<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0120-5609</journal-id>
<journal-title><![CDATA[Ingeniería e Investigación]]></journal-title>
<abbrev-journal-title><![CDATA[Ing. Investig.]]></abbrev-journal-title>
<issn>0120-5609</issn>
<publisher>
<publisher-name><![CDATA[Facultad de Ingeniería, Universidad Nacional de Colombia.]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0120-56092015000200009</article-id>
<article-id pub-id-type="doi">10.15446/ing.investig.v35n2.46258</article-id>
<title-group>
<article-title xml:lang="en"><![CDATA[Stability criteria and critical runway conditions of propylene glycol manufacture in a continuous stirred tank reactor]]></article-title>
<article-title xml:lang="es"><![CDATA[Criterios de estabilidad y condiciones críticas de runaway de la producción de propilenglicol en un reactor continuo de tanque agitado]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[López-Zamora]]></surname>
<given-names><![CDATA[S. M]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Dobrosz-Gómez]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Gómez-García]]></surname>
<given-names><![CDATA[M. Á]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad Nacional de Colombia  ]]></institution>
<addr-line><![CDATA[Manizales ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Grupo de Investigación en Procesos Reactivos Intensificados con Separación y Materiales Avanzados (PRISMA)  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>Colombia</country>
</aff>
<aff id="A03">
<institution><![CDATA[,Grupo de Investigación en Procesos Reactivos Intensificados con Separación y Materiales Avanzados (PRISMA)  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>Colombia</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>05</month>
<year>2015</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>05</month>
<year>2015</year>
</pub-date>
<volume>35</volume>
<numero>2</numero>
<fpage>56</fpage>
<lpage>60</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_arttext&amp;pid=S0120-56092015000200009&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_abstract&amp;pid=S0120-56092015000200009&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://www.scielo.org.co/scielo.php?script=sci_pdf&amp;pid=S0120-56092015000200009&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="en"><p><![CDATA[The present paper presents the development of a new method for the analysis of the steady state and the safety operational conditions of the propylene oxide hydrolysis with excess of water in a Continuous Stirred Tank Reactor (CSTR). At first, for the industrial operational typical values, the generated and removed heat balances were examined. Next, the effect of coolant fluid temperature on the critical ignition and extinction temperatures (T CI and T CE, respectively) was analyzed. The influence of the heat exchange parameter (hS) on coolant and critical temperatures was also studied. Finally, the steady state operation areas were defined. The existence of multiple stable states was recognized when the heat exchange parameter was in the range of 6.636 < hS kJ/(min.K) < 11.125. The Unstable operation area was located between the T C&#124; and T CE values, restricting the reactor operation area to the low stable temperatures.]]></p></abstract>
<abstract abstract-type="short" xml:lang="es"><p><![CDATA[En este trabajo se presenta un nuevo método para el análisis del estado estable y de las condiciones operativas seguras para la hidrólisis del óxido de propileno con exceso de agua en un reactor continuo de tanque agitado (CSTR). Inicialmente, para valores típicos de operación industrial, se examinaron los balances de calor generado y removido. Luego, se analizó el efecto de la temperatura del fluido de enfriamiento en las temperaturas de ignición y extinción (T C&#124; y T CE, respectivamente). También se estudió el efecto del parámetro de transferencia de calor (hS) sobre las temperaturas críticas y del fluido de enfriamiento. Finalmente, se definieron las áreas de operación estables. Se reconoció la existencia de múltiples estados estables cuando el parámetro de transferencia de calor está en el intervalo de 6.636 < hS kJ/(min.K) < 11.125. El área de operación inestable está localizada entre los valores de TCI y TCE, restringiendo la operación del reactor al área de bajas temperaturas estables.]]></p></abstract>
<kwd-group>
<kwd lng="en"><![CDATA[Stability criteria]]></kwd>
<kwd lng="en"><![CDATA[propylene oxide]]></kwd>
<kwd lng="en"><![CDATA[propylene glycol]]></kwd>
<kwd lng="en"><![CDATA[runaway conditions]]></kwd>
<kwd lng="es"><![CDATA[Criterios de estabilidad]]></kwd>
<kwd lng="es"><![CDATA[óxido de propileno]]></kwd>
<kwd lng="es"><![CDATA[propilen glicol]]></kwd>
<kwd lng="es"><![CDATA[condiciones de runaway]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  <font size="2" face="Verdana">      <p>DOI: <a href="http://dx.doi.org/10.15446/ing.investig.v35n2.46258" target="_blank">http://dx.doi.org/10.15446/ing.investig.v35n2.46258</a>.</p>     <p align="center"><font size="4"><b>Stability criteria and critical runway conditions of propylene glycol manufacture in a continuous stirred tank reactor</b></font></p>     <p align="center"><font size="3"><b>Criterios de estabilidad y condiciones cr&iacute;ticas de runaway de la producci&oacute;n de propilenglicol en un reactor continuo de tanque agitado</b></font></p>     <p>S. M. L&oacute;pez-Zamora<sup>1</sup>, I. Dobrosz-G&oacute;mez<sup>2</sup>, and M. &Aacute;. G&oacute;mez-Garc&iacute;a<sup>3</sup></p>     <p><sup>1</sup>&nbsp;Sandra Milena L&oacute;pez Zamora. Chemical Engineer, Universidad Nacional de Colombia, Manizales, Colombia. M.Sc. in Chemical Engineering. Affiliation: Universidad Nacional de Colombia, Manizales, Colombia. Grupo de Investigaci&oacute;n en Procesos Reactivos Intensificados con Separaci&oacute;n y Materiales Avanzados (PRISMA). E-mail: <a href="mailto:smlopezz@unal.edu.co">smlopezz@unal.edu.co</a>.    <br> <sup>2</sup>&nbsp;Isabel Dobrosz G&oacute;mez. Chemist, Lodz University of Technology, Lodz, Poland. M. Sc. Eng., Lodz University of Technology, Lodz, Poland. PhD., Lodz University of Technology, Lodz, Poland. Affiliation: Grupo de Investigaci&oacute;n en Procesos Reactivos Intensificados con Separaci&oacute;n y Materiales Avanzados (PRISMA ) Colombia. E-mail: <a href="mailto:idobrosz-gomez@unal.edu.co">idobrosz-gomez@unal.edu.co</a>.    <br> <sup>3</sup>&nbsp;Miguel &Aacute;ngel G&oacute;mez. Chemical Engineer, Universidad Nacional de Colombia, Manizales, Colombia. M.Sc. in Chemical Engineering, Universidad Nacional de Colombia, Bogot&aacute;, Colombia. PhD in Chemical Engineering, Universit&eacute; Louis Fasteur, Strasbourg I, France. Affiliation: Grupo de Investigaci&oacute;n en Procesos Reactivos Intensificados con Separaci&oacute;n y Materiales Avanzados (PRISMA) Colombia. E-mail: <a href="mailto:magomez@unal.edu.co">magomez@unal.edu.co</a>.</p>     <p><b>How to cite: </b>L&oacute;pez-Zamora, S. M., Dobrosz-G&oacute;mez, I., &amp; G&oacute;mez-Garc&iacute;a, M. &Aacute;. (2015). Stability criteria and critical runway conditions of propylene glycol manufacture in a continuous stirred tank reactor. <i>Ingenier&iacute;a e Investigaci&oacute;n, 35(2), </i>56-60. DOI: <a href="http://dx.doi.org/10.15446/ing.investig.v35n2.46258" target="_blank">http://dx.doi.org/10.15446/ing.investig.v35n2.46258</a>.</p> <hr>     <p><b>ABSTRACT</b></p>     ]]></body>
<body><![CDATA[<p>The present paper presents the development of a new method for the analysis of the steady state and the safety operational conditions of the propylene oxide hydrolysis with excess of water in a Continuous Stirred Tank Reactor (CSTR). At first, for the industrial operational typical values, the generated and removed heat balances were examined. Next, the effect of coolant fluid temperature on the critical ignition and extinction temperatures (T<sub>CI</sub> and T<sub>CE</sub>, respectively) was analyzed. The influence of the heat exchange parameter (hS) on coolant and critical temperatures was also studied. Finally, the steady state operation areas were defined. The existence of multiple stable states was recognized when the heat exchange parameter was in the range of 6.636 &lt; <i>hS </i>kJ/(min.K) &lt; 11.125. The Unstable operation area was located between the T<sub>C&#124;</sub> and T<sub>CE</sub> values, restricting the reactor operation area to the low stable temperatures.</p>     <p><b>Keywords: </b>Stability criteria, propylene oxide, propylene glycol, runaway conditions.</p> <hr>     <p> <b>RESUMEN</b></p>     <p>En este trabajo se presenta un nuevo m&eacute;todo para el an&aacute;lisis del estado estable y de las condiciones operativas seguras para la hidr&oacute;lisis del &oacute;xido de propileno con exceso de agua en un reactor continuo de tanque agitado (CSTR). Inicialmente, para valores t&iacute;picos de operaci&oacute;n industrial, se examinaron los balances de calor generado y removido. Luego, se analiz&oacute; el efecto de la temperatura del fluido de enfriamiento en las temperaturas de ignici&oacute;n y extinci&oacute;n (T<sub>C&#124;</sub> y T<sub>CE</sub>, respectivamente). Tambi&eacute;n se estudi&oacute; el efecto del par&aacute;metro de transferencia de calor (hS) sobre las temperaturas cr&iacute;ticas y del fluido de enfriamiento. Finalmente, se definieron las &aacute;reas de operaci&oacute;n estables. Se reconoci&oacute; la existencia de m&uacute;ltiples estados estables cuando el par&aacute;metro de transferencia de calor est&aacute; en el intervalo de 6.636 &lt; <i>hS </i>kJ/(min.K) &lt; 11.125. El &aacute;rea de operaci&oacute;n inestable est&aacute; localizada entre los valores de TCI y TCE, restringiendo la operaci&oacute;n del reactor al &aacute;rea de bajas temperaturas estables.</p>     <p><b>Palabras clave: </b>Criterios de estabilidad, &oacute;xido de propileno, propilen glicol, condiciones de <i>runaway.</i></p> <hr>     <p><b>Received: </b>October 15th 2014 <b>Accepted: </b>March 4th 2015</p> <hr>     <p><b>Introduction</b></p>     <p>Propylene glycol is an organic compound obtained by the hydrolysis of propylene oxide with excess of water. It is a colorless and odorless liquid. Nowadays it is produced on a large scale, and primarily used in the production of polymers (saturated polyester resins) and in the food processing (E-number E1520). Propylene glycol presents anti-freeze properties and it is used as fluid for heat transfer at low temperatures; as solvent in paints and cleaners; and as an intermediate for the synthesis of different chemical products such as alkyds (The Dow Chemical Company 2011).</p>     <p>The hydrolysis of propylene oxide with water is an exothermic reaction. Under certain conditions, it presents multiple steady states and/or runaway behavior, making the reactive operation potentially risky. For safety, it is very important to determine how stable the steady state is. Different methodologies for the safety operation of reactors and analysis of runaway conditions have been proposed. As a first approximation, thermal runaway prediction was performed by a lineal stability and overall energy balances analysis. It was established that critical conditions depend on the temperature curve. Thus, cooling in a chemical reactor can be controlled by thermal conduction in the reactive mixture (Semenov 1928; Kamenetskii 1969). More recently, the concept of parametric sensitivity analysis was proposed by Bilous &amp; Amundson (1956). They suggested that when the system operates in the parametric sensible area, slight changes in the inlet parameters of the reactor generate excessive changes in the outlet parameters. Thus, different criteria based on the geometric conditions of temperature and conversion curves have been developed. For the Continuous Stirred Tank Reactor (CSTR) systems some examples can be pointed out: (i) Luo <i>et al. </i>(2000) studied the polymerization of phenol-formaldehyde reaction and (ii) Ojeda <i>et al. </i>(2014) studied the cyclo-trimethylene-triamine production process.</p>     <p>In the case of propylene oxide hydrolysis, &Scaron;vandov&aacute; <i>et al. </i>(2005) discussed the relation between software tools, primarily designed for mathematical modeling and simulation, and chemical reactors analysis. They identified the Hazard and Operability (HAZOP) zone for the hydrolysis reaction. Additionally, Vadapalli &amp; Seader (2001) employed ASPEN Plus software for the study of multiple steady-states of this reaction, and Moln&aacute;r <i>et al. </i>(2003) presented the sensitivity analysis of a CSTR with cooling jacket.</p>     ]]></body>
<body><![CDATA[<p>In this work, a new method for the analysis of steady state and safety operational conditions of the hydrolysis of propylene oxide with excess of water is proposed. Thus, at first, the generated and removed heat balances are analyzed. Next, the effect of coolant fluid in the critical ignition and extinction temperatures is presented. The influence of the heat exchange parameter <i>(hS) </i>on coolant and critical temperatures is also studied. Finally, the steady state operation areas are defined.</p>     <p><b>Mathematical model</b></p>     <p>For the propylene oxide hydrolysis, Fogler (2008) reports a first order kinetic (n=1) with respect to propylene oxide and zero order one with respect to water Equations (<a href="#ec1">1</a>-<a href="#ec2">2</a>).</p>     <p align="center"><a name="ec1"><img src="img/revistas/iei/v35n2/v35n2a09ec1.jpg"></a></p>     <p align="center"><a name="ec2"><img src="img/revistas/iei/v35n2/v35n2a09ec2.jpg"></a></p>     <p>The overall energy balance in a CSTR implies that the heat generation rate <i>(Q<sub>G</sub>), </i>Equation (<a href="#ec3">3</a>), minus the heat removal rate (Q<sub>R</sub>), Equation (<a href="#ec4">4</a>), equals the heat accumulation (Equation(<a href="#ec5">5</a>)).</p>     <p align="center"><a name="ec3"><img src="img/revistas/iei/v35n2/v35n2a09ec3.jpg"></a></p>     <p align="center"><a name="ec4"><img src="img/revistas/iei/v35n2/v35n2a09ec4.jpg"></a></p>     <p align="center"><a name="ec5"><img src="img/revistas/iei/v35n2/v35n2a09ec5.jpg"></a></p>     <p>If the reactive system operates adiabatically, conversion and reactive temperature, for a time <i>t, </i>can be correlated by the ratio between the transient heat release (AH<sub>t</sub>) and the overall heat release (AH<sub>to</sub> <sub>l</sub>), as shown in Equation (<a href="#ec6">6</a>). Thus, the overall balance can be rewritten as follows (Equation(<a href="#ec7">7</a>)):</p>     ]]></body>
<body><![CDATA[<p align="center"><a name="ec6"><img src="img/revistas/iei/v35n2/v35n2a09ec6.jpg"></a></p>     <p align="center"><a name="ec7"><img src="img/revistas/iei/v35n2/v35n2a09ec7.jpg"></a></p>     <p>Uncontrolled reaction conditions (runaway) can occur when the heat generated in the process is higher than the removed one. In this case, the exothermic system goes through a quick increase in temperature (runaway condition). Semenov (1928) defined the sufficient, necessary, and critical runaway conditions as given by Equations (<a href="#ec8">8</a>) and (<a href="#ec9">9</a>).</p>     <p align="center"><a name="ec8"><img src="img/revistas/iei/v35n2/v35n2a09ec8.jpg"></a></p>     <p align="center"><a name="ec9"><img src="img/revistas/iei/v35n2/v35n2a09ec9.jpg"></a></p>     <p>Thus, considering steady state, from Equations (<a href="#ec7">7</a>) and (<a href="#ec9">9</a>), the critical temperature can be defined (Equation (<a href="#ec10">10</a>)), while the transition points, Equations (<a href="#ec11">11</a>)-(<a href="#ec13">13</a>), can be obtained by equaling the two roots of Equation (<a href="#ec10">10</a>). In fact, it presents two possible numerical solutions: the low one, which corresponds to the critical ignition temperature and the high one, which is the critical extinction temperature.</p>     <p align="center"><a name="ec10"><img src="img/revistas/iei/v35n2/v35n2a09ec10.jpg"></a></p>     <p align="center"><a name="ec11"><img src="img/revistas/iei/v35n2/v35n2a09ec11.jpg"></a></p>     <p align="center"><a name="ec12"><img src="img/revistas/iei/v35n2/v35n2a09ec12.jpg"></a></p>     <p align="center"><a name="ec13"><img src="img/revistas/iei/v35n2/v35n2a09ec13.jpg"></a></p>     ]]></body>
<body><![CDATA[<p>Thus, the analysis of the reactive system stability was performed based on the definitions presented above. Kinetic parameters and typical industrial operation conditions are given in <a href="#t1">Table 1</a>.</p>     <p align="center"><a name="t1"><img src="img/revistas/iei/v35n2/v35n2a09t1.jpg"></a></p>      <p><b>Results and discussion</b></p>     <p>The desirable operation conditions, defined from the transition point, the critical ignition and extinction temperatures, and the generated and removed heat curves are presented in <a href="#f1">Figure 1</a>. The Figure also includes the overall energy balance expressed as the removed heat (straight lines) and generated heat (Q<sub>c</sub>), at a coolant temperature of 288.15 K. As a reference, the feed temperature of the reactive mixture <i>(T<sub>feed</sub>) </i>and the vaporization temperature of propylene oxide <i>(T<sub>vap</sub></i>= 324.75 K) were indicated. It is important to notice that operation at temperatures higher than the vaporization one should be avoided.</p>     <p align="center"><a name="f1"><img src="img/revistas/iei/v35n2/v35n2a09f1.jpg"></a></p>      <p>Two tangent and two intersection points <i>(TCE, TCI, TSE, TSI) </i>can be defined from <a href="#f1">Figure 1</a>. They correspond to the critical <i>hS </i>slope values (<a href="#t2">Table 2</a>). Thus, unstable operation conditions will correspond to the values 6.636 &lt; <i>hS kJ/ (min.K) </i>&lt; 11.125. If the reactive system operates at these conditions, the existence of multiple steady states can be expected. In this region, three intersection points can be obtained: T<sub>S,L</sub>, <i>T<sub>S,M</sub></i> and <i>T<sub>S,H</sub></i>(<a href="#f1">Figure 1</a>).</p>     <p align="center"><a name="t2"><img src="img/revistas/iei/v35n2/v35n2a09t2.jpg"></a></p>     <p>For an intermediate <i>hS </i>value of 8.8807, the intersection points were calculated (dotted line). These values are included in <a href="#t3">Table 3</a> and compared with the results reported by Moln&aacute;r <i>et al. </i>(2003), obtained using a CSTR transient model. From the analysis of the <i>T<sub>SM</sub></i>value, one can see that a slight change in temperature can take the system into a higher (runaway) or lower operation temperature. Even if the higher operation state implies higher productivity, it is also related to a non-safety operation. Hence, operational values proposed by Moln&aacute;r <i>etal. </i>(2003) can be considered as stable ones, taking into consideration that: firstly, operation temperature is lower than the ignition critical point <i>(T<sub>S,L</sub>&lt;T</i><i><sub>Cl</sub>) </i>and secondly it is near the intersection ignition point (T<i><sub>S,H</sub></i>&sim;T<i><sub>Sl</sub></i>).</p>     <p align="center"><a name="t3"><img src="img/revistas/iei/v35n2/v35n2a09t3.jpg"></a></p>     <p><a href="#t2">Figure 2</a> presents the effect of coolant temperature on the intersection and tangent points <i>(T<sub>Cl</sub>, T<sub>CE</sub>, T<sub>SI</sub>, T<sub>SE</sub>). </i>Slight rise in coolant temperature results in an increase in <i>T<sub>SE</sub>, T<sub>SL</sub></i> and <i>T<sub>CI</sub></i> and in a decrease in <i>T<sub>CE</sub>, T<sub>SH</sub>, </i>and <i>T<sub>SI</sub>. </i>All lines converge to the transition point (<a href="#f2">Figure 2</a>). Reactive system should operate in the stable state area without surpassing vaporization temperature.</p>     ]]></body>
<body><![CDATA[<p align="center"><a name="f2"><img src="img/revistas/iei/v35n2/v35n2a09f2.jpg"></a></p>     <p>Thus, different operation areas can be defined:</p>    <blockquote>     <p>(i)&nbsp;A stable high temperature area (<i>T<sub>SH</sub></i>), limited by the final ignition temperature stable point <i>(T<sub>SI</sub>) </i>and extinction critical temperature <i>(T<sub>CE</sub>),</i></p>     <p>(ii)&nbsp;A stable low temperature area (<i>T<sub>SL</sub></i>), restricted by the final stable extinction temperature point and the critical ignition temperature <i>(T<sub>Cl</sub>);</i></p>     <p>(iii)&nbsp;An unstable area between critical extinction (<i>T<sub>CE</sub></i>) and ignition temperatures <i>(T<sub>Cl</sub>); </i>and</p>     <p>(iv)&nbsp;A stable area external to the final extinction (<i>T<sub>SE</sub></i>) and ignition temperature points <i>(T<sub>SI</sub>).</i></p></blockquote>     <p>In order to avoid non-safety or non-controlled conditions, the reactive system should operate in the (iv) area.</p>     <p><a href="#f3">Figure 3</a> displays the effect of coolant temperature on the slope of removed heat (hS). Maximum <i>hS </i>value corresponds to the transition point <i>(hS<sub>tr</sub>=16.74 kJ/(min.K)). </i>This is a watershed of temperature: it increases as propylene oxide fraction increases (see inserted figure in <a href="#f3">Figure 3</a>). The value of <i>hS </i>increases as the T  increases. When <i>T<sub>C</sub>&gt;T<sub>C,tr</sub>,</i>, the value of <i>T<sub>C</sub></i> is <i>T<sub>CE</sub></i>. If <i>T<sub>C</sub>&lt;T<sub>C,tr</sub>, T<sub>C</sub></i> is equal to<i> T<sub>Cl</sub></i>. When <i>T<sub>S</sub>&gt;T<sub>C,tr</sub>, </i>the value of <i>T<sub>S</sub></i> is <i>T<sub>Sl</sub>. </i>When <i>T<sub>S</sub>&lt;T<sub>C,tr</sub>, T<sub>S</sub></i> is equal to <i>T<sub>SE</sub></i>. Unstable operation area is located between the critical and stable ignition and extinction temperatures. High <i>hS </i>values are recommended in order to assure operation at stable area. Thus, for an analogous parameter, UA, Fogler (2008) (UA = 126.6 kJ/(min.K)) and Moln&aacute;r <i>et al., </i>(2003) (UA = 240 kJ/(min.K)) guaranteed in their analysis that the removed heat will be higher than the generated one. However, no explanation related to the selection of these values was included. From the results of this study, it is possible to argue that in order to work in the stable low temperature area (<i>T<sub>Sl</sub></i>), the <i>hS </i>values should be higher than 9.38 kJ/(min.K).</p>     <p align="center"><a name="f3"><img src="img/revistas/iei/v35n2/v35n2a09f3.jpg"></a></p>      ]]></body>
<body><![CDATA[<p><b>Conclusions</b></p>     <p>A new method for the analysis of a steady state and safety operational conditions of the hydrolysis of propylene oxide to propylene glycol in a CSTR was developed. Thus, the existence of multiple stable states was recognized when the parameter <i>hS, </i>related to the reactor heat exchange, was in the range of 6.636 &lt; <i>hS kJ/(min.K) </i>&lt; 11.125.</p>     <p>The effect of feed temperature on the critical and stable ignition and extinction temperature locus was also considered and the transition point was calculated. This point separates the stable working area from the unstable one and allows defining different operational conditions. Unstable operation area was located between <i>T<sub>Cl</sub></i> and <i>T<sub>CE</sub></i>, indicating that the operating point should be in the external area and under the vaporization temperature of propylene oxide. It restricts the reactor operation area to the stable low temperatures.</p>     <p align="center"><a name="no1"><img src="img/revistas/iei/v35n2/v35n2a09no1.jpg"></a></p> <hr>     <p><b>References</b></p>     <!-- ref --><p>Bilous, O. &amp; Amundson, N. R. (1956). Chemical Reactor Stability. <i>AlChE Journal, 2, </i>pp.117-126. DOI: 10.1002/aic.690020124.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000068&pid=S0120-5609201500020000900001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>Fogler, H.S. (2008). <i>Elementos de ingenier&iacute;a de las reacciones qu&iacute;micas </i>(4ta Ed.) Pearson Education.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000070&pid=S0120-5609201500020000900002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>Kamenetskii, F. (1969). <i>Diffusion and Heat Transfer in Chemical Kinetic </i>(2da Ed.). P. Press, ed., New York.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000072&pid=S0120-5609201500020000900003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>Luo, K. M. et al. (2000). The critical runaway condition and stability criterion in the phenol-formaldehyde reaction. <i>Journal of Loss Prevention in the Process Industries, 13(2), </i>pp.91-108. DOI: 10.1016/S0950-4230(99)00071-6.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000074&pid=S0120-5609201500020000900004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>Moln&aacute;r, A., Markos, J. &amp; Jelemensky, L. (2003). Safety analysis of CSTR towards changes in operating conditions. <i>Journal of Loss Prevention in the Process Industries, 16, </i>pp.373380. DOI: 10.1016/S0950-4230(03)00069-X.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000076&pid=S0120-5609201500020000900005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>Ojeda, J. C. et al. (2014). An&aacute;lisis de la Sensibilidad Param&eacute;trica del Proceso de Producci&oacute;n de Ciclo-Trimetileno-Triamina. <i>Informaci&oacute;n tecnol&oacute;gica, 25(4), </i>pp.153-162. DOI: 10.4067/S0718-07642014000400017.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000078&pid=S0120-5609201500020000900006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>Semenov, N. N. (1928). Zur Theorie des Verbrennungsprozes-ses. Zeitschrift fur Physik, 48(7-8), pp.571-582. DOI: 10.1007/BF01340021.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000080&pid=S0120-5609201500020000900007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>&Scaron;vandov&aacute;, Z. et al. (2005). Steady States Analysis and Dynamic Simulation as a Complement in the Hazop Study of Chemical Reactors. <i>Process Safety and Environmental Protection, 83(5), </i>pp.463-471. DOI: 10.1205/psep.04262.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000082&pid=S0120-5609201500020000900008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>The Dow Chemical Company. (2011). Hoja de datos t&eacute;cnicos.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000084&pid=S0120-5609201500020000900009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>     <!-- ref --><p>Vadapalli, A. &amp; Seader, J. D. (2001). A generalized framework for computing bifurcation diagrams using process simulation programs. <i>Computers &amp; Chemical Engineering, 25, </i>pp.445-464. DOI: 10.1016/S0098-1354(01)00624-X.    &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=000086&pid=S0120-5609201500020000900010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --></p>  </font>      ]]></body><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bilous]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Amundson]]></surname>
<given-names><![CDATA[N. R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Chemical Reactor Stability]]></article-title>
<source><![CDATA[AlChE Journal]]></source>
<year>1956</year>
<volume>2</volume>
<page-range>117-126</page-range></nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fogler]]></surname>
<given-names><![CDATA[H.S]]></given-names>
</name>
</person-group>
<source><![CDATA[Elementos de ingeniería de las reacciones químicas]]></source>
<year>2008</year>
<edition>4</edition>
<publisher-name><![CDATA[Pearson Education]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kamenetskii]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<source><![CDATA[Diffusion and Heat Transfer in Chemical Kinetic]]></source>
<year>1969</year>
<edition>2</edition>
<publisher-loc><![CDATA[New York ]]></publisher-loc>
<publisher-name><![CDATA[P. Press, ed]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Luo]]></surname>
<given-names><![CDATA[K. M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The critical runaway condition and stability criterion in the phenol-formaldehyde reaction]]></article-title>
<source><![CDATA[Journal of Loss Prevention in the Process Industries]]></source>
<year>2000</year>
<volume>13</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>91-108</page-range></nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Molnár]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Markos]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Jelemensky]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Safety analysis of CSTR towards changes in operating conditions]]></article-title>
<source><![CDATA[Journal of Loss Prevention in the Process Industries]]></source>
<year>2003</year>
<volume>16</volume>
<page-range>373-380</page-range></nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ojeda]]></surname>
<given-names><![CDATA[J. C]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Análisis de la Sensibilidad Paramétrica del Proceso de Producción de Ciclo-Trimetileno-Triamina]]></article-title>
<source><![CDATA[Información tecnológica]]></source>
<year>2014</year>
<volume>25</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>153-162</page-range></nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Semenov]]></surname>
<given-names><![CDATA[N. N]]></given-names>
</name>
</person-group>
<article-title xml:lang="de"><![CDATA[Zur Theorie des Verbrennungsprozes-ses]]></article-title>
<source><![CDATA[Zeitschrift fur Physik]]></source>
<year>1928</year>
<volume>48</volume>
<numero>7-8</numero>
<issue>7-8</issue>
<page-range>571-582</page-range></nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[&#352;vandová]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Steady States Analysis and Dynamic Simulation as a Complement in the Hazop Study of Chemical Reactors]]></article-title>
<source><![CDATA[Process Safety and Environmental Protection]]></source>
<year>2005</year>
<volume>83</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>463-471</page-range></nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="book">
<source><![CDATA[The Dow Chemical Company]]></source>
<year>2011</year>
<publisher-name><![CDATA[Hoja de datos técnicos]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vadapalli]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Seader]]></surname>
<given-names><![CDATA[J. D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A generalized framework for computing bifurcation diagrams using process simulation programs]]></article-title>
<source><![CDATA[Computers & Chemical Engineering]]></source>
<year>2001</year>
<volume>25</volume>
<page-range>445-464</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>