![CDATA[ V Taller y Seminario Latinoamericano Tratamiento Anaerobio de Aguas Residuales]]></conf-name>
<conf-date>1998</conf-date>
<conf-loc>Viña del Mar </conf-loc>
</nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Facchin]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Colombo]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[da Silva]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Reichert]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<source><![CDATA[Avaliação do Tratamento Combinado de Esgoto e Lixiviado de Aterro Sanitário na Ete Lami (Porto Alegre) após o Primeiro Ano de Operação]]></source>
<year></year>
<conf-name><![CDATA[ XXVII Congresso Interamericano de Engenharia Sanitária e Ambiental]]></conf-name>
<conf-date>2000</conf-date>
<conf-loc>Porto Alegre </conf-loc>
<page-range>1-11</page-range></nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Field]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[Medición de Parámetros, Manual de Arranque y Operación de Sistemas de Flujo Ascendente con Manto de Lodo - UASB]]></source>
<year>1994</year>
<publisher-name><![CDATA[Universidad del Valle, CVC, Universidad Agrícola de Wageningen]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Field]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Sierra]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Lettinga]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<source><![CDATA[Effect Wastewater Characteristics and Environmental Factors]]></source>
<year>1995</year>
<conf-name><![CDATA[ Curso Internacional de Tratamiento Anaerobio de Aguas Residuales]]></conf-name>
<conf-loc> </conf-loc>
</nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Foresti]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Anaerobic Treatment of Domestic Sewage: Stablished Technologies and Perspectives]]></article-title>
<source><![CDATA[Water Science and Technology]]></source>
<year>2002</year>
<volume>45</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>181-186</page-range></nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Franco]]></surname>
<given-names><![CDATA[D. F]]></given-names>
</name>
</person-group>
<source><![CDATA[Estudio de las Metodologías Analíticas para la Determinación de las Características Fisicoquímicas de Lodos Anaerobios y Sustrato]]></source>
<year>2000</year>
</nlm-citation>
</ref>
<ref id="B16">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[van Haandel]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Lettinga]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<source><![CDATA[Anaerobic sewage treatment: A Practical Guide for Regions with a Hot Climate]]></source>
<year>1994</year>
<page-range>226</page-range><publisher-loc><![CDATA[Chichester ]]></publisher-loc>
<publisher-name><![CDATA[John Wiley & Sons Ltd]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B17">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Renou]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Givaudan]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Poulain]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Dirassouyan]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Moulin]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Landfill Leachate Treatment: Review and Opportunity]]></article-title>
<source><![CDATA[Journal of Hazardous Materials]]></source>
<year>2008</year>
<volume>150</volume>
<page-range>468-493</page-range></nlm-citation>
</ref>
<ref id="B18">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Salem]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Hamouri]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Djemaa]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Allia]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evaluation of Landfill Leachate Pollution and Treatment]]></article-title>
<source><![CDATA[Desalination]]></source>
<year>2008</year>
<volume>220</volume>
<page-range>108-114</page-range></nlm-citation>
</ref>
<ref id="B19">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Santos]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Kato]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Florencio]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<source><![CDATA[Estudo Comparativo Entre a Biodegradabilidade Aeróbia e Anaeróbia de Chorume de Aterro Controlado]]></source>
<year></year>
<conf-name><![CDATA[ XI SILUBESA - Simpósio LusoBrasileiro de Engenharia Sanitária e Ambiental]]></conf-name>
<conf-date>2004</conf-date>
<conf-loc>Natal </conf-loc>
</nlm-citation>
</ref>
<ref id="B20">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Silva]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Duarte]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Prasad]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Silva]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Barbosa]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<source><![CDATA[Tratamento Biológico Conjugado de Percolado e Esgoto Sanitário em Reator UASB]]></source>
<year></year>
<conf-name><![CDATA[ VI Simpósio Ítalo Brasileiro de Engenharia Sanitária e Ambiental]]></conf-name>
<conf-date>2002</conf-date>
<conf-loc>Vitória </conf-loc>
</nlm-citation>
</ref>
<ref id="B21">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Speece]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<source><![CDATA[Anaerobic Biotechnology for the Industrial Wastewaters]]></source>
<year>1996</year>
<page-range>394</page-range><publisher-loc><![CDATA[^eTennessee Tennessee]]></publisher-loc>
<publisher-name><![CDATA[Archae Press (Ed.), Vanderbilt University]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B22">
<nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tavares]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Duarte]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Silva]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Dantas]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Barbosa]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Batista]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[Avaliação de Parâmetros Operacionais UASB Tratando Líquido Percolado Conjuntamente Esgotos Domésticos.]]></source>
<year></year>
<conf-name><![CDATA[ VI Simpósio Ítalo Brasileiro de Engenharia Sanitária e Ambiental]]></conf-name>
<conf-date>2002</conf-date>
<conf-loc>Vitória </conf-loc>
</nlm-citation>
</ref>
<ref id="B23">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Torres]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Barba]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Riascos]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Vidal]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="pt"><![CDATA[Tratabilidade biológica de chorume produzido em aterro nao controlado]]></article-title>
<source><![CDATA[Engenharia Sanitária e Ambiental]]></source>
<year>1997</year>
<volume>2</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>55-62</page-range></nlm-citation>
</ref>
<ref id="B24">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Torres]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Rodríguez]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Barba]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Moran]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Narváez]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Tratamiento Anaerobio de Lixiviados en Reactores UASB]]></article-title>
<source><![CDATA[Revista Ingeniería y Desarrollo]]></source>
<year>2005</year>
<numero>18</numero>
<issue>18</issue>
<page-range>50-60</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
